I want to search for...
Permit #2024071553
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00700-0060 |
| CONDITIONED SPACE: 2628 sqft |
| OPENED PORCH (WITH ROOF) : 290 sqft |
| GARAGE: 1004 sqft |
| Total Square Footage: 3922 sqft |
| Block: 00700 |
| Subdivision: 7058 - |
| Job Phone: 386-931-5741 |
| Location Address: 12 SECRETARY TRL |
| Type: DU - DUPLEX |
| Issue Date: 08/28/2024 |
| NOC: RECORDED |
| Applicant name: MICHAEL MARINO HANSEN |
| Owner: JM PROPERTIES X LLC |
|
Address PO BOX 1347 FLAGLER BEACH, FL 32136 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
RBI HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 1347 PALM COAST, FL 32137 |
RB29003877 (Exp: 08/31/2027) | 386-585-4097 |
Sub Contractors
ARTHUR J PASCOE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 730007 ORMOND BEACH, FL 32174 |
EC13007168 (Exp: 08/31/2026) | 386-547-6439 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 912 PALM COAST, FL 32164 |
CAC1820539 (Exp: 08/31/2026) | 386-264-0550 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
MICHAEL JON HOWES
| Status | Location Address | State License Number | Phone |
| CANCEL |
29 MALACOMPRA RD PALM COAST, FL 32137 |
RC29027794 (Exp: 08/31/2025) | 410-984-6787 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/06/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: 6/4/2025 - PREVIOUS INSPECTION NOTES 6-4-25 1. Both A/C condensating drains need to be 6" above the ground. 2. Energy cals do not match. 3. Light in garage of 12B do not work. | |||
| ROW - FINAL APRON (AFTER POUR) | 06/05/2025 | APPROVED | FSLADISH |
| Note: 6/5/25 REQUIRED SWALE CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 6/4/2025 - PREVIOUS INSPECTION NOTES 6/4/25 RECEIVED CALL FROM JIM CM TO PLEASE CANCEL THIS INSPECTION. Inspector Notes from Inspection 9465 6/3/25 I AM APPROVING THIS FIELD SURVEY AS NOTED THAT YOU WILL BE REQUIRED TO FIX THE FRONT SWALE ON THE LEFT SIDE WHERE YOU WENT IN AND OUT WITH A MACHINE. REMOVE/REPAIR THE AREA OUTLINED IN PINK PAINT AND COMPACT IT AND GRADE IT TO HAVE POSITIVE DRAINAGE FLOW IN AS GOOD OR BETTER CONDITION THAN WHEN YOU BEGAN CONSTRUCTION. YOU WILL ALSO NEED TO SOD THE BARE AREA YOU HAVE LAID STRAW. THE SOD SHOULD BE LAID TO 4" FROM THE FENCE. APPROVING AS NOTED AS A COURTESY SO YOU WILL BE ABLE TO MOVE FORWARD WITH INSPECTIONS. CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE. | |||
| ROW - FINAL INSPECTION | 06/05/2025 | APPROVED | FSLADISH |
| Note: 6/5/25 REQUIRED SWALE CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 6/4/2025 - PREVIOUS INSPECTION NOTES 6/4/25 RECEIVED CALL FROM JIM CM TO PLEASE CANCEL THIS INSPECTION. Inspector Notes from Inspection 9465 6/3/25 I AM APPROVING THIS FIELD SURVEY AS NOTED THAT YOU WILL BE REQUIRED TO FIX THE FRONT SWALE ON THE LEFT SIDE WHERE YOU WENT IN AND OUT WITH A MACHINE. REMOVE/REPAIR THE AREA OUTLINED IN PINK PAINT AND COMPACT IT AND GRADE IT TO HAVE POSITIVE DRAINAGE FLOW IN AS GOOD OR BETTER CONDITION THAN WHEN YOU BEGAN CONSTRUCTION. YOU WILL ALSO NEED TO SOD THE BARE AREA YOU HAVE LAID STRAW. THE SOD SHOULD BE LAID TO 4" FROM THE FENCE. APPROVING AS NOTED AS A COURTESY SO YOU WILL BE ABLE TO MOVE FORWARD WITH INSPECTIONS. CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE. | |||
| U -UTILITY RESIDENTIAL FINAL | 06/04/2025 | FINAL APPROVED | BWRIGHT |
| ROW - FINAL APRON (AFTER POUR) | 06/04/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 6/4/25 RECEIVED CALL FROM JIM CM TO PLEASE CANCEL THIS INSPECTION. Inspector Notes from Inspection 9465 6/3/25 I AM APPROVING THIS FIELD SURVEY AS NOTED THAT YOU WILL BE REQUIRED TO FIX THE FRONT SWALE ON THE LEFT SIDE WHERE YOU WENT IN AND OUT WITH A MACHINE. REMOVE/REPAIR THE AREA OUTLINED IN PINK PAINT AND COMPACT IT AND GRADE IT TO HAVE POSITIVE DRAINAGE FLOW IN AS GOOD OR BETTER CONDITION THAN WHEN YOU BEGAN CONSTRUCTION. YOU WILL ALSO NEED TO SOD THE BARE AREA YOU HAVE LAID STRAW. THE SOD SHOULD BE LAID TO 4" FROM THE FENCE. APPROVING AS NOTED AS A COURTESY SO YOU WILL BE ABLE TO MOVE FORWARD WITH INSPECTIONS. CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE. | |||
