I want to search for...

Permit #2024071039

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00470-0180
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00470
Subdivision: 7032 -
Job Phone: 689-250-2429
Location Address: 74 ROXBORO DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/31/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0180
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 07/10/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/7/2025 - PREVIOUS INSPECTION NOTES NEED TO FIX WASH OUTS IN THE FRONT AND CLEAN DIRT OUT OF CULVERT PIPE --------------------------------------------------------------------- 07/03/25 TPOLACEK*** UPON WALKING PROPERTY FOUND WASHOUTS ALONG RIGHT SIDE OF DRIVEWAY INTO SWALE. THESE WASHOUTS MUST BE REESTABLISHED AND ALL SEDIMENT IN CULVERT MUST BE REMOVED. APPROVING FIELD AS NOTED AND WILL NOTE FINAL STORMWATER.
ROW - STORMWATER FINAL 07/07/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO FIX WASH OUTS IN THE FRONT AND CLEAN DIRT OUT OF CULVERT PIPE --------------------------------------------------------------------- 07/03/25 TPOLACEK*** UPON WALKING PROPERTY FOUND WASHOUTS ALONG RIGHT SIDE OF DRIVEWAY INTO SWALE. THESE WASHOUTS MUST BE REESTABLISHED AND ALL SEDIMENT IN CULVERT MUST BE REMOVED. APPROVING FIELD AS NOTED AND WILL NOTE FINAL STORMWATER.
ROW - FINAL APRON (AFTER POUR) 07/07/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/03/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 07/03/2025 APPROVED - AS NOTED TPOLACEK
Note: 07/03/25 TPOLACEK*** UPON WALKING PROPERTY FOUND WASHOUTS ALONG RIGHT SIDE OF DRIVEWAY INTO SWALE. THESE WASHOUTS MUST BE REESTABLISHED AND ALL SEDIMENT IN CULVERT MUST BE REMOVED. APPROVING FIELD AS NOTED AND WILL NOTE FINAL STORMWATER.
BLD - BUILDING FINAL 07/02/2025 APPROVED CVANSTRAHLEN
Note:
BLD - BUILDING FINAL 06/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please removed porta potty and trash from driveway FBC [A]107.4 -NOT READY - WORK INCOMPLETE Building is all good , trash in driveway wood and pallet need to be removed
ROW- PRE-APRON (PRE-POUR) 06/10/2025 APPROVED - AS NOTED TPOLACEK
Note: 06/10/25 TPOLACEK*** BUILDER MUST DIG OUT FOOTER BEFORE POURING. INSPECTOR WILL CHECK WITH PROBE TO ENSURE FOOTER IS PRESENT ON AFTER POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 6/3/2025 - PREVIOUS INSPECTION NOTES 06/03/25 TPOLACEK*** UPPER PORTION OF DRIVEWAY HAS WASHED DOWN OVER TOP OF CULVERT. CULVERT PIPE SHALL BE SET IN ACCORDANCE WITH THE RESIDENTIAL CULVERT DIAGRAM. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" ALSO SEE PHOT
ROW- PRE-APRON (PRE-POUR) 06/03/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 06/03/25 TPOLACEK*** UPPER PORTION OF DRIVEWAY HAS WASHED DOWN OVER TOP OF CULVERT. CULVERT PIPE SHALL BE SET IN ACCORDANCE WITH THE RESIDENTIAL CULVERT DIAGRAM. * RESIDENTIAL CONCRETE DRIVEWAY CULVERT DETAIL DRAWING 300. E "CULVERT TO BE CENTERED ON DRIVEWAY. CULVERT SHALL BE CONCRETE ENCASED TO SPRING LINE AND AT LEAST 12"" ON EACH SIDE SEE SECTION B-B. Sec 300.E" ALSO SEE PHOT
ELECTRIC - EARLY POWER 05/21/2025 APPROVED CVANSTRAHLEN
Note: Please keep colvert pipe of neighborh yard
ELECTRIC - EARLY POWER 05/14/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-NEC 110.27-SAFE OFF ALL WIRING ( share baedroom celing light , smoke detectors for share bedroom Front , hallway sahre badrroms , entrance by master bedroom smoke detector ) #2- trash need to be pick up , tires , carboard, plywood , plastic etc etc , please keep contrucction side posible clean 5/13/2025 - PREVIOUS INSPECTION NOTES Please pick up trash , tires around building exterior
GRAVITY SEWER TEST 05/13/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 05/13/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: Doors lock FBC[A] 110.5-ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Please pick up trash , tires around building exterior
U-CROSS CONNECTION 05/13/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
U - SEWER TIE IN 05/13/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION
LATH/BRICK/ WATER BARRIER 04/16/2025 APPROVED CVANSTRAHLEN
LATH/BRICK/ WATER BARRIER 04/07/2025 Disapproved - NO FEE CVANSTRAHLEN
Note: work is not done
INSULATION 04/04/2025 APPROVED CVANSTRAHLEN
ALL ROUGH 03/31/2025 APPROVED CVANSTRAHLEN
Note:
ALL ROUGH 03/26/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: previous item 3 and 4 not solve . please fix items before next inspection 3/25/2025 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #3-Missing E-call for inspection , need document for inspection , missing duct work lay-out for inspection #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - water level is low , fill with water
ALL ROUGH 03/25/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 3/25/2025 12:07:50 PM *** #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - not water Please fix items before next inspection #1-please fix hole in cilender block where water line for refrigerator is #2- missing Fl Approval document , Need document for inspection #3-Missing E-call for inspection , need document for inspection
