Permit #2024071318
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00720-0130 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00720 |
| Subdivision: 7025 - |
| Job Phone: 689-250-2429 |
| Location Address: 42 PALM LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/05/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A LAND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE 207 MAITLAND, FL 32751 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/31/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 7/31/2025 11:46:04 AM *** 7/25/2025 - PREVIOUS INSPECTION NOTES 7/25/25: 1). Updated Energy Calcs on site are incomplete. Missing model number page, etc. / previous energy calcs do not match model numbers. FBC [A] 107.4 __________________________________________________________________________________________________________________________ 6/26/25: Check for repair of wall opening at range romex feed as seen during Early Power Inspection. | |||
| BLD - BUILDING FINAL | 07/25/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 7/25/2025 1:10:40 PM *** 7/25/25: 1). Updated Energy Calcs on site are incomplete. Missing model number page, etc. / previous energy calcs do not match model numbers. FBC [A] 107.4 __________________________________________________________________________________________________________________________ 6/26/25: Check for repair of wall opening at range romex feed as seen during Early Power Inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 07/21/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9465 07/21/25 TPOLACEK*** UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION THERE WAS NO STANDING OR POOLING WATER. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/21/2025 | APPROVED | TPOLACEK |
| Note: 07/21/25 TPOLACEK*** FINAL SURVEY MEETS ALL COPC MINIMUM STANDARDS 07/11/25 TPOLACEK***INSPECTOR NOTE**** PLEASE SEE PROJECT STATUS NOTES WHEN REVIEWING FINAL SURVEY. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/21/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 07/21/25 TPOLACEK*** UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION THERE WAS NO STANDING OR POOLING WATER. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 07/21/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- PROJECT STATUS | 07/11/2025 | Status Check | TPOLACEK |
| Note: 07/11/25 TPOLACEK*** MET ON SITE WITH GRADER, CM (JASON) INSPECTORS BERTOLA,& SLADISH. ELEVATION SHOTS ALONG ADJOINNG PROPERTY WERE TAKEN TO MAKE SURE BUILDER DOES NOT IMPACT ADJOINING LOT. BUILDER HAS CREATED THE MINIMUM COPC STANDARDS FOR DRAINAGE AT THIS TIME. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/27/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/24/2025 - PREVIOUS INSPECTION NOTES 06/24/25 TPOLACEK*** AT THIS TIME CULVERT IS SET PROPERLY HOWEVER THE FORM BOARDS NEED TO BE SET IN PLACE AND THE SLOPE ON THE RIGHT SIDE EXCEEDS THE MAX 8% . PLEASE HAVE FORMS REESTABLISHED AND RESUBMIT REQUEST. SEE PHOTOS Inspector Notes from Inspection 9470 04/17/25 TPOLACEK**** GRADER IS ON SITE REMOVING CONCRETE AT THE TIME OF INSPECTION. BUILDER MUST MAINTAIN SWALE AND SITE THROUGHOUT THE ENTIRE BUILD PROCESS. 4/16/2025 - PREVIOUS INSPECTION NOTES 04/16/25 TPOLACEK*** BUILDER WAS GIVEN 5 DAYS TO CLEAN UP ILLICIT DISCHARGE. IF NOT CLEANED UP BY TOMORROW 04/17/25 PERMIT WILL BE PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** BUILDER MUST REMOVE ALL OVER POUR CONCRETE THROUGHOUT LOT THIS IS CONCIDERED AN ILLICIT DISCHARGE AND MUST BE REMOVED WITHIN 5 DAYS OF THIS INSPECTION. BUILDER WILL ALSO NEED TO OPEN SWALE AS THERE ARE DEVIATIONS IN GRADE AND DRAINAGE WILL NOT FLOW CORRECTLY. NEXT INSPECTION WILL BE 4/16/25 | |||
| ELECTRIC - EARLY POWER | 06/26/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/26/2025 9:06:40 AM *** 6/26/25: FPL emailed to release power. 1). Check for repair of wall opening at range romex feed during Building Final Inspection. 6/24/2025 - PREVIOUS INSPECTION NOTES 6/24/25: 1). Missing Surge Protector at Main Meter Panel as required. NEC-230.67(A)/(B) | |||
| ELECTRIC - EARLY POWER | 06/24/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/24/2025 11:20:45 AM *** 6/24/25: 1). Missing Surge Protector at Main Meter Panel as required. NEC-230.67(A)/(B) | |||
| ROW- PRE-APRON (PRE-POUR) | 06/24/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 06/24/25 TPOLACEK*** AT THIS TIME CULVERT IS SET PROPERLY HOWEVER THE FORM BOARDS NEED TO BE SET IN PLACE AND THE SLOPE ON THE RIGHT SIDE EXCEEDS THE MAX 8% . PLEASE HAVE FORMS REESTABLISHED AND RESUBMIT REQUEST. SEE PHOTOS Inspector Notes from Inspection 9470 04/17/25 TPOLACEK**** GRADER IS ON SITE REMOVING CONCRETE AT THE TIME OF INSPECTION. BUILDER MUST MAINTAIN SWALE AND SITE THROUGHOUT THE ENTIRE BUILD PROCESS. 4/16/2025 - PREVIOUS INSPECTION NOTES 04/16/25 TPOLACEK*** BUILDER WAS GIVEN 5 DAYS TO CLEAN UP ILLICIT DISCHARGE. IF NOT CLEANED UP BY TOMORROW 04/17/25 PERMIT WILL BE PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** BUILDER MUST REMOVE ALL OVER POUR CONCRETE THROUGHOUT LOT THIS IS CONCIDERED AN ILLICIT DISCHARGE AND MUST BE REMOVED WITHIN 5 DAYS OF THIS INSPECTION. BUILDER WILL ALSO NEED TO OPEN SWALE AS THERE ARE DEVIATIONS IN GRADE AND DRAINAGE WILL NOT FLOW CORRECTLY. NEXT INSPECTION WILL BE 4/16/25 | |||
