I want to search for...
Permit #2024080468
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01030-0350 |
| OPENED PORCH (WITH ROOF) : 316 sqft |
| CONDITIONED SPACE: 2622 sqft |
| GARAGE: 998 sqft |
| SCREEN PORCH (SOLID ROOF) : 116 sqft |
| Total Square Footage: 4052 sqft |
| Block: 01030 |
| Subdivision: - |
| Job Phone: 386-585-2654 |
| Location Address: 2 LOUISBURG LN |
| Type: DU - DUPLEX |
| Issue Date: 09/17/2024 |
| NOC: RECORDED |
| Applicant name: DESIDERIO CARLOS CARREIRO |
| Owner: SOARES CARLOS |
|
Address 2 LINDSAY DR B PALM COAST, FL 31237 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
RED LINE CONSTRUCTION CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Sub Contractors
FERNANDO M FARIA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
23 FREELAND LANE PALM COAST, FL 32137 |
RF11067823 (Exp: 08/31/2027) | 386-569-4336 |
DESIDERIO CARLOS CARREIRO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/23/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 6/17/2025 - PREVIOUS INSPECTION NOTES Exterior both sides: 1. Please install set screws (permanent) at backflow valves on all Hose bibbs. FBCR P2902.4.3 2. Please raise ODU pads, require 3" clearence from surrounding ground. FBCR M1305.1.4.1 3. Bath vent stacks (2) on back roof require 6" above roof. FBCR P3103.1.1 4. Bath exhaust termination in soffit requires min 36" from operable window. M1506.3 5. Please extend down spouts to min 12" discharge from foundation wall. FBCR 318.5 Side A: Missing Receptacle behind door in Middle bedroom. Per plan. | |||
| BLD - BUILDING FINAL | 06/23/2025 | FINAL APPROVED | JSTEWART |
| Note: New inspection due to canceled inspection 6/17/2025 - PREVIOUS INSPECTION NOTES Exterior both sides: 1. Please install set screws (permanent) at backflow valves on all Hose bibbs. FBCR P2902.4.3 2. Please raise ODU pads, require 3" clearence from surrounding ground. FBCR M1305.1.4.1 3. Bath vent stacks (2) on back roof require 6" above roof. FBCR P3103.1.1 4. Bath exhaust termination in soffit requires min 36" from operable window. M1506.3 5. Please extend down spouts to min 12" discharge from foundation wall. FBCR 318.5 Side A: Missing Receptacle behind door in Middle bedroom. Per plan. | |||
| BLD - BUILDING FINAL | 06/17/2025 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 06/17/2025 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Exterior both sides: 1. Please install set screws (permanent) at backflow valves on all Hose bibbs. FBCR P2902.4.3 2. Please raise ODU pads, require 3" clearence from surrounding ground. FBCR M1305.1.4.1 3. Bath vent stacks (2) on back roof require 6" above roof. FBCR P3103.1.1 4. Bath exhaust termination in soffit requires min 36" from operable window. M1506.3 5. Please extend down spouts to min 12" discharge from foundation wall. FBCR 318.5 Side A: Missing Receptacle behind door in Middle bedroom. Per plan. | |||
| ROW - FINAL INSPECTION | 06/11/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 06/11/2025 | FINAL APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 06/09/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/09/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/09/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| BLD - BUILDING FINAL | 06/09/2025 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 05/06/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 05/06/25 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC - EARLY POWER | 04/25/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Surge Protection at main disconnects need to be installed prior to Final. NEC 230.67 Authorize release of email to FPL. | |||
| GRAVITY SEWER TEST | 04/15/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 04/15/2025 | APPROVED | MGIBSON |
| U-CROSS CONNECTION | 04/15/2025 | APPROVED | DHANEY |
| PEP TANK INSTALLATION REQUEST | 02/27/2025 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 02/13/2025 | APPROVED | FWILLIS |
| FIREWALL FINAL | 02/12/2025 | APPROVED | FWILLIS |
| INSULATION | 02/10/2025 | APPROVED | FWILLIS |
| Note: 2/10/25 - ITEMS CORRECTED Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 2/5/2025 1:43:36 PM *** Side A: need a Nail plate at kitchen wall (mid height) Side B: 1. Missing lug at breaker panel service terminal. 2. Master bath exhaust assembly not wired, romex appears to be short. will look at insulation. | |||
| ALL ROUGH | 02/05/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 2/5/2025 1:43:36 PM *** Side A: need a Nail plate at kitchen wall (mid height) Side B: 1. Missing lug at breaker panel service terminal. 2. Master bath exhaust assembly not wired, romex appears to be short. will look at insulation. | |||
| FIREWALL FRAMING | 02/05/2025 | APPROVED | FWILLIS |