ROOF VALLEY & METAL 03/07/2025 APPROVED CVANSTRAHLEN
WALL SHEATHING 02/26/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2340 11/18/24 will check on next inspection FBCR 606.3.1-HEAD AND BED JOINT LIMITS ( mark on plans ) Trash need to be in dumpster ( Clean up Area )
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/26/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 2/26/25 Noting alot of concrete pad cracks throughout the home already Inspector Notes from Inspection 2340 11/18/24 will check on next inspection FBCR 606.3.1-HEAD AND BED JOINT LIMITS ( mark on plans ) Trash need to be in dumpster ( Clean up Area )
FOUND SURVEY APPROVED (OFFICE) 02/25/2025 APPROVED TDOAK
TIE BEAM / LINTEL 11/18/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: 11/18/24 will check on next inspection FBCR 606.3.1-HEAD AND BED JOINT LIMITS ( mark on plans ) Trash need to be in dumpster ( Clean up Area )
MONOLITHIC SLAB 10/22/2024 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 10/04/2024 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 10/01/2024 CANCELLED BY APPLICANT WEB
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/26/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 09/19/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 06/13/2025 06/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 05/16/2025 05/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/14/2025 05/16/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload
SW1 COMPLETE 02/18/2025 02/18/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/18/2025 02/18/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/18/2025 02/18/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH COMPLETE 12/20/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 12/05/2024 12/09/2024
Note: Held By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM Slab elevation is more than 10" lower than adjacent home.
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/05/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 11/14/2024 11/20/2024
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM FFE is outside of the 10" tolerance to the adjacent house. Proposed and approved FFE of 36.0' was just at the tolerance, the poured FFE of 35.82' is too low.
ZON COMPLETE 11/14/2024 11/14/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 09/23/2024 09/26/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 09/23/2024 09/23/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future submittals, 1st report - Geo Tech Report 2nd report- Geo Tech CERTIFICATION
BADMIN COMPLETE 08/28/2024 09/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/29/2024 07/29/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON COMPLETE 07/29/2024 07/29/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 HOLD 07/29/2024 07/29/2024
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/29/2024 07/29/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/29/2024 07/29/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 07/22/2024 07/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 07/22/2024 07/23/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/22/2024 07/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/22/2024 07/23/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
ZON HOLD 07/22/2024 07/25/2024
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plan need to have both flood map panel numbers listed on it as well as the survey
MECH COMPLETE 07/22/2024 07/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 07/22/2024 11/05/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/10/2025
REINSPECTION RESIDENTIAL ¤40.00 07/10/2025
REINSPECTION RESIDENTIAL ¤40.00 07/10/2025
REINSPECTION RESIDENTIAL ¤40.00 07/10/2025
REINSPECTION RESIDENTIAL ¤40.00 07/10/2025
SW ENG REINSPECTION 20 ¤20.00 07/10/2025
SW ENG REINSPECTION 30 ¤30.00 07/10/2025
SW ENG - REVIEW 20 ¤20.00 07/31/2024
SW ENG RES REVIEW 200 ¤200.00 07/31/2024
SEWER CREDIT (¤2,572.01) 07/31/2024
SEWER INSPECTION ¤25.00 07/31/2024
SEWER CAPITAL FACILITY ¤6,120.52 07/31/2024
WATER CREDIT (¤74.81) 07/31/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 07/31/2024
SITE PLAN 30 ¤30.00 07/31/2024
WATER- TURN ON ¤25.00 07/31/2024
ADJUSTMENT 50% (¤342.60) 07/31/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/31/2024
INSPECTION - RESIDENTIAL ¤572.00 07/31/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 07/31/2024
CONNECTION FEES ¤1,187.26 07/31/2024
FC IMPACT FEE EMS ¤62.00 07/31/2024
IMPACT FEE FIRE ¤428.09 07/31/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/31/2024
FC IMPACT FEE LIBRARY ¤268.00 07/31/2024
IMPACT FEE PARKS ¤1,800.99 07/31/2024
IMPACT FEE SCHOOL ¤5,450.00 07/31/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/31/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/31/2024
SURCHARGE FS 533.721 ¤3.43 07/31/2024
SURCHARGE - FS 468.631 ¤5.14 07/31/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/31/2024
SW ENG INSPECTION 80 ¤80.00 07/31/2024
SW ENG PRE APRON ¤30.00 07/31/2024
Fees Total Due: ¤0.00 Total Paid: ¤20,149.85