Permit #2024071579
Permit Details
Status: COED
| Parcel Id: 06-12-31-5180-00000-0790 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 424 sqft |
| OPENED PORCH (WITH ROOF) : 213 sqft |
| Total Square Footage: 2689 sqft |
| Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1 |
| Job Phone: 904-669-7000 |
| Location Address: 28 MULBERRY RD |
| Type: TH - TOWNHOUSE |
| Issue Date: 08/09/2024 |
| NOC: RECORDED |
| Applicant name: PAUL GILBERT AXTELL |
| Owner: TOLL SOUTHEAST LP COMPANY INC |
|
Address 1140 VIRGINIA DRIVE FORT WASHINGTON, PA 19034 |
| Lot: 79 |
| Contracted Stated Job Value: ¤380,844.00 |
| Job Description: TOWNHOME |
| Type: CN |
Contractor
TOLL BROS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
40 EVEREST LN, STE 5 ST JOHNS, FL 32259 |
CGC60445 (Exp: 08/31/2026) | 904-217-3852 |
Sub Contractors
JAMES F QUINN III
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3210 SW 40TH BLVD STE F GAINESVILLE, FL 32608 |
EC13010994 (Exp: 08/31/2026) | 352-378-9274 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
HARLEY M BRYAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5223 EDGEWOOD CT ORMOND BEACH, FL 32174 |
LI26657 (Exp: 08/31/2028) | 386-463-2700 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/13/2025 | FINAL APPROVED | BTAYLOR |
| Note: 2/11/2025 - PREVIOUS INSPECTION NOTES 2/11/25 1. Upper bath shower has no hot water 2. No double oven installed. Could not verify electrical connections Make ALL repairs before calling in for re-inspection 2/5/2025 - PREVIOUS INSPECTION NOTES 2/5/25 1. Master bath shower has luke warm water 2. Master bath right side sink does not hold water 3. Upper bath sink has leak 4. Upper bath shower has no hot water 5. Low voltage box on ceiling in lenai needs cover 6. No double oven installed. Could not verify electrical connections | |||
| BLD - BUILDING FINAL | 02/11/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 2/11/25 1. Upper bath shower has no hot water 2. No double oven installed. Could not verify electrical connections Make ALL repairs before calling in for re-inspection 2/5/2025 - PREVIOUS INSPECTION NOTES 2/5/25 1. Master bath shower has luke warm water 2. Master bath right side sink does not hold water 3. Upper bath sink has leak 4. Upper bath shower has no hot water 5. Low voltage box on ceiling in lenai needs cover 6. No double oven installed. Could not verify electrical connections | |||
| BLD - BUILDING FINAL | 02/05/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: *** NOTES ADDED BY MCONTRYMAN 2/5/2025 3:01:18 PM *** For item 6, if double oven/appliance is not installed, a required breaker lock must be installed at time of next inspection 2/5/25 1. Master bath shower has luke warm water 2. Master bath right side sink does not hold water 3. Upper bath sink has leak 4. Upper bath shower has no hot water 5. Low voltage box on ceiling in lenai needs cover 6. No double oven installed. Could not verify electrical connections | |||
| ELECTRIC - EARLY POWER | 01/27/2025 | APPROVED - AS NOTED | BTAYLOR |
| Note: 1-27-25 1. Emailed FPL at 12:08. Inspector Notes from Inspection 2200 | |||
| U-CROSS CONNECTION | 01/14/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 1/14/2025 3:52:02 PM *** reclaim irrigation-no cros connection | |||
| U -UTILITY RESIDENTIAL FINAL | 01/14/2025 | FINAL APPROVED | LFITZGERALD |
| LDSC- LANDSCAPE FINAL | 01/09/2025 | APPROVED | RPICATAGI |
| FIREWALL DRYWALL NAILING | 10/28/2024 | APPROVED | PKNAPIK |
| GRAVITY SEWER TEST | 10/25/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 10/25/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 10/22/2024 | APPROVED | PKNAPIK |
| Note: 10/18/2024 - PREVIOUS INSPECTION NOTES 10/18/2024 1. Missing fireblocking above electrical panel in garage. FBC R302.11 2. Seal opening above electrical panel at ceiling. Inspector Notes from Inspection 2441 10/15/2024 Check at insulation. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/2024 1. Seal penetrations in firewall on the saircase. | |||
