I want to search for...
Permit #2024071072
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00040-0040 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00040 |
| Subdivision: - |
| Job Phone: 689-250-2429 |
| Location Address: 9 PHILMONT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/31/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address SUITE 207 MAITLAND, FL 32751 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/22/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/22/2025 11:04:00 AM *** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: 1). Front hose bibb is missing anti-siphon device. FBC-P2902.4.3 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection. | |||
| BLD - BUILDING FINAL | 05/20/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/20/2025 3:44:49 PM *** 5/20/25: 1). Front hose bibb is missing anti-siphon device. FBC-P2902.4.3 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 05/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED. | |||
| ROW - STORMWATER FINAL | 05/16/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED nspector Notes from Inspection 9465 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED. | |||
| BLD - BUILDING FINAL | 05/09/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/9/2025 4:32:44 PM *** 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/08/2025 | APPROVED | FSLADISH |
| Note: 4/30/2025 - PREVIOUS INSPECTION NOTES 04/30/25 TPOLACEK*** FINAL SURVEY SHOWS THE FRONT SWALE STILL DOES NOT HAVE POSITIVE FALL IN THE DIRECTION SHOWN ON SWALE PLAN DIAGRAM. THERE IS A 1' RISE FROM THE CULVERT TO THE PROPERTY LINE. INSPECTOR WENT ON SITE TO CONFIRM AND SWALE IS BACK PITCHED AND WILL HOLD WATER. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/08/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/30/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/30/25 TPOLACEK*** FINAL SURVEY SHOWS THE FRONT SWALE STILL DOES NOT HAVE POSITIVE FALL IN THE DIRECTION SHOWN ON SWALE PLAN DIAGRAM. THERE IS A 1' RISE FROM THE CULVERT TO THE PROPERTY LINE. INSPECTOR WENT ON SITE TO CONFIRM AND SWALE IS BACK PITCHED AND WILL HOLD WATER. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/24/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan | |||
| ROW- PRE-APRON (PRE-POUR) | 03/28/2025 | APPROVED | TPOLACEK |
| Note: 03/28/25 TPOLACEK*** CORRECTIONS MADE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/27/2025 - PREVIOUS INSPECTION NOTES 03/27/25 TPOLACEK*** APRON WING ON RIGHT IS STILL NOT 36" FROM LEADING EDGE OF DRIVEWAY. PLEASE RESET APRON WING ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO | |||
| ROW- PRE-APRON (PRE-POUR) | 03/27/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 03/27/25 TPOLACEK*** APRON WING ON RIGHT IS STILL NOT 36" FROM LEADING EDGE OF DRIVEWAY. PLEASE RESET APRON WING ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO | |||
| ROW- PRE-APRON (PRE-POUR) | 03/26/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO | |||
| ELECTRIC - EARLY POWER | 03/07/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/7/2025 10:27:33 AM *** 3/7/25: FPL emailed to release power. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection. | |||
| GRAVITY SEWER TEST | 03/06/2025 | APPROVED | MGIBSON |
| U-CROSS CONNECTION | 03/06/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connection | |||
| U - SEWER TIE IN | 03/06/2025 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 01/31/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 01/14/2025 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2420 1. CPVC in laundry room must be sealed @ slab FBCR 402.4.1.1 2. Duct work supplying middle spare bedroom has sag and must be supported FBCR M1601.4.4 3. Failed 5' head pressure test FBCR P2503.7 Have all repairs made by insulation | |||
| ALL ROUGH | 01/08/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. CPVC in laundry room must be sealed @ slab FBCR 402.4.1.1 2. Duct work supplying middle spare bedroom has sag and must be supported FBCR M1601.4.4 3. Failed 5' head pressure test FBCR P2503.7 Have all repairs made by insulation | |||
| LATH/BRICK/ WATER BARRIER | 12/26/2024 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 12/20/2024 | APPROVED | KSANDOE |
| ROOF VALLEY & METAL | 12/13/2024 | APPROVED | PKNAPIK |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/21/2024 | APPROVED | CVANSTRAHLEN |
| FOUND SURVEY APPROVED (OFFICE) | 11/18/2024 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 11/13/2024 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection 11/8/2024 - PREVIOUS INSPECTION NOTES 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3 | |||
| TIE BEAM / LINTEL | 11/12/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 11/8/2024 - PREVIOUS INSPECTION NOTES 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3 | |||
| TIE BEAM / LINTEL | 11/08/2024 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/8/2024 11:42:51 AM *** 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3 | |||
| MONOLITHIC SLAB | 10/15/2024 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3 | |||
| MONOLITHIC SLAB | 10/07/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/7/2024 9:53:09 AM *** 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/01/2024 | APPROVED | MGIBSON |
| Note: 9/30/2024 - PREVIOUS INSPECTION NOTES FBC[A], 107.3.1 NEED APPROVED STAMPED PLANS ON SITE | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/30/2024 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: FBC[A], 107.3.1 NEED APPROVED STAMPED PLANS ON SITE | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/23/2024 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 08/16/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/16/2025 | 05/19/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/14/2025 | 05/16/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload | |||
| BADMIN | INFORMATION | 04/28/2025 | 04/28/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM We are unable to process due to expired liability insurance. Please resubmit the final survey to be processed once the liability has been submitted and updated. | |||
| MECH | COMPLETE | 12/18/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/19/2024 | 11/22/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/12/2024 | 11/18/2024 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/12/2024 | 11/12/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/17/2024 | 09/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/28/2024 | 09/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/29/2024 | 07/29/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | COMPLETE | 07/29/2024 | 07/29/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 07/22/2024 | 07/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/22/2024 | 07/23/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/22/2024 | 07/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/22/2024 | 07/24/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/22/2024 | 07/24/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please provide driveway apron width at edge of pavement | |||
| ZON | COMPLETE | 07/22/2024 | 07/26/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/22/2024 | 07/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 07/22/2024 | 11/05/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/22/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 05/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/22/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 05/22/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 05/22/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/15/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/15/2024 |
| CONNECTION FEES | ¤1,187.26 | 07/31/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 07/31/2024 |
| IMPACT FEE FIRE | ¤428.09 | 07/31/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/31/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/31/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 07/31/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/31/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 07/31/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/31/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 07/31/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 07/31/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/31/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/31/2024 |
| SW ENG PRE APRON | ¤30.00 | 07/31/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/31/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/31/2024 |
| SEWER CREDIT | (¤829.14) | 07/31/2024 |
| SEWER INSPECTION | ¤25.00 | 07/31/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 07/31/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 07/31/2024 |
| SITE PLAN 30 | ¤30.00 | 07/31/2024 |
| WATER- TURN ON | ¤25.00 | 07/31/2024 |
| ADJUSTMENT 50% | (¤342.60) | 07/31/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/31/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 07/31/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 07/31/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,970.03 |