| U-CROSS CONNECTION | 06/05/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| U - SEWER TIE IN | 06/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 06/05/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 05/05/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| INSULATION | 05/05/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| LATH/BRICK/ WATER BARRIER | 05/02/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/2/2025 10:11:47 AM *** 5/2/25: Rear wall: 1). Hole in CMU wall for A/C feed romex needs to have (minimum plastic) lath over it. FBC [A]107.4 2). Hose bibb need (minimum plastic) lath over the hole in the CMU at the top. | |||
| INSULATION | 05/01/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/1/2025 9:02:11 AM *** 5/1/25: 1). Fireblocking at top plate of guest bathroom packout wall does not meet minimum code requirements. ---> FBC-R302.11. Please remove the 3/4" pressure treated currently in place and replace with 2" nominal (1-1/2") lumber or other approved material identified in FBC-R302.11.1 | |||
| ALL ROUGH | 04/23/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/23/2025 1:51:29 PM *** 4/21/2025 - PREVIOUS INSPECTION NOTES 4/21/25: *** Previously listed item 3 remains unresolved. (FBC-[A}110.1) 3). Lineset sleeve needs to be exposed at return box in order to visually verify that it is sealed properly. FBC-R318.2 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Device boxes attached to bottom cord of truss must be accessible per NEC-314.29(A). Plans show recessed can lights. If using the shallow (puck style) cans, you will need to move the 'junction' boxes up out of the insulation and have the light (driver) whip installed and a cover on the box. 2). Dryer exhaust needs vertical support/strapping. FBC-M1502.4.2 3). Lineset sleeve needs to be exposed at return box in order to visually verify that it is sealed properly. FBC-R318.2 | |||
| ALL ROUGH | 04/21/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/21/2025 9:32:55 AM *** 4/21/25: *** Previously listed item 3 remains unresolved. (FBC-[A}110.1) 3). Lineset sleeve needs to be exposed at return box in order to visually verify that it is sealed properly. FBC-R318.2 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Device boxes attached to bottom cord of truss must be accessible per NEC-314.29(A). Plans show recessed can lights. If using the shallow (puck style) cans, you will need to move the 'junction' boxes up out of the insulation and have the light (driver) whip installed and a cover on the box. 2). Dryer exhaust needs vertical support/strapping. FBC-M1502.4.2 3). Lineset sleeve needs to be exposed at return box in order to visually verify that it is sealed properly. FBC-R318.2 | |||
| ROW - DRAINAGE | 04/17/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 04/17/25 TPOLACEK**** GRADER IS ON SITE REMOVING CONCRETE AT THE TIME OF INSPECTION. BUILDER MUST MAINTAIN SWALE AND SITE THROUGHOUT THE ENTIRE BUILD PROCESS. 4/16/2025 - PREVIOUS INSPECTION NOTES 04/16/25 TPOLACEK*** BUILDER WAS GIVEN 5 DAYS TO CLEAN UP ILLICIT DISCHARGE. IF NOT CLEANED UP BY TOMORROW 04/17/25 PERMIT WILL BE PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** BUILDER MUST REMOVE ALL OVER POUR CONCRETE THROUGHOUT LOT THIS IS CONCIDERED AN ILLICIT DISCHARGE AND MUST BE REMOVED WITHIN 5 DAYS OF THIS INSPECTION. BUILDER WILL ALSO NEED TO OPEN SWALE AS THERE ARE DEVIATIONS IN GRADE AND DRAINAGE WILL NOT FLOW CORRECTLY. NEXT INSPECTION WILL BE 4/16/25 | |||
| ROW - DRAINAGE | 04/16/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/16/25 TPOLACEK*** BUILDER WAS GIVEN 5 DAYS TO CLEAN UP ILLICIT DISCHARGE. IF NOT CLEANED UP BY TOMORROW 04/17/25 PERMIT WILL BE PLACED ON HOLD. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/11/2025 - PREVIOUS INSPECTION NOTES 04/11/25 TPOLACEK*** BUILDER MUST REMOVE ALL OVER POUR CONCRETE THROUGHOUT LOT THIS IS CONCIDERED AN ILLICIT DISCHARGE AND MUST BE REMOVED WITHIN 5 DAYS OF THIS INSPECTION. BUILDER WILL ALSO NEED TO OPEN SWALE AS THERE ARE DEVIATIONS IN GRADE AND DRAINAGE WILL NOT FLOW CORRECTLY. NEXT INSPECTION WILL BE 4/16/25 | |||
| ROW - DRAINAGE | 04/11/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/11/25 TPOLACEK*** BUILDER MUST REMOVE ALL OVER POUR CONCRETE THROUGHOUT LOT THIS IS CONCIDERED AN ILLICIT DISCHARGE AND MUST BE REMOVED WITHIN 5 DAYS OF THIS INSPECTION. BUILDER WILL ALSO NEED TO OPEN SWALE AS THERE ARE DEVIATIONS IN GRADE AND DRAINAGE WILL NOT FLOW CORRECTLY. NEXT INSPECTION WILL BE 4/16/25 | |||
| ALL ROUGH | 04/09/2025 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/9/2025 1:17:22 PM *** 4/9/25: 1). Device boxes attached to bottom cord of truss must be accessible per NEC-314.29(A). Plans show recessed can lights. If using the shallow (puck style) cans, you will need to move the 'junction' boxes up out of the insulation and have the light (driver) whip installed and a cover on the box. 2). Dryer exhaust needs vertical support/strapping. FBC-M1502.4.2 3). Lineset sleeve needs to be exposed at return box in order to visually verify that it is sealed properly. FBC-R318.2 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/03/2025 | APPROVED | JSTEWART |
