Permit #2024080027
Permit Details
Status: COED
| Parcel Id: 19-12-31-2675-00000-00I0 |
| Total Square Footage: 1290 sqft |
| Subdivision: 2320 - FLAGLER VILLAGE |
| Job Phone: 407-703-2972 |
| Location Address: 1 SANDY LN |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 11/21/2024 |
| NOC: RECORDED |
| Applicant name: MICHAEL TUCKER HOLMES |
| Owner: MERITAGE HOMES OF FLORIDA INC |
|
Address 8800 EAST RAINTREE DRIVE #300 SCOTTSDALE , AZ 85260 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Amenity Center |
| Type: CN |
Contractor
JK2 CONSTRUCTION
| Status | Location Address | State License Number | Phone |
| ACTIVE |
530 HOLTS LAKE CT SUITE 304 APOPKA, FL 32703 |
CGC1522330 (Exp: 08/31/2026) | 407-703-2972 |
Sub Contractors
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
DONALD JOSEPH COHEN
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2771 SUMMERFIELD ST DELTONA, FL 32738 |
EC13006904 (Exp: 08/31/2026) | 386-473-6225 |
MICHAEL ANDREW JENKINS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19221 BAKER RD UMATILLA , FL 32784 |
CAC1818592 (Exp: 08/31/2026) | 321-217-6254 |
Inspection History
| Type | Request Date | Result | Inspector |
| WATER SERVICE | 06/26/2025 | APPROVED | MGIBSON |
| Note: 4/2/2025 - PREVIOUS INSPECTION NOTES NOT TIED IN YET | |||
| U - UTILITY COMMERCIAL FINAL | 06/26/2025 | FINAL APPROVED | LFITZGERALD |
| Note: 5/30/2025 - PREVIOUS INSPECTION NOTES Site work still needs to be complete. | |||
| U - UTILITY COMMERCIAL FINAL | 05/30/2025 | Disapproved - NO FEE | BWRIGHT |
| Note: Site work still needs to be complete. | |||
| BUILDING FINAL | 05/30/2025 | APPROVED | PBUCKLEY |
| FIRE FINAL | 05/30/2025 | APPROVED | JMUNSON |
| ELECTRIC FINAL | 05/16/2025 | APPROVED | RMARTIN |
| Note: 5/14/2025 - PREVIOUS INSPECTION NOTES 5/15/25 Still need to do, not correct connectors. seal tight connections at well/Irrigation needs to be fixed, needs proper connections NEC 350 5/6/2025 - PREVIOUS INSPECTION NOTES 5/6/25 seal tight connections at well/Irrigation needs to be fixed, needs proper connections NEC 350 4/22/2025 - PREVIOUS INSPECTION NOTES 1. Elec sub still working FBC (A)107.4 2. Panel schdule does not match plans, revision required FBC (A)107.4 3. Early power inspection was not approved yet 4. Site lighting power has not been pulled yet Call back in once ready for full re-inspection | |||
| ELECTRIC FINAL | 05/14/2025 | Disapproved - NO FEE | RMARTIN |
| Note: 5/15/25 Still need to do, not correct connectors. seal tight connections at well/Irrigation needs to be fixed, needs proper connections NEC 350 5/6/2025 - PREVIOUS INSPECTION NOTES 5/6/25 seal tight connections at well/Irrigation needs to be fixed, needs proper connections NEC 350 4/22/2025 - PREVIOUS INSPECTION NOTES 1. Elec sub still working FBC (A)107.4 2. Panel schdule does not match plans, revision required FBC (A)107.4 3. Early power inspection was not approved yet 4. Site lighting power has not been pulled yet Call back in once ready for full re-inspection | |||
| ELECTRIC FINAL | 05/06/2025 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: 5/6/25 seal tight connections at well/Irrigation needs to be fixed, needs proper connections NEC 350 4/22/2025 - PREVIOUS INSPECTION NOTES 1. Elec sub still working FBC (A)107.4 2. Panel schdule does not match plans, revision required FBC (A)107.4 3. Early power inspection was not approved yet 4. Site lighting power has not been pulled yet Call back in once ready for full re-inspection | |||
| PLUMBING FINAL | 04/29/2025 | APPROVED | MGIBSON |
| Note: 4/22/2025 - PREVIOUS INSPECTION NOTES NEED HOT WATER BREAKER ON FOR PLUMBING FINAL, LOWER DRINKING FOUNTAIN NEEDS AJUSTED , MISSING TRIM RING ON MENS URNIAL | |||
