I want to search for...

Permit #2024071072

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00040-0040
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00040
Subdivision: -
Job Phone: 689-250-2429
Location Address: 9 PHILMONT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/31/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0040
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/22/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/22/2025 11:04:00 AM *** 5/20/2025 - PREVIOUS INSPECTION NOTES 5/20/25: 1). Front hose bibb is missing anti-siphon device. FBC-P2902.4.3 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection.
BLD - BUILDING FINAL 05/20/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/20/2025 3:44:49 PM *** 5/20/25: 1). Front hose bibb is missing anti-siphon device. FBC-P2902.4.3 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection.
ROW - FINAL APRON (AFTER POUR) 05/16/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED.
ROW - STORMWATER FINAL 05/16/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED nspector Notes from Inspection 9465 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED.
BLD - BUILDING FINAL 05/09/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/9/2025 4:32:44 PM *** 5/9/25: NOT READY! TOO MANY ITEMS TO LIST ALL! A FULL RE-INSPECTION WILL BE REQUIRED! PLEASE WALK YOUR HOUSE IN ENTIRETY TO ASSURE FULL CODE COMPLINCE BEFORE RE-SCHEDULING INSPECTION. EXAMPLES ONLY! 1). Installed equipment does not match Energy Calcs submitted and approved. (Revision including changed model numbers required). FBC [A] 107.4 2). Water Heater pan drain is trapped above pan flood level lip. FBC [A] 107.4 3). Insulation certificate is not posted in attic as required. FBC EC R303.1.1.2 4). Range anti-tip bracket is not anchored as required by Manufacturer. FBC [A] 107.4 5). Guest bathroom: Tile is not sealed in the corner and at the tub as required. ( FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight.) 6). Pep tank breaker is not GFCI. NEC-422.5(A)(6) 7). Garage light is not rated for installation in a garage area. NEC-410.116(C) 8). Interior dryer exhaust pipe needs to be capped, plugged (or taped) as required by FBC-M1502.4.7 9). Garage door safety eyes are too low. Between 2" and 6" to Eye Centerline as required. UL 325.6 / 16CFR part 1211 10). Kitchen wall outlet must be GFCI protected. NEC 210.8(A)(7) [must not be added to small appliance circuit NEC-210.52(B)(2) / NEC-210.52(C)(3)(3)] 3/7/25: From Early Power Inspection. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/08/2025 APPROVED FSLADISH
Note: 4/30/2025 - PREVIOUS INSPECTION NOTES 04/30/25 TPOLACEK*** FINAL SURVEY SHOWS THE FRONT SWALE STILL DOES NOT HAVE POSITIVE FALL IN THE DIRECTION SHOWN ON SWALE PLAN DIAGRAM. THERE IS A 1' RISE FROM THE CULVERT TO THE PROPERTY LINE. INSPECTOR WENT ON SITE TO CONFIRM AND SWALE IS BACK PITCHED AND WILL HOLD WATER. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan
ROW FIELD SURVEY /GRADING CERTIFICATION 05/08/2025 APPROVED - AS NOTED FSLADISH
Note: 5/8/25 PER MY CONVERSATION WITH INSPECTOR POLACHEK AND HIS DISCUSSION WITH JOEY THE GRADER I AM GOING TO PASS THIS FIELD SURVEY, BUT THERE MAY BE SOME ADDITIONAL GRADE WORK NEEDED IN THE REAR RIGHT CORNER. THEY ARE BUILDING A POOL NEXT DOOR AND THE POOL BUILDER WILL BE RESPONSIBLE FOR ANY RAPAIR/ REGRADING NECCESSARY TO REGAIN POSITIVE FLOW ON THE LEFT SIDE PROPERTY LINE DRAINAGE CONVEYANCE. APPROVING AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/30/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/30/25 TPOLACEK*** FINAL SURVEY SHOWS THE FRONT SWALE STILL DOES NOT HAVE POSITIVE FALL IN THE DIRECTION SHOWN ON SWALE PLAN DIAGRAM. THERE IS A 1' RISE FROM THE CULVERT TO THE PROPERTY LINE. INSPECTOR WENT ON SITE TO CONFIRM AND SWALE IS BACK PITCHED AND WILL HOLD WATER. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/24/2025 Disapproved - NO FEE TPOLACEK
