Permit #2024080495

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00130-0170
Total Square Footage: 2133 sqft
Block: 00130
Subdivision: 7024 -
Job Phone: 844-885-8913
Location Address: 13 PRINCE ANTHONY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/29/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE STE 430

THE WOODLANDS, TX 77380

Lot: 0170
Contracted Stated Job Value: ¤318,627.00
Job Description: Single Family Residence
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/09/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2025 12:05:26 PM *** 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1
BLD - BUILDING FINAL 04/09/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2025 2:52:46 PM *** 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1
BLD - BUILDING FINAL 04/08/2025 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/8/2025 3:41:59 PM *** 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1
U -UTILITY RESIDENTIAL FINAL 04/07/2025 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 04/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/7/2025 12:33:07 PM *** 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1
U-CROSS CONNECTION 04/07/2025 APPROVED - AS NOTED LFITZGERALD
Note: irr meter PVB-no cc
ROW - FINAL APRON (AFTER POUR) 04/02/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/02/2025 APPROVED TPOLACEK
Note: 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation
ROW FIELD SURVEY /GRADING CERTIFICATION 04/02/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 04/02/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/26/2025 Disapproved - NO FEE TPOLACEK
Note: 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation
ELECTRIC - EARLY POWER 03/13/2025 APPROVED CVANSTRAHLEN
ROW- PRE-APRON (PRE-POUR) 02/13/2025 APPROVED - AS NOTED TPOLACEK
Note: 02/13/25 TPOLACEK*** NEED TO MAKE SURE AT THE MITER END OF CULVERT THE FORMS MUST BE 9" TO THE SIDE OF THE CULVERT BOTH SIDES ARE ONLY 6" AND MUST BE RESET. CULVERT ELEVATION IS GOOD. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
GRAVITY SEWER TEST 02/11/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 02/11/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
LATH/BRICK/ WATER BARRIER 02/03/2025 APPROVED MCONTRYMAN
Note: 2/3/25 Water barrier approved Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26.
INSULATION 02/03/2025 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26.
ALL ROUGH 01/29/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26.
ALL ROUGH 01/28/2025 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 1/28/2025 9:30:47 AM *** 1/28/25: Cancelled by Applicant via text at @ 09:26.
ELECTRIC-TUG 01/17/2025 APPROVED MCONTRYMAN
Note: 1/17/25 Okay to release e-mail to FPL
ROOF VALLEY & METAL 01/02/2025 APPROVED RSIMS
WALL SHEATHING 12/31/2024 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/31/2024 APPROVED - AS NOTED MCONTRYMAN
Note: 12/31/24 1. 2 areas on roof sheathing need to be corrected. Both areas are heaving at the seams. Superintendent and framer are aware and going to have fixed
TIE BEAM / LINTEL 12/18/2024 CANCELLED BY INSPECTOR RSIMS
Note: *** NOTES ADDED BY RSIMS 12/18/2024 10:33:20 AM *** 12/18/24: Per plans this is a fully wood framed house so this inspection is not required. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 12/11/2024 12:41:13 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
GRAVITY SEWER TEST 12/18/2024 CANCELLED BY APPLICANT WEB
SEWER TIE IN 12/18/2024 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 12/16/2024 APPROVED LSALYERDS
MONOLITHIC SLAB 12/11/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/11/2024 12:41:13 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
PLUMBING 1ST ROUGH UNDERGROUND 12/09/2024 APPROVED MGIBSON
Note: 12/6/2024 - PREVIOUS INSPECTION NOTES SPOKE TO AJ FROM LGI
PLUMBING 1ST ROUGH UNDERGROUND 12/06/2024 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE TO AJ FROM LGI
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 12/05/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 10/31/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 03/12/2025 03/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 03/10/2025 03/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
BLD COMPLETE 01/30/2025 01/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 01/27/2025 01/27/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 01/22/2025 01/27/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
ENGIN1 COMPLETE 12/13/2024 12/16/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 12/13/2024 12/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 12/03/2024 12/03/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Upload geotech test results
BLD COMPLETE 12/03/2024 12/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 12/02/2024 12/02/2024
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please rename your file name to Geo Report. No names or numbers.
MECH COMPLETE 10/23/2024 10/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 10/08/2024 10/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition
BLD COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 08/20/2024 08/20/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 08/13/2024 10/08/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 08/12/2024 08/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/12/2024 08/16/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. FL 38057 revision number is expired. 2. FL 11473 revision number is expired 3. All plan sheet must be separated 4. Plan sheets say they are not for construction or permitting. Submit correct plans
CUSVC COMPLETE 08/12/2024 08/13/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 08/12/2024 08/16/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans say not for construction or permitting. Submit correct plans
ENGIN1 COMPLETE 08/12/2024 08/13/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/12/2024 08/15/2024
LOCATE COMPLETE 08/12/2024 08/14/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 08/12/2024 08/15/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
SW1 COMPLETE 08/12/2024 08/13/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON HOLD 08/12/2024 08/14/2024
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please separate floor and elevations plans for zoning to review AC pad location on floor plan does not match site and landscape plans

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/10/2025
REINSPECTION RESIDENTIAL ¤40.00 04/10/2025
CONNECTION FEES ¤1,187.26 10/29/2024
FC IMPACT FEE EMS ¤62.00 10/29/2024
IMPACT FEE FIRE ¤434.51 10/29/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/29/2024
FC IMPACT FEE LIBRARY ¤268.00 10/29/2024
IMPACT FEE PARKS ¤1,828.01 10/29/2024
IMPACT FEE SCHOOL ¤5,450.00 10/29/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 10/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/29/2024
SURCHARGE FS 533.721 ¤10.40 10/29/2024
SURCHARGE - FS 468.631 ¤15.60 10/29/2024
SW ENG - FOUNDATION SURVEY ¤20.00 10/29/2024
SW ENG INSPECTION 80 ¤80.00 10/29/2024
SW ENG PRE APRON ¤30.00 10/29/2024
SW ENG - REVIEW 20 ¤20.00 10/29/2024
SW ENG RES REVIEW 200 ¤200.00 10/29/2024
SEWER CREDIT (¤1,466.00) 10/29/2024
SEWER INSPECTION ¤25.00 10/29/2024
SEWER CAPITAL FACILITY ¤6,120.52 10/29/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 10/29/2024
SITE PLAN 30 ¤30.00 10/29/2024
WATER-METER ¤514.49 10/29/2024
WATER- TURN ON ¤25.00 10/29/2024
WATER- TURN ON ¤25.00 10/29/2024
ADJUSTMENT 10% (¤115.58) 10/29/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/29/2024
INSPECTION - RESIDENTIAL ¤877.25 10/29/2024
PLAN REVIEW - RESIDENTIAL ¤248.59 10/29/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,473.69