| HVAC FINAL | 04/23/2025 | FINAL APPROVED | CPISCITELLI |
| ELECTRIC - EARLY POWER | 04/23/2025 | APPROVED | RMARTIN |
| Note: 3/13/2025 - PREVIOUS INSPECTION NOTES TUG inspection was needed, Power release to meter/panel only. Call back in when all elec. is safed off for early power. Emailed FPL @ 9:15am | |||
| ELECTRIC FINAL | 04/22/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Elec sub still working FBC (A)107.4 2. Panel schdule does not match plans, revision required FBC (A)107.4 3. Early power inspection was not approved yet 4. Site lighting power has not been pulled yet Call back in once ready for full re-inspection | |||
| PLUMBING FINAL | 04/22/2025 | Disapproved - NO FEE | MGIBSON |
| Note: NEED HOT WATER BREAKER ON FOR PLUMBING FINAL, LOWER DRINKING FOUNTAIN NEEDS AJUSTED , MISSING TRIM RING ON MENS URNIAL | |||
| EXTERIOR ARCHITECTURAL FEATURES | 04/22/2025 | APPROVED | FWILLIS |
| GRAVITY SEWER | 04/03/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 3100 SEWER TIE IN IS APPROVED , C/M TO SCHEDUAL GRAVITY SEWER FOR 4/3/25 | |||
| BLD - SEWER TIE IN | 04/02/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: SEWER TIE IN IS APPROVED , C/M TO SCHEDUAL GRAVITY SEWER FOR 4/3/25 | |||
| WATER SERVICE | 04/02/2025 | Disapproved - NO FEE | MGIBSON |
| Note: NOT TIED IN YET | |||
| ELECTRIC - EARLY POWER | 03/13/2025 | PARTIALLY APPROVED | MKRASKI |
| Note: TUG inspection was needed, Power release to meter/panel only. Call back in when all elec. is safed off for early power. Emailed FPL @ 9:15am | |||
| ELECTRIC 2ND ROUGH | 02/24/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 2/24/2025 2:48:02 PM *** This inspection was already done Inspector Notes from Inspection 3190 *** NOTES ADDED BY RMARTIN 2/21/2025 9:01:02 AM *** This was already approved, added 1st rough for feeder conduit and pool equipment, NEED TO REMEMBER TO CALL IN SITE LIGHTING INSPECTIONS THAT ARE ON YOUR SITE PERMIT WHEN READY Inspector Notes from Inspection 3190 2nd rough approved call first rough in once service conduit is installed | |||
| PLUMBING 2ND ROUGH | 02/24/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 3080 2/12/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3070 12/9/2024 - PREVIOUS INSPECTION NOTES NOT READY PLANS NOT MATCH PER WHAT IS IN FIELD. WATER DISTRIBUTION LINES WERE REMOVEDAND WILL BE RAN OVER HEAD PER PLAN WITH RECIRCULATION PUMP MEET WITH PLUMBER ON SITE, WENT OVER WHAT NEEDS TO BE CORRECTED, VENT IN MENS BATHROOM NEDEDS TO BE CHANGED AT 1 1/2'' TEE TO A TWIN ELL, ALL INSULATION IN TOP PLATES NEED TO BE REMOVED AND FIRE RATED FOAM INSTALLED, FLUSH VALVE IN WOMENS ''ADA'' NEEDS TO BE TO THE OPEN SIDE. NAIL PLATES NEED TO BE 2 1/2'' FROM TOP PLATE DOWN. CHECK AT NEXT INSPECTION. HAVE SHOCK ARRESTORS INSTALLED BY ABOVE CEILING INSPECTION ON ALL FLUSH VALVES | |||
| ELECTRIC 1ST ROUGH | 02/21/2025 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC 2ND ROUGH | 02/21/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 2/21/2025 9:01:02 AM *** This was already approved, added 1st rough for feeder conduit and pool equipment, NEED TO REMEMBER TO CALL IN SITE LIGHTING INSPECTIONS THAT ARE ON YOUR SITE PERMIT WHEN READY Inspector Notes from Inspection 3190 2nd rough approved call first rough in once service conduit is installed | |||
| ELECTRIC 1ST ROUGH | 02/21/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 2/21/2025 8:58:12 AM *** Looked at service conduit to fpl pole and conduit to pool equipment Inspector Notes from Inspection 3190 2nd rough approved call first rough in once service conduit is installed 2/20/2025 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC 2ND ROUGH | 02/20/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 2nd rough approved call first rough in once service conduit is installed | |||