| INSULATION | 10/18/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 10/18/2024 1. Missing fireblocking above electrical panel in garage. FBC R302.11 2. Seal opening above electrical panel at ceiling. Inspector Notes from Inspection 2441 10/15/2024 Check at insulation. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/2024 1. Seal penetrations in firewall on the saircase. | |||
| LATH/BRICK/ WATER BARRIER | 10/15/2024 | APPROVED | PKNAPIK |
| ALL ROUGH | 10/15/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 10/15/2024 1. 2 Point Connection for bath fans. FBC M1601.4.1 2. 5 Ft Head test. FBCR P2503.7 3. Missing nail plates in laundry. FBCR P2603.2.1 4. Center outlet on kitchen island needs to be an a separate cuircuit. Cannot be on a small appliance circuit that is on the island. NEC 210.52 (B) (2) NEC 210.52 (C) (3) (3) | |||
| ALL ROUGH | 10/15/2024 | APPROVED - AS NOTED | PKNAPIK |
| Note: 10/15/2024 Check notes below at insulation. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/2024 1. 2 Point Connection for bath fans. FBC M1601.4.1 2. 5 Ft Head test. FBCR P2503.7 3. Missing nail plates in laundry. FBCR P2603.2.1 4. Center outlet on kitchen island needs to be an a separate cuircuit. Cannot be on a small appliance circuit that is on the island. NEC 210.52 (B) (2) NEC 210.52 (C) (3) (3) | |||
| FIREWALL FRAMING | 10/15/2024 | APPROVED | PKNAPIK |
| FIREWALL PENETRATIONS | 10/15/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 10/15/2024 1. Seal penetrations in firewall on the saircase. | |||
| FIREWALL PENETRATIONS | 10/15/2024 | APPROVED - AS NOTED | PKNAPIK |
| Note: 10/15/2024 Check at insulation. 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/2024 1. Seal penetrations in firewall on the saircase. | |||
| ELECTRIC-TUG | 10/02/2024 | APPROVED - AS NOTED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/25/2024 | APPROVED | KSANDOE |
| WATER METER INSTALLATION REQUEST | 09/25/2024 | APPROVED | CBOWERMASTER |
| ROOF VALLEY & METAL | 09/19/2024 | APPROVED | KSANDOE |
| WALL SHEATHING | 09/19/2024 | APPROVED | KSANDOE |
| FOUNDATION SURVEY - OFFICE USE ONLY | 08/30/2024 | APPROVED | DLEAP |
| MONOLITHIC SLAB | 08/19/2024 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/16/2024 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| ARCHR | COMPLETE | 10/22/2024 | 10/29/2024 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 08/29/2024 | 08/30/2024 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/29/2024 | 08/29/2024 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ARCHR | COMPLETE | 07/31/2024 | 08/05/2024 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 07/31/2024 | 08/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/31/2024 | 08/05/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 07/31/2024 | 08/08/2024 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/31/2024 | 08/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | CANCEL | 07/31/2024 | 08/01/2024 |
| GAS | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 07/31/2024 | 08/05/2024 |
| Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 07/31/2024 | 08/02/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/06/2025 |
| CONNECTION FEES | ¤25.00 | 08/14/2024 |
| WATER-METER | ¤514.49 | 08/14/2024 |
| WATER-METER | ¤427.42 | 08/14/2024 |
| SEWER INSPECTION | ¤25.00 | 08/14/2024 |
| SITE PLAN 30 | ¤30.00 | 08/09/2024 |
| ADJUSTMENT 10% | (¤134.49) | 08/09/2024 |
| ADMINISTRATIVE - MASTER FILE | ¤325.00 | 08/09/2024 |
| INSPECTION - RESIDENTIAL | ¤1,047.75 | 08/09/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤297.18 | 08/09/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 08/09/2024 |
| IMPACT FEE FIRE | ¤428.09 | 08/09/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/09/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/09/2024 |
| IMPACT FEE PARKS | ¤1,800.99 | 08/09/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/09/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,638.00 | 08/09/2024 |
| SURCHARGE FS 533.721 | ¤12.10 | 08/09/2024 |
| SURCHARGE - FS 468.631 | ¤18.16 | 08/09/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,492.69 |