| Note: 3/19/2025 - PREVIOUS INSPECTION NOTES 3/19/25: Truss inspection not complete due to unresolved deficiencies AGAIN. *** Engineer's damaged truss repair has never been submitted, reviewed or approved as requested multiple times. Please STOP re-scheduling this inspection until you have fully resolved ALL previous deficiencies. Previously listed item: 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 >>> Requested engineer's letter for trusses has not been submitted as of this inspection. Please do not schedule the re-inspection until the Engineer's letter is submitted, reviewed and APPROVED. 2/27/2025 - PREVIOUS INSPECTION NOTES 2/27/25: >> Previously listed deficiencies 1 and 3 remain unresolved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 >>> Plans are still incomplete and disconnected. New set of complete plans is required before any new inspections will be completed. 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 >>> Requested engineer's letter for trusses has not been submitted as of this inspection. Please do not schedule the re-inspection until the Engineer's letter is submitted, reviewed and APPROVED. New inspection due to canceled inspection 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Truss engineering (ONLY) has been checked & approved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 2). Trusses need to be cleaned of dirt and excessive discoloration. FBC [A]107.4 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 1/21/2025 - PREVIOUS INSPECTION NOTES 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/19/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/19/2025 1:40:02 PM *** 3/19/25: Truss inspection not complete due to unresolved deficiencies AGAIN. *** Engineer's damaged truss repair has never been submitted, reviewed or approved as requested multiple times. Please STOP re-scheduling this inspection until you have fully resolved ALL previous deficiencies. Previously listed item: 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 >>> Requested engineer's letter for trusses has not been submitted as of this inspection. Please do not schedule the re-inspection until the Engineer's letter is submitted, reviewed and APPROVED. 2/27/2025 - PREVIOUS INSPECTION NOTES 2/27/25: >> Previously listed deficiencies 1 and 3 remain unresolved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 >>> Plans are still incomplete and disconnected. New set of complete plans is required before any new inspections will be completed. 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 >>> Requested engineer's letter for trusses has not been submitted as of this inspection. Please do not schedule the re-inspection until the Engineer's letter is submitted, reviewed and APPROVED. New inspection due to canceled inspection 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Truss engineering (ONLY) has been checked & approved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 2). Trusses need to be cleaned of dirt and excessive discoloration. FBC [A]107.4 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 1/21/2025 - PREVIOUS INSPECTION NOTES 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/27/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2025 2:29:33 PM *** 2/27/25: >> Previously listed deficiencies 1 and 3 remain unresolved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 >>> Plans are still incomplete and disconnected. New set of complete plans is required before any new inspections will be completed. 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 >>> Requested engineer's letter for trusses has not been submitted as of this inspection. Please do not schedule the re-inspection until the Engineer's letter is submitted, reviewed and APPROVED. New inspection due to canceled inspection 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Truss engineering (ONLY) has been checked & approved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so that we can avoid wasting resources and time.FBC 107.2.1 2). Trusses need to be cleaned of dirt and excessive discoloration. FBC [A]107.4 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 1/21/2025 - PREVIOUS INSPECTION NOTES 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/06/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 1/24/2025 - PREVIOUS INSPECTION NOTES 1/24/25: Truss engineering (ONLY) has been checked & approved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so tat we can avoid wasting resources and time.FBC 107.2.1 2). Trusses need to be cleaned of dirt and excessive discoloration. FBC [A]107.4 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 1/21/2025 - PREVIOUS INSPECTION NOTES 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| ROOF VALLEY & METAL | 01/29/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/29/2025 2:13:33 PM *** | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/24/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/24/2025 11:41:52 AM *** 1/24/25: Truss engineering (ONLY) has been checked & approved. 1). New plans required as existing are disconnected and damaged. Please provide a set for Inspector's use only so tat we can avoid wasting resources and time.FBC 107.2.1 2). Trusses need to be cleaned of dirt and excessive discoloration. FBC [A]107.4 3). Engineer's letter verifying original truss integrity will be required due to prolonged exposure to soil and environment will be required once trusses are cleaned and prior to moving on. FBC [A]107.4 1/21/2025 - PREVIOUS INSPECTION NOTES 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| WALL SHEATHING | 01/21/2025 | CANCELLED BY INSPECTOR | MKRASKI |