| ELECTRIC 1ST ROUGH | 02/20/2025 | CANCELLED BY APPLICANT | MKRASKI |
| PLUMBING 2ND ROUGH | 02/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: 2/12/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3070 12/9/2024 - PREVIOUS INSPECTION NOTES NOT READY PLANS NOT MATCH PER WHAT IS IN FIELD. WATER DISTRIBUTION LINES WERE REMOVEDAND WILL BE RAN OVER HEAD PER PLAN WITH RECIRCULATION PUMP MEET WITH PLUMBER ON SITE, WENT OVER WHAT NEEDS TO BE CORRECTED, VENT IN MENS BATHROOM NEDEDS TO BE CHANGED AT 1 1/2'' TEE TO A TWIN ELL, ALL INSULATION IN TOP PLATES NEED TO BE REMOVED AND FIRE RATED FOAM INSTALLED, FLUSH VALVE IN WOMENS ''ADA'' NEEDS TO BE TO THE OPEN SIDE. NAIL PLATES NEED TO BE 2 1/2'' FROM TOP PLATE DOWN. CHECK AT NEXT INSPECTION. HAVE SHOCK ARRESTORS INSTALLED BY ABOVE CEILING INSPECTION ON ALL FLUSH VALVES | |||
| ELECTRIC 1ST ROUGH | 02/18/2025 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 2ND ROUGH | 02/12/2025 | PARTIALLY APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 3070 12/9/2024 - PREVIOUS INSPECTION NOTES NOT READY PLANS NOT MATCH PER WHAT IS IN FIELD. WATER DISTRIBUTION LINES WERE REMOVEDAND WILL BE RAN OVER HEAD PER PLAN WITH RECIRCULATION PUMP MEET WITH PLUMBER ON SITE, WENT OVER WHAT NEEDS TO BE CORRECTED, VENT IN MENS BATHROOM NEDEDS TO BE CHANGED AT 1 1/2'' TEE TO A TWIN ELL, ALL INSULATION IN TOP PLATES NEED TO BE REMOVED AND FIRE RATED FOAM INSTALLED, FLUSH VALVE IN WOMENS ''ADA'' NEEDS TO BE TO THE OPEN SIDE. NAIL PLATES NEED TO BE 2 1/2'' FROM TOP PLATE DOWN. CHECK AT NEXT INSPECTION | |||
| FRAMING | 02/10/2025 | APPROVED | FWILLIS |
| Note: 2/10/25 - WINDOW INSPECTION Inspector Notes from Inspection 3463 Approved to move forward. 1/29/2025 - PREVIOUS INSPECTION NOTES Roofing worksheet calls for Owens Corning peel and stick underlayment. Does not match what is installed. Product approval numbers on roofing worsheet are also expired. Please submit a revised roofing worksheet | |||
| HVAC ROUGH | 02/05/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/5/2025 3:49:44 PM *** | |||
| ROOF VALLEY & METAL | 02/05/2025 | APPROVED - AS NOTED | KSANDOE |
| Note: Approved to move forward. 1/29/2025 - PREVIOUS INSPECTION NOTES Roofing worksheet calls for Owens Corning peel and stick underlayment. Does not match what is installed. Product approval numbers on roofing worsheet are also expired. Please submit a revised roofing worksheet | |||
| LATH/BRICK/WATER BARRIER | 02/03/2025 | APPROVED | KSANDOE |
| Note: 1/21/2025 - PREVIOUS INSPECTION NOTES Partial Inspection on Tyvek Covering OSB on first floor. Still need upper part of front porch and side gables. | |||
| ROOF VALLEY & METAL | 01/29/2025 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Roofing worksheet calls for Owens Corning peel and stick underlayment. Does not match what is installed. Product approval numbers on roofing worsheet are also expired. Please submit a revised roofing worksheet | |||
| WALL SHEATHING | 01/28/2025 | APPROVED | KSANDOE |
| Note: 1/23/2025 - PREVIOUS INSPECTION NOTES OSB on the rest of the outside is ok. Only thing left is the OSB on the inside of the tower. 1/16/2025 - PREVIOUS INSPECTION NOTES OSB ON FIRST FLOOR ONLY INSPECTED. | |||
| WALL SHEATHING | 01/23/2025 | PARTIALLY APPROVED | HCAMACHO |
| Note: OSB on the rest of the outside is ok. Only thing left is the OSB on the inside of the tower. 1/16/2025 - PREVIOUS INSPECTION NOTES OSB ON FIRST FLOOR ONLY INSPECTED. | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 01/23/2025 | APPROVED | HCAMACHO |
