I want to search for...
Permit #2024080566
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7001-00100-0180 |
| Block: 00100 |
| Subdivision: 7001 - |
| Job Phone: 717-307-6845 |
| Location Address: 10 FEDERAL LN |
| Type: DR - DRIVEWAY |
| Issue Date: 08/28/2024 |
| NOC: Unknown |
| Applicant name: JARRETT D LEHMAN |
| Owner: FATIMA SENA |
|
Address 10 FEDERAL LANE PALM COAST, FL 32137 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤2,375.00 |
| Job Description: Concrete Driveway |
| Type: CN |
Contractor
SALT FORCE CONCRETE & OUTDOOR CUSTOMS INC
| Status | Location Address | Phone |
| CANCEL |
9979 AMOS AVE HASTINGS, FL 32145 |
386-302-3262 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 12/03/2024 | APPROVED | EMADISON |
| ROW - FINAL INSPECTION | 12/03/2024 | APPROVED | EMADISON |
| U -UTILITY RESIDENTIAL FINAL | 12/03/2024 | FINAL APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 11/06/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: THIS INSPECTION IS AFTER ALL PAVERS ARE LAID AND HOT PATCH DONE. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/06/2024 | APPROVED | PFLANAGAN |
| Note: READY TO LAY PAVERS ----------------------------------------------------------------- 10/29/2024 - PREVIOUS INSPECTION NOTES READY TO POUR THE APRON AND THE PAVER RESTRAINTS ONLY BEFORE NEXT PRE POUR INSPECTION ALL BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. -------------------------------------------------------------------------------- 10/25/2024 - PREVIOUS INSPECTION NOTES THE LEFT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL. THE PAVER DETAIL DOESN'T MATCH THE FIELD. PAVER DETAIL IN THE SYSTEM SHOWS JUST FOOTERS IN THE RIGHT OF WAY. --------------------------------------------------------------------------------- ** 08/29/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW- PAVER RESTRAINTS | 10/29/2024 | APPROVED | PFLANAGAN |
| Note: ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/29/2024 | PARTIALLY APPROVED | PFLANAGAN |
| Note: READY TO POUR THE APRON AND THE PAVER RESTRAINTS ONLY BEFORE NEXT PRE POUR INSPECTION ALL BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. -------------------------------------------------------------------------------- 10/25/2024 - PREVIOUS INSPECTION NOTES THE LEFT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL. THE PAVER DETAIL DOESN'T MATCH THE FIELD. PAVER DETAIL IN THE SYSTEM SHOWS JUST FOOTERS IN THE RIGHT OF WAY. --------------------------------------------------------------------------------- ** 08/29/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW- PRE-APRON (PRE-POUR) | 10/25/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE LEFT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL. THE PAVER DETAIL DOESN'T MATCH THE FIELD. PAVER DETAIL IN THE SYSTEM SHOWS JUST FOOTERS IN THE RIGHT OF WAY. --------------------------------------------------------------------------------- ** 08/29/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW- PRE-APRON (PRE-POUR) | 08/29/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/29/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 10/21/2024 | 10/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 10/21/2024 | 10/29/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/21/2024 | 10/21/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement for recording | |||
| ZON | COMPLETE | 10/21/2024 | 10/21/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/14/2024 | 08/16/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 08/14/2024 | 08/21/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/14/2024 | 08/14/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 12/02/2024 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/02/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/28/2024 |
| SITE PLAN 15 | ¤15.00 | 08/28/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 08/28/2024 |
| SW ENG PRE APRON | ¤30.00 | 08/28/2024 |
| ADJUSTMENT 10% | (¤3.00) | 08/28/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/28/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤386.00 |