| U-CROSS CONNECTION | 06/04/2025 | APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 06/04/2025 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 6-4-25 1. Both A/C condensating drains need to be 6" above the ground. 2. Energy cals do not match. 3. Light in garage of 12B do not work. | |||
| ROW - FINAL INSPECTION | 06/04/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 6/4/25 RECEIVED CALL FROM JIM CM TO PLEASE CANCEL THIS INSPECTION. Inspector Notes from Inspection 9465 6/3/25 I AM APPROVING THIS FIELD SURVEY AS NOTED THAT YOU WILL BE REQUIRED TO FIX THE FRONT SWALE ON THE LEFT SIDE WHERE YOU WENT IN AND OUT WITH A MACHINE. REMOVE/REPAIR THE AREA OUTLINED IN PINK PAINT AND COMPACT IT AND GRADE IT TO HAVE POSITIVE DRAINAGE FLOW IN AS GOOD OR BETTER CONDITION THAN WHEN YOU BEGAN CONSTRUCTION. YOU WILL ALSO NEED TO SOD THE BARE AREA YOU HAVE LAID STRAW. THE SOD SHOULD BE LAID TO 4" FROM THE FENCE. APPROVING AS NOTED AS A COURTESY SO YOU WILL BE ABLE TO MOVE FORWARD WITH INSPECTIONS. CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/03/2025 | APPROVED | FSLADISH |
| Note: 6/3/25 ELEVATION SHOTS INDICATE DRAINAGE NOW MEETS COPC MINIMUM STANDARDS WITH THIS SURVEY. _____________________________________________________________________________________________________________________ 5/22/2025 - PREVIOUS INSPECTION NOTES 5.22/25 You are still not showing 6" of fall in the first 10ft off of structure. Both of your 10 ft off the structure corner shots indicate you will not have positive flow to the front swale. Please see photo for reference. ______________________________________________________________________________________________________________________ 5/13/2025 - PREVIOUS INSPECTION NOTES 5/13/25 YOU DO NOT HAVE THE REQUIRED 6" FALL IN THE FIRST 10' OFF THE REAR OF THE STRUCTURE.1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT. SEE PHOTO FOR REFERENCE | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/03/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/3/25 I AM APPROVING THIS FIELD SURVEY AS NOTED THAT YOU WILL BE REQUIRED TO FIX THE FRONT SWALE ON THE LEFT SIDE WHERE YOU WENT IN AND OUT WITH A MACHINE. REMOVE/REPAIR THE AREA OUTLINED IN PINK PAINT AND COMPACT IT AND GRADE IT TO HAVE POSITIVE DRAINAGE FLOW IN AS GOOD OR BETTER CONDITION THAN WHEN YOU BEGAN CONSTRUCTION. YOU WILL ALSO NEED TO SOD THE BARE AREA YOU HAVE LAID STRAW. THE SOD SHOULD BE LAID TO 4" FROM THE FENCE. APPROVING AS NOTED AS A COURTESY SO YOU WILL BE ABLE TO MOVE FORWARD WITH INSPECTIONS. CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE. PHOTO FOR REFERENCE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/22/2025 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 5.22/25 You are still not showing 6" of fall in the first 10ft off of structure. Both of your 10 ft off the structure corner shots indicate you will not have positive flow to the front swale. Please see photo for reference. ______________________________________________________________________________________________________________________ 5/13/2025 - PREVIOUS INSPECTION NOTES 5/13/25 YOU DO NOT HAVE THE REQUIRED 6" FALL IN THE FIRST 10' OFF THE REAR OF THE STRUCTURE.1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT. SEE PHOTO FOR REFERENCE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/13/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 5/13/25 YOU DO NOT HAVE THE REQUIRED 6" FALL IN THE FIRST 10' OFF THE REAR OF THE STRUCTURE.1 Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT. SEE PHOTO FOR REFERENCE | |||