| LATH/BRICK/WATER BARRIER | 01/21/2025 | PARTIALLY APPROVED | HCAMACHO |
| Note: Partial Inspection on Tyvek Covering OSB on first floor. Still need upper part of front porch and side gables. | |||
| WALL SHEATHING | 01/16/2025 | PARTIALLY APPROVED | KSANDOE |
| Note: OSB ON FIRST FLOOR ONLY INSPECTED. | |||
| FOUNDATION SURVEY - OFFICE USE ONLY | 01/02/2025 | APPROVED | DLEAP |
| MONOLITHIC SLAB | 12/20/2024 | APPROVED | FWILLIS |
| Note: 12/17/2024 - PREVIOUS INSPECTION NOTES FOOTER NOT AT PROPER DEPTH AS PER PLAN PAGE S1.0 DETAIL F01 EXTERIOR WALL FTG. SHOULD BE 20" DEEP. BOTH AREAS ARE AT 18" DEEP. CALLED AS REQUESTED, COULDN'T LEAVE A MESSAGE BECAUSE HIS MAILBOX IS FULL. | |||
| FOOTER | 12/20/2024 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 12/17/2024 | Disapproved - NO FEE | FWILLIS |
| Note: FOOTER NOT AT PROPER DEPTH AS PER PLAN PAGE S1.0 DETAIL F01 EXTERIOR WALL FTG. SHOULD BE 20" DEEP. BOTH AREAS ARE AT 18" DEEP. CALLED AS REQUESTED, COULDN'T LEAVE A MESSAGE BECAUSE HIS MAILBOX IS FULL. | |||
| PLUMBING 1ST ROUGH | 12/11/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: 12/9/2024 - PREVIOUS INSPECTION NOTES NOT READY PLANS NOT MATCH PER WHAT IS IN FIELD. WATER DISTRIBUTION LINES WERE REMOVEDAND WILL BE RAN OVER HEAD PER PLAN WITH RECIRCULATION PUMP | |||
| PLUMBING 1ST ROUGH | 12/09/2024 | Disapproved - NO FEE | MGIBSON |
| Note: NOT READY PLANS NOT MATCH PER WHAT IS IN FIELD |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/14/2025 | 02/27/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/30/2025 | 02/11/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Do not upload product approval reports. If adding new numbers submit them on a City of Palm Coast product approval sheet | |||
| BLD | COMPLETE | 01/06/2025 | 01/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 12/30/2024 | 01/02/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/09/2024 | 12/19/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/21/2024 | 11/21/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 11/14/2024 | 11/14/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The subcontractors are to be entered through the onilne permitting portal. we have added the plumbing and roofing contractors for you. The mechanical and electrical contractors are not registered in ourdatabase. When they have registered, you will need to add them through the subcontractor button on the portal. | |||
| ELEC | HOLD | 10/29/2024 | 11/08/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List all Sub contractors | |||
| PLUM | COMPLETE | 10/29/2024 | 11/13/2024 |
| Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/29/2024 | 11/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 09/18/2024 | 09/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 09/18/2024 | 09/24/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List all Sub contractors | |||
| ARCHR | COMPLETE | 09/18/2024 | 10/02/2024 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 09/18/2024 | 09/30/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. 3. REPEAT COMMENT - The City's backflow device referenced in your response comment protects the City's water main and water distribution system from backflow on this site but does not protect the building / site water distribution system from contamination. Per section 454.1.6.3 of the Florida Building Code, Building, every outlet in this building/ site's water system must be protected from backflow by an approved backflow preventer. | |||
| BLD | HOLD | 09/18/2024 | 10/02/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 4. Please mark DEFERRED SUBMITAL for truss drawings/ layout on cover sheet. 6. Please mark DEFERRED SUBMITAL for connector schedule on cover sheet. | |||
