I want to search for...
Permit #2024080495
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00130-0170 |
| Total Square Footage: 2133 sqft |
| Block: 00130 |
| Subdivision: 7024 - |
| Job Phone: 844-885-8913 |
| Location Address: 13 PRINCE ANTHONY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/29/2024 |
| NOC: RECORDED |
| Applicant name: SIMON DALE VANWAGENEN |
| Owner: LGI HOMES-FLORIDA LLC |
|
Address 1450 LAKE ROBBINS DRIVE STE 430 THE WOODLANDS, TX 77380 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤318,627.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
LGI HOMES-FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2304 SPRING HILL CT TAMPA, FL 33602 |
CBC1257972 (Exp: 08/31/2026) | 904-451-8258 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/09/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/9/2025 12:05:26 PM *** 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1 | |||
| BLD - BUILDING FINAL | 04/09/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/9/2025 2:52:46 PM *** 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1 | |||
| BLD - BUILDING FINAL | 04/08/2025 | PARTIALLY APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/8/2025 3:41:59 PM *** 4/8/25: Previously listed item 9 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1 | |||
| U -UTILITY RESIDENTIAL FINAL | 04/07/2025 | FINAL APPROVED | LFITZGERALD |
| BLD - BUILDING FINAL | 04/07/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/7/2025 12:33:07 PM *** 4/7/25: 1). Water Heater: MC raceway needs to be sealed where it enters the wall. FBC [A]107.4 2). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 3) AHU: Supply & return ductes need to be sealed fully at garage ceiling area. FBC-R302.11 / FBC EC TABLE R402.4.1.1 4). Kitchen counter wall outlet acnnot be on the Small Appliance circuits. NEC-210.52 (3)(C) 5). Low voltage panel in Laundry rm.: Unused opening needs to be capped off (tape is not approved). NEC 408.7 Hole where low voltage enters the top needs to be sealed properly per FBC-R302.11 6). LFMC at ODU needs to be secured within 12" of disconnect. NEC 350.30(A) 7). Exterior outlets are not working - GFCI protected. Tester shows reversed hot and neutral. 8). Wall outlet on the right side wall behind the sink counter must be GFCI protected because it is within 6ft. of water. (cannot be on Small Appliance circuit). NEC 210.8(A)(7) 9). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 10) Master bathroom: right side sink is leaking from the drain. FBC-P2503.1 | |||
| U-CROSS CONNECTION | 04/07/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: irr meter PVB-no cc | |||
| ROW - FINAL APRON (AFTER POUR) | 04/02/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/02/2025 | APPROVED | TPOLACEK |
| Note: 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/02/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 04/02/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/26/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation | |||
| ELECTRIC - EARLY POWER | 03/13/2025 | APPROVED | CVANSTRAHLEN |
| ROW- PRE-APRON (PRE-POUR) | 02/13/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02/13/25 TPOLACEK*** NEED TO MAKE SURE AT THE MITER END OF CULVERT THE FORMS MUST BE 9" TO THE SIDE OF THE CULVERT BOTH SIDES ARE ONLY 6" AND MUST BE RESET. CULVERT ELEVATION IS GOOD. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| GRAVITY SEWER TEST | 02/11/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 02/11/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 02/03/2025 | APPROVED | MCONTRYMAN |
| Note: 2/3/25 Water barrier approved Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26. | |||
| INSULATION | 02/03/2025 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26. | |||
| ALL ROUGH | 01/29/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/29/2025 1:19:19 PM *** 1/29/25: Approved as noted. 1). SGD is not installed. Waiting on delivery. Check at insulation. FBC [A]107.4 2). FPA revision for windows and doors is only accepted at the time of this inspection. Check for approval at insulation. FBC [A]107.4 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25: Cancelled by Applicant via text at @ 09:26. | |||
| ALL ROUGH | 01/28/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/28/2025 9:30:47 AM *** 1/28/25: Cancelled by Applicant via text at @ 09:26. | |||
| ELECTRIC-TUG | 01/17/2025 | APPROVED | MCONTRYMAN |
| Note: 1/17/25 Okay to release e-mail to FPL | |||
| ROOF VALLEY & METAL | 01/02/2025 | APPROVED | RSIMS |
| WALL SHEATHING | 12/31/2024 | APPROVED | MCONTRYMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/31/2024 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 12/31/24 1. 2 areas on roof sheathing need to be corrected. Both areas are heaving at the seams. Superintendent and framer are aware and going to have fixed | |||
| TIE BEAM / LINTEL | 12/18/2024 | CANCELLED BY INSPECTOR | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/18/2024 10:33:20 AM *** 12/18/24: Per plans this is a fully wood framed house so this inspection is not required. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 12/11/2024 12:41:13 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. | |||