| ROW- PRE-APRON (PRE-POUR) | 04/25/2025 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| GRAVITY SEWER TEST | 04/21/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 SEC-24-162-C SWALE BLOCKED BY PORTABLE RESTROOM, WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 04/21/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 SEC-24-162-C SWALE BLOCKED BY PORTABLE RESTROOM, WATER SERVICE NOT RAN YET THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC - EARLY POWER | 04/15/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 4-15-25 1. Emailed FPL at 1:48. | |||
| FIREWALL FINAL | 02/18/2025 | APPROVED | MCONTRYMAN |
| LATH/BRICK/ WATER BARRIER | 02/14/2025 | APPROVED | BTAYLOR |
| INSULATION | 02/11/2025 | APPROVED | BTAYLOR |
| ALL ROUGH | 02/07/2025 | APPROVED | BTAYLOR |
| Note: 2/6/2025 - PREVIOUS INSPECTION NOTES 2-6-25 1. Electrical panel in A unit needs holes in top filled. 2. Double washer dryer in both units? 3. Master bath exhaust fan in A unit has fallen out of the roof. | |||
| FIREWALL FRAMING | 02/06/2025 | APPROVED | BTAYLOR |
| ALL ROUGH | 02/06/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 2-6-25 1. Electrical panel in A unit needs holes in top filled. 2. Double washer dryer in both units? 3. Master bath exhaust fan in A unit has fallen out of the roof. | |||
| FIREWALL DRYWALL NAILING | 11/14/2024 | APPROVED | BTAYLOR |
| Note: 11/13/2024 - PREVIOUS INSPECTION NOTES 11/12/2024 - PREVIOUS INSPECTION NOTES 11-12-24 1. Screws have been covered up. 11-13-24 1. Can not see screws on top and bottom edges. | |||
| ROOF VALLEY & METAL | 11/14/2024 | APPROVED | BTAYLOR |
| FIREWALL DRYWALL NAILING | 11/13/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 11/12/2024 - PREVIOUS INSPECTION NOTES 11-12-24 1. Screws have been covered up. 11-13-24 1. Can not see screws on top and bottom edges. | |||
| FIREWALL DRYWALL NAILING | 11/12/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 11-12-24 1. Screws have been covered up. | |||
| WALL SHEATHING | 11/06/2024 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/06/2024 | APPROVED | BTAYLOR |
| FOUND SURVEY APPROVED (OFFICE) | 10/29/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 10/18/2024 | APPROVED | BTAYLOR |
| MONOLITHIC SLAB | 10/03/2024 | APPROVED | BTAYLOR |
| Note: 10/2/2024 - PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 10/02/2024 | CANCELLED BY APPLICANT | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/01/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: SEC-24-162-C SWALE BLOCKED BY PORTABLE RESTROOM, WATER SERVICE NOT RAN YET | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 09/30/2024 | APPROVED | CPISCITELLI |
| WATER METER INSTALLATION REQUEST | 09/11/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| CUSVC | COMPLETE | 05/22/2025 | 05/28/2025 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/22/2025 | 05/22/2025 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/06/2025 | 05/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/29/2024 | 10/29/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/29/2024 | 10/29/2024 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/24/2024 | 09/30/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/20/2024 | 08/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/12/2024 | 08/12/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2024 | 08/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Soffits are 16 inches wide. Provide soffit construction detail in accordance with Section R704.2.1 through R704.2.4. | |||
