I want to search for...

Permit #2024071443

Permit Details

Status: CANCEL

Parcel Id: 07-12-31-5580-00000-0020
Block: 00000
Subdivision: 5580 -
Job Phone: 239-673-7534
Location Address: 5055 SR 100 E
Type: IRRC - IRRIGATION COMMERCIAL
NOC: NO DOCUMENTATION
Applicant name: CARLOS ORTIZ SANCHEZ
Owner: RBSSSS LLC

Address

PO BOX 50910

JACKSONVILLE BEACH, FL 32240

Lot: 0020
Contracted Stated Job Value: ¤8,500.00
Job Description: Irrigation System Take 5
Type: CN

Contractor

AZTEC IRRIGATION & LANDSCAPING LLC
Status Location Address State License Number Phone
INACTIVE

941 SE 11TH AVENUE

CAPE CORAL, FL 33990

SCC131151685 (Exp: 08/31/2024) 239-673-7534

Inspection History

Type Request Date Result Inspector
PLUMBING 1ST ROUGH
PLUMBING 2ND ROUGH
PLUMBING FINAL
LDSC-LANDSCAPE/IRRIGATION FINAL

Review History

Department Status Date In Date Out
PLUM HOLD 08/22/2024 08/29/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. OK 2. OK 3. Repeat Comment Provide type of back flow preventer to be used (PVB, AVB, DC, RP etc.) and applicable design standard Florida Building Code-Plumbing Section 608.1, Table 608.1. 4. Repeat Comment Add testing requirements for back flow preventer. Back flow preventer to be tested at time of installation by a Florida licensed, 3rd party, back flow prevention testing agency. Back flow preventer shall be provided with "approved" inspection tag issued by testing and inspection company at time of final inspection by the City of Palm Coast. Florida Building Code-Plumbing Section 312.10.2.
PLLA HOLD 08/22/2024 08/29/2024
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Applicant shall revise plans to show: 1. P.O.C. shall be installed with PVB attached and an placed underground in a valve box with top of box flush with lawn or be area. Flloor of valve box shall have soil fabric and pea gravell ot keep out weeds and/or pests. 2. Not allowed the be installed on backflow preventer. 3. All changes in the fiels shall be coordinated with our Inspector, Larry Fitzgerald Submit revise plans with notes and revisions ,signed and sealed , by RLA or other Irrigation Professional.
PLLA HOLD 07/30/2024 08/05/2024
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM 1. Remove all notes saying "NOT FOR CONSTRUCTION" . This is a construction permit. If this is not the final plan, then submit the final plan for review. 2. Irrigation plans must be signed and sealed by either a FL Registered Landscap Architect or a Certified Florida Irrigation Professional. 3. Show and label the source of irrigation water and show what type or water is being used; Re Use? Storm Pond?, Well?
PLUM HOLD 07/30/2024 08/05/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING. 1. Plan sheets call out Take 5 Car Wash, Fort Myers, FL. Plan Sheets must identify proper site address: 5500 State Rd. 100 E., Palm Coast, FL. 32164. 2. Remove all references in Plan Sheets indicating "bid documents, not for construction" and similar statements. Plans must be construction / permit ready. 3. Provide type of back flow preventer to be used (PVB, AVB, DC, RP etc.) and applicable design standard Florida Building Code-Plumbing Section 608.1, Table 608.1. 4. Add testing requirements for back flow preventer. Back flow preventer to be tested at time of installation by a Florida licensed, 3rd party, back flow prevention testing agency. Back flow preventer shall be provided with "approved" inspection tag issued by testing and inspection company at time of final inspection by the City of Palm Coast. Florida Building Code-Plumbing Section 312.10.2.
PLLA CANCEL
PLUM CANCEL