Note: 04/24/25 TPOLACEK*** FINAL SURVEY INDICATES THE FRONT SWALE DOES NOT HAVE POSITIVE FALL IN THE DIRECTION DESCRIBED IN THE SWALE PLAN DIAGRAM. Finished Floor Elevations (FFE): ROADSIDE SWALE AND CULVERT Section 300.01 C(1) V-17 1) The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 of a foot and must demonstrate positive fall in the direction described in the swale plan
ROW- PRE-APRON (PRE-POUR) 03/28/2025 APPROVED TPOLACEK
Note: 03/28/25 TPOLACEK*** CORRECTIONS MADE. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/27/2025 - PREVIOUS INSPECTION NOTES 03/27/25 TPOLACEK*** APRON WING ON RIGHT IS STILL NOT 36" FROM LEADING EDGE OF DRIVEWAY. PLEASE RESET APRON WING ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO
ROW- PRE-APRON (PRE-POUR) 03/27/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 03/27/25 TPOLACEK*** APRON WING ON RIGHT IS STILL NOT 36" FROM LEADING EDGE OF DRIVEWAY. PLEASE RESET APRON WING ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO
ROW- PRE-APRON (PRE-POUR) 03/26/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 03/26/25 TPOLACEK*** ALL FORM BOARDS NEED TO EXTEND TO THE GROUND OR BE BACKFILLED TO PREVENT OVER POUR. APRON WINGS SHALL BE 36" FROM EDGE OF DRIVEWAY EXTANDING OUT AS SHOWN IN RESIDENTIAL CULVERT DIAGRAM. SEE ATTACHED PHOTO
ELECTRIC - EARLY POWER 03/07/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/7/2025 10:27:33 AM *** 3/7/25: FPL emailed to release power. 1). Hole in wall at Range outlet exposing romex will need to be repaired prior to Building Final Inspection.
GRAVITY SEWER TEST 03/06/2025 APPROVED MGIBSON
U-CROSS CONNECTION 03/06/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
U - SEWER TIE IN 03/06/2025 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 01/31/2025 APPROVED CBOWERMASTER
INSULATION 01/14/2025 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 1. CPVC in laundry room must be sealed @ slab FBCR 402.4.1.1 2. Duct work supplying middle spare bedroom has sag and must be supported FBCR M1601.4.4 3. Failed 5' head pressure test FBCR P2503.7 Have all repairs made by insulation
ALL ROUGH 01/08/2025 APPROVED - AS NOTED MKRASKI
Note: 1. CPVC in laundry room must be sealed @ slab FBCR 402.4.1.1 2. Duct work supplying middle spare bedroom has sag and must be supported FBCR M1601.4.4 3. Failed 5' head pressure test FBCR P2503.7 Have all repairs made by insulation
LATH/BRICK/ WATER BARRIER 12/26/2024 APPROVED CVANSTRAHLEN
WALL SHEATHING 12/20/2024 APPROVED KSANDOE
ROOF VALLEY & METAL 12/13/2024 APPROVED PKNAPIK
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/21/2024 APPROVED CVANSTRAHLEN
FOUND SURVEY APPROVED (OFFICE) 11/18/2024 APPROVED JMYERS
TIE BEAM / LINTEL 11/13/2024 APPROVED RSIMS
Note: New inspection due to canceled inspection 11/8/2024 - PREVIOUS INSPECTION NOTES 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3
TIE BEAM / LINTEL 11/12/2024 CANCELLED BY APPLICANT WEB
Note: 11/8/2024 - PREVIOUS INSPECTION NOTES 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3
TIE BEAM / LINTEL 11/08/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 11/8/2024 11:42:51 AM *** 11/8/24: 1). Down rod at the right side front entry does not meet the minimum clearance (2" from face of block) as required. (FBC-R606.3.4) Spray painted orange on CMU. Inspector Notes from Inspection 2250 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3
MONOLITHIC SLAB 10/15/2024 APPROVED - AS NOTED CVANSTRAHLEN
Note: 10/15/24 Approved as-note ( C Van-Strahlen ) please have permit sheet and full set of plans documents for next inspection incluid termited bond 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3