| ELEC | COMPLETE | 08/06/2024 | 08/12/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/06/2024 | 08/12/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Soffits are 16 inches wide. Provide soffit construction detail in accordance with Section R704.2.1 through R704.2.4. | |||
| ZON | HOLD | 08/06/2024 | 08/06/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Must have a minimum of 16 foundation plantings with 8 along the front and four along each side. Screening for AC's do not count toward the 16 required | |||
| BADMIN | COMPLETE | 07/31/2024 | 08/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/31/2024 | 08/05/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM All comments per FBC Residential 2023 8th Edition 1. Udate code year on all pages in engineering note box to 2023 8th edition. 107.2.1 2. Plan Page 6.0 under roof general notes update code year 107.2.1 3. Plan Page 9.0 details 3 and 4 have wording that has been over written and not readable. 107.21. 4. Provide presumptive load bearing value used for foundation design per R401.4.1 5.Provide soffit dimensions and framing detail per R704.2.1 6. Update florida product approval revision number for underlayment to 2023 code cycle | |||
| CUSVC | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/31/2024 | 08/01/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer need to be GFCI protected. NEC 2020 210.8 | |||
| ENGIN1 | COMPLETE | 07/31/2024 | 07/31/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 07/31/2024 | 08/02/2024 |
| LOCATE | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/31/2024 | 07/31/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/31/2024 | 08/05/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Body color does not meet the LRV for a pastel must be 80 or greater Must have a minimum of 16 foundation plantings with 8 along the front and four along each side. Screening for AC's do not count toward the 16 required | |||
| SWALE | COMPLETE | 07/31/2024 | 11/06/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/06/2025 |
| WATER-METER | ¤965.03 | 05/28/2025 |
| WATER-METER | ¤965.03 | 05/28/2025 |
| WATER- TURN ON | ¤50.00 | 05/28/2025 |
| WATER- TURN ON | ¤50.00 | 05/28/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 05/28/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 05/28/2025 |
| SITE PLAN 30 | ¤30.00 | 08/28/2024 |
| WATER- TURN ON | ¤50.00 | 08/28/2024 |
| ADJUSTMENT 10% | (¤186.21) | 08/28/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/28/2024 |
| INSPECTION - RESIDENTIAL | ¤1,427.25 | 08/28/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤404.82 | 08/28/2024 |
| CONNECTION FEES | ¤2,374.52 | 08/28/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 08/28/2024 |
| IMPACT FEE FIRE | ¤856.18 | 08/28/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 08/28/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 08/28/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 08/28/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 08/28/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 08/28/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 08/28/2024 |
| SURCHARGE FS 533.721 | ¤16.76 | 08/28/2024 |
| SURCHARGE - FS 468.631 | ¤25.14 | 08/28/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/28/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/28/2024 |
| SW ENG PRE APRON | ¤30.00 | 08/28/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/28/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/28/2024 |
| SEWER CREDIT | (¤1,420.00) | 08/28/2024 |
| SEWER INSPECTION | ¤25.00 | 08/28/2024 |
| SEWER CAPITAL FACILITY | ¤12,241.04 | 08/28/2024 |
| WATER CAPITAL FACILITY FEE | ¤8,702.28 | 08/28/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤45,613.02 |