| FIREWALL DRYWALL NAILING | 02/03/2025 | APPROVED | FWILLIS |
| WALL SHEATHING | 02/03/2025 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/07/2025 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 01/07/2025 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 12/18/2024 | APPROVED | MCONTRYMAN |
| FOUND SURVEY APPROVED (OFFICE) | 12/18/2024 | APPROVED | LSALYERDS |
| MONOLITHIC SLAB | 11/27/2024 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/22/2024 | APPROVED | MGIBSON |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/21/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 09/30/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/11/2025 | 06/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/30/2025 | 02/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/17/2024 | 12/18/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/17/2024 | 12/17/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/19/2024 | 11/21/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/12/2024 | 11/18/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit certification letter 2. Reports need to be digitally signed and sealed. | |||
| ZON | COMPLETE | 09/10/2024 | 09/10/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/10/2024 | 09/16/2024 |
| Note: Released By: JPI | |||
| ZON | HOLD | 09/06/2024 | 09/06/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM One tree must be a shade tree Must have a minimum of 16 foundation plantings with at least 8 in the front and 4 along left side and 6 along the side facing the street Please clearly specify which shrubs you are using on landscape plan | |||
| BLD | HOLD | 09/06/2024 | 09/07/2024 |
| Note: Held By: JPI 1. Based on an internet inquiry, the following product approval number appears to have recently expired, please cure. FL 17676 (Windows - Single Hung non impact +35/-50) | |||
| BLD | COMPLETE | 08/19/2024 | 08/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/12/2024 | 08/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Disregard building hold you are allowed to defer submit for truss package | |||
| BLD | HOLD | 08/12/2024 | 08/16/2024 |
| Note: Held By: JPI 1. Delayed submittal for truss package not approved. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp. | |||
| CUSVC | COMPLETE | 08/12/2024 | 08/13/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/12/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/12/2024 | 08/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/12/2024 | 08/15/2024 |
| LOCATE | COMPLETE | 08/12/2024 | 08/14/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/12/2024 | 08/16/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/12/2024 | 08/12/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | HOLD | 08/12/2024 | 08/14/2024 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM 1. Lot layout on landscape plan doesn't match. 2. Landscape plan missing 2 more trees. 1 tree = 2500 square feet. | |||
| BADMIN | HOLD | 08/12/2024 | 08/12/2024 |
| Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM subcontractors will need to be added after reviews have been completed. | |||
| SWALE | COMPLETE | 08/12/2024 | 10/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/23/2025 |
| CONNECTION FEES | ¤2,374.52 | 09/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/17/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/17/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 09/17/2024 |
| IMPACT FEE FIRE | ¤856.18 | 09/17/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 09/17/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 09/17/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 09/17/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 09/17/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 09/17/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/17/2024 |
| SURCHARGE FS 533.721 | ¤17.01 | 09/17/2024 |
| SURCHARGE - FS 468.631 | ¤25.52 | 09/17/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/17/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/17/2024 |
| SW ENG PRE APRON | ¤30.00 | 09/17/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/17/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/17/2024 |
| SEWER CREDIT | (¤1,700.00) | 09/17/2024 |
| SEWER INSPECTION | ¤25.00 | 09/17/2024 |
| SEWER CAPITAL FACILITY | ¤12,241.04 | 09/17/2024 |
| WATER CAPITAL FACILITY FEE | ¤8,702.28 | 09/17/2024 |
| SITE PLAN 30 | ¤30.00 | 09/17/2024 |
| WATER- TURN ON | ¤50.00 | 09/17/2024 |
| ADJUSTMENT 10% | (¤189.03) | 09/17/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/17/2024 |
| INSPECTION - RESIDENTIAL | ¤1,449.25 | 09/17/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤411.06 | 09/17/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤43,329.01 |