MONOLITHIC SLAB 10/07/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 10/7/2024 9:53:09 AM *** 10/7/24: 1). Dirt cave-in/wash-in needs to be cleaned out. FBC[A] 107.4 2). Root in right side footer needs to be removed. FBC[A] 107.4 3). Pipe sleeve for main drain needs to extend fully through the footer. FBC-R305.3
PLUMBING 1ST ROUGH UNDERGROUND 10/01/2024 APPROVED MGIBSON
Note: 9/30/2024 - PREVIOUS INSPECTION NOTES FBC[A], 107.3.1 NEED APPROVED STAMPED PLANS ON SITE
PLUMBING 1ST ROUGH UNDERGROUND 09/30/2024 Disapproved -FEE REQUIRED MGIBSON
Note: FBC[A], 107.3.1 NEED APPROVED STAMPED PLANS ON SITE
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 09/23/2024 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 08/16/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 05/16/2025 05/19/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/14/2025 05/16/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM File needs to be named heatload and drop down menu heatload
BADMIN INFORMATION 04/28/2025 04/28/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM We are unable to process due to expired liability insurance. Please resubmit the final survey to be processed once the liability has been submitted and updated.
MECH COMPLETE 12/18/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 12/05/2024 12/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2024 11/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/12/2024 11/18/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/12/2024 11/12/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/17/2024 09/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 08/28/2024 09/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/29/2024 07/29/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON COMPLETE 07/29/2024 07/29/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN COMPLETE 07/22/2024 07/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 07/22/2024 07/23/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/22/2024 07/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/22/2024 07/24/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 HOLD 07/22/2024 07/24/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please provide driveway apron width at edge of pavement
ZON COMPLETE 07/22/2024 07/26/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
MECH COMPLETE 07/22/2024 07/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 07/22/2024 11/05/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/22/2025
PLAN REVIEW - REVISION ¤32.50 05/22/2025
REINSPECTION RESIDENTIAL ¤40.00 05/22/2025
SW ENG REINSPECTION 30 ¤30.00 05/22/2025
SW ENG REINSPECTION 30 ¤30.00 05/22/2025
REINSPECTION RESIDENTIAL ¤40.00 10/15/2024
REINSPECTION RESIDENTIAL ¤40.00 10/15/2024
CONNECTION FEES ¤1,187.26 07/31/2024
FC IMPACT FEE EMS ¤62.00 07/31/2024
IMPACT FEE FIRE ¤428.09 07/31/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/31/2024
FC IMPACT FEE LIBRARY ¤268.00 07/31/2024
IMPACT FEE PARKS ¤1,800.99 07/31/2024
IMPACT FEE SCHOOL ¤5,450.00 07/31/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 07/31/2024
WATER -IRRIGATION INSPECTION ¤25.00 07/31/2024
SURCHARGE FS 533.721 ¤3.43 07/31/2024
SURCHARGE - FS 468.631 ¤5.14 07/31/2024
SW ENG - FOUNDATION SURVEY ¤20.00 07/31/2024
SW ENG INSPECTION 80 ¤80.00 07/31/2024
SW ENG PRE APRON ¤30.00 07/31/2024
SW ENG - REVIEW 20 ¤20.00 07/31/2024
SW ENG RES REVIEW 200 ¤200.00 07/31/2024
SEWER CREDIT (¤829.14) 07/31/2024
SEWER INSPECTION ¤25.00 07/31/2024
SEWER CAPITAL FACILITY ¤6,120.52 07/31/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 07/31/2024
SITE PLAN 30 ¤30.00 07/31/2024
WATER- TURN ON ¤25.00 07/31/2024
ADJUSTMENT 50% (¤342.60) 07/31/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/31/2024
INSPECTION - RESIDENTIAL ¤572.00 07/31/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 07/31/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,970.03