| GRAVITY SEWER TEST | 12/18/2024 | CANCELLED BY APPLICANT | WEB |
| SEWER TIE IN | 12/18/2024 | CANCELLED BY APPLICANT | WEB |
| FOUND SURVEY APPROVED (OFFICE) | 12/16/2024 | APPROVED | LSALYERDS |
| MONOLITHIC SLAB | 12/11/2024 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/11/2024 12:41:13 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/09/2024 | APPROVED | MGIBSON |
| Note: 12/6/2024 - PREVIOUS INSPECTION NOTES SPOKE TO AJ FROM LGI | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/06/2024 | CANCELLED BY APPLICANT | MGIBSON |
| Note: SPOKE TO AJ FROM LGI | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 12/05/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 10/31/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/12/2025 | 03/13/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/10/2025 | 03/10/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| BLD | COMPLETE | 01/30/2025 | 01/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/27/2025 | 01/27/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/22/2025 | 01/27/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| ENGIN1 | COMPLETE | 12/13/2024 | 12/16/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/13/2024 | 12/13/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/03/2024 | 12/03/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Upload geotech test results | |||
| BLD | COMPLETE | 12/03/2024 | 12/05/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 12/02/2024 | 12/02/2024 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please rename your file name to Geo Report. No names or numbers. | |||
| MECH | COMPLETE | 10/23/2024 | 10/28/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/08/2024 | 10/09/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition | |||
| BLD | COMPLETE | 10/08/2024 | 10/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/08/2024 | 10/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/20/2024 | 08/20/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/13/2024 | 10/08/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/12/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2024 | 08/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. FL 38057 revision number is expired. 2. FL 11473 revision number is expired 3. All plan sheet must be separated 4. Plan sheets say they are not for construction or permitting. Submit correct plans | |||
| CUSVC | COMPLETE | 08/12/2024 | 08/13/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 08/12/2024 | 08/16/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans say not for construction or permitting. Submit correct plans | |||
| ENGIN1 | COMPLETE | 08/12/2024 | 08/13/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/12/2024 | 08/15/2024 |
| LOCATE | COMPLETE | 08/12/2024 | 08/14/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2024 | 08/15/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition | |||
| SW1 | COMPLETE | 08/12/2024 | 08/13/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | HOLD | 08/12/2024 | 08/14/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please separate floor and elevations plans for zoning to review AC pad location on floor plan does not match site and landscape plans |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 04/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/10/2025 |
| CONNECTION FEES | ¤1,187.26 | 10/29/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 10/29/2024 |
| IMPACT FEE FIRE | ¤434.51 | 10/29/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 10/29/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 10/29/2024 |
| IMPACT FEE PARKS | ¤1,828.01 | 10/29/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 10/29/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 10/29/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/29/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/29/2024 |
| SURCHARGE FS 533.721 | ¤10.40 | 10/29/2024 |
| SURCHARGE - FS 468.631 | ¤15.60 | 10/29/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/29/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/29/2024 |
| SW ENG PRE APRON | ¤30.00 | 10/29/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/29/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/29/2024 |
| SEWER CREDIT | (¤1,466.00) | 10/29/2024 |
| SEWER INSPECTION | ¤25.00 | 10/29/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 10/29/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 10/29/2024 |
| SITE PLAN 30 | ¤30.00 | 10/29/2024 |
| WATER-METER | ¤514.49 | 10/29/2024 |
| WATER- TURN ON | ¤25.00 | 10/29/2024 |
| WATER- TURN ON | ¤25.00 | 10/29/2024 |
| ADJUSTMENT 10% | (¤115.58) | 10/29/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/29/2024 |
| INSPECTION - RESIDENTIAL | ¤877.25 | 10/29/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤248.59 | 10/29/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤22,473.69 |