| Note: Inspection not needed | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/21/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Job box is a mess clean up box and have a clean full set of stamped plans onsite along with a set of approved truss engineering packet FBC 1`07.3.1 ***Full re-inspection required*** | |||
| TIE BEAM / LINTEL | 01/10/2025 | APPROVED | MCONTRYMAN |
| FOUND SURVEY APPROVED (OFFICE) | 01/02/2025 | APPROVED | LSALYERDS |
| MONOLITHIC SLAB | 12/03/2024 | APPROVED | MCONTRYMAN |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/25/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/05/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 09/20/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/23/2025 | 07/23/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/28/2025 | 03/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 03/27/2025 | 03/27/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator Engineer letter should use the Engineer Letter document type and name it - what the doc is - Truss letter | |||
| BADMIN | CANCEL | 12/30/2024 | 01/06/2025 |
| ENGIN1 | COMPLETE | 12/30/2024 | 01/02/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/30/2024 | 12/30/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/05/2024 | 12/10/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/05/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/31/2024 | 11/05/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/18/2024 | 09/19/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/26/2024 | 08/30/2024 |
| Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PHASE 1 COMPLETE | |||
| SW1 | COMPLETE | 08/01/2024 | 08/02/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | COMPLETE | 08/01/2024 | 08/02/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/26/2024 | 07/29/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/26/2024 | 07/31/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 07/26/2024 | 07/31/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/26/2024 | 07/26/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/26/2024 | 07/26/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/26/2024 | 07/31/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/26/2024 | 07/26/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please provide driveway apron width at edge of pavement | |||
| SWALE | COMPLETE | 07/26/2024 | 10/11/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 07/31/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/31/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/31/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/31/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/31/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 07/31/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 07/31/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 07/31/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/31/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/05/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/05/2024 |
| SEWER CREDIT | (¤958.00) | 08/05/2024 |
| SEWER INSPECTION | ¤25.00 | 08/05/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 08/05/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 08/05/2024 |
| SITE PLAN 30 | ¤30.00 | 08/05/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/05/2024 |
| SW ENG PRE APRON | ¤30.00 | 08/05/2024 |
| WATER- TURN ON | ¤25.00 | 08/05/2024 |
| ADJUSTMENT 50% | (¤342.60) | 08/05/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/05/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 08/05/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 08/05/2024 |
| CONNECTION FEES | ¤1,187.26 | 08/05/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 08/05/2024 |
| IMPACT FEE FIRE | ¤428.09 | 08/05/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/05/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/05/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 08/05/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/05/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 08/05/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/05/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 08/05/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 08/05/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/05/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,878.67 |