| ARCHR | HOLD | 08/01/2024 | 08/15/2024 |
| Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide a schedule of all exterior finishes including paint mfr name, code number and LRV. for all exterior surface. | |||
| BLD | HOLD | 08/01/2024 | 08/15/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. NOA No: 20-0401.10 - Product approval expired. FBC A 107.3 2. Needs details of entry gate per FBC 454.1.3.1.9 3. Show accessibility route from pool to restrooms. Show slopes and cross slopes on both sides of access gate per FBC Accessibility 403.3 4. Truss shop drawings stamped reviewed by EOR per general notes on plans. FBC A 107.3 5. Specify grade and species of wood to be used for framing. FBC A 107.3 6. Provide a connector schedule. FBC 1603 7. Provide water heater specifications FBC A 107.3 | |||
| DSD | COMPLETE | 08/01/2024 | 08/08/2024 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 08/01/2024 | 08/12/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List all Sub contractors 2. Need to reference the 2020 NEC not the 2023 3. Show location of Pool panel 4. Outlets located outside must be weather resistant even when a cover is installed. NEC 2020 406.4 406.9. Remove or revise note on electrical plan. | |||
| FI1 | HOLD | 08/01/2024 | 08/12/2024 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Please upload the Life Safety Plan sheet A1.0 (Indicated on cover sheet A0.1 but was not included in the submittal). FBC 107.3 2. Please show the Fire extinguisher location on the life safety plan. 3. Please show the location of the Emergency on the life safety plan. 107.3 3. Please include the Lightweight roof truss sign per FLORIDA ADMINISTRATIVE CODE 69A-3.012 AND FLORIDA STATUTES 633.027 and place the foloowing information on the Life Safety Plan: PLEASE CALL FIRE MARSHAL, RANDY HOLMES, AT: 386-986-2303 FOR PROPER PLACEMENT AND VERIFICATION OF PROPER DESIGN AND NOTIFICATION FOR THE FIRE FIGHTERS SAFETY BUILDING MARKING SYSTEM PRIOR TO THE PLACEMENT | |||
| GAS | CANCEL | 08/01/2024 | 08/12/2024 |
| MECH | COMPLETE | 08/01/2024 | 08/13/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 08/01/2024 | 08/15/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Provide pool bather count and pool deck load to calculate fixtures per FBCP 403.6.1 2. Provide water distribution piping specifications and appliable design standard(s). FBCP 605 3. Provide backflow protection at potable water supply. Include manufacturer, model # and testing criteria. FBCP 608.1 4. Indicate hose-bibbs are provided with vacuum breakers. FBCP 608 5. Provide drain, waste and vent system piping specification and applicable design standard(s). FBCP 702. 6. Show hose bibbs within 25 ft of restrooms per FBC 454.1.6.1.4 | |||
| UD1 | COMPLETE | 08/01/2024 | 08/12/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 07/08/2025 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 07/08/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 11/21/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 11/21/2024 |
| IMPACT FEE FIRE | ¤866.60 | 11/21/2024 |
| IMPACT FEE FIRE | ¤854.22 | 11/21/2024 |
| SURCHARGE FS 533.721 | ¤20.14 | 11/21/2024 |
| SURCHARGE - FS 468.631 | ¤30.21 | 11/21/2024 |
| SITE PLAN 30 | ¤30.00 | 11/21/2024 |
| ADJUSTMENT 10% | (¤223.75) | 11/21/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 11/21/2024 |
| INSPECTION COMMERCIAL | ¤1,750.00 | 11/21/2024 |
| INSPECTION - FIRE COMMERCIAL | ¤62.50 | 11/21/2024 |
| PLAN REVIEW - COMMERCIAL | ¤350.00 | 11/21/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤3,974.92 |