I want to search for...

Permit #2024080593

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7024-00180-0030
GARAGE: 490 sqft
OPENED PORCH (WITH ROOF) : 219 sqft
CONDITIONED SPACE: 1693 sqft
Total Square Footage: 2402 sqft
Block: 00180
Subdivision: -
Job Phone: 844-885-8913
Location Address: 27 PRINCE KAAREL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/29/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE

THE WOODLANDS, TX 77380

Address

STE 430

THE WOODLANDS, TX 77380

Lot: 0030
Contracted Stated Job Value: ¤232,878.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
GRAVITY SEWER TEST 06/15/2026 RSIMS
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: Cancelled by Applicant via text at @ 1554.
SEWER TIE IN 06/15/2026 RSIMS
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: Cancelled by Applicant via text at @ 1554.
INSULATION 05/27/2026 APPROVED CVANSTRAHLEN
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES Windows and doors need to be foamed. New inspection due to canceled inspection Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/19/2026 10:46:07 AM *** Code for Nail plates is NEC 300.4 *** NOTES ADDED BY RSIMS 5/19/2026 10:27:10 AM *** 5/19/26: Check at Insulation Inspection 1). Front entry door is not installed. 2). Missing 1 of 2 Gable end bracing requires (2) GBC clips. marked on plans. FBC [A]107.4 3). Nail,plates required for top plate penetrations for wires at 7 locations. Stugs marked NP. 4). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from vault peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 5). 2 straps at back left wall need nails into stud. Stud marked Clavos. 6). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 7). Bathroom exhausts are missing strap. FBC-M1502.4.2 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 5/18/26: 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
INSULATION 05/26/2026 Disapproved - NO FEE PKNAPIK
Note: Windows and doors need to be foamed. New inspection due to canceled inspection Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/19/2026 10:46:07 AM *** Code for Nail plates is NEC 300.4 *** NOTES ADDED BY RSIMS 5/19/2026 10:27:10 AM *** 5/19/26: Check at Insulation Inspection 1). Front entry door is not installed. 2). Missing 1 of 2 Gable end bracing requires (2) GBC clips. marked on plans. FBC [A]107.4 3). Nail,plates required for top plate penetrations for wires at 7 locations. Stugs marked NP. 4). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from vault peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 5). 2 straps at back left wall need nails into stud. Stud marked Clavos. 6). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 7). Bathroom exhausts are missing strap. FBC-M1502.4.2 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 5/18/26: 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
GRAVITY SEWER TEST 05/26/2026 CANCELLED BY APPLICANT PKNAPIK
Note: 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: Cancelled by Applicant via text at @ 1554.
SEWER TIE IN 05/26/2026 CANCELLED BY APPLICANT PKNAPIK
Note: 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26: Cancelled by Applicant via text at @ 1554.
INSULATION 05/22/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/19/2026 10:46:07 AM *** Code for Nail plates is NEC 300.4 *** NOTES ADDED BY RSIMS 5/19/2026 10:27:10 AM *** 5/19/26: Check at Insulation Inspection 1). Front entry door is not installed. 2). Missing 1 of 2 Gable end bracing requires (2) GBC clips. marked on plans. FBC [A]107.4 3). Nail,plates required for top plate penetrations for wires at 7 locations. Stugs marked NP. 4). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from vault peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 5). 2 straps at back left wall need nails into stud. Stud marked Clavos. 6). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 7). Bathroom exhausts are missing strap. FBC-M1502.4.2 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 5/18/26: 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
SEWER TIE IN 05/21/2026 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 3:55:32 PM *** 5/21/26: Cancelled by Applicant via text at @ 1554.
GRAVITY SEWER TEST 05/21/2026 CANCELLED BY APPLICANT RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 3:55:12 PM *** 5/21/26: Cancelled by Applicant via text at @ 1554.
LATH/BRICK/ WATER BARRIER 05/21/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 2:15:12 PM *** 5/21/26: Check at Insulation. 1). Front entry door has over 1/4" maximum shim space along top jamb that will require solid blocking along entire jamb. FBCR 609.1 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/19/2026 10:46:07 AM *** Code for Nail plates is NEC 300.4 *** NOTES ADDED BY RSIMS 5/19/2026 10:27:10 AM *** 5/19/26: Check at Insulation Inspection 1). Front entry door is not installed. 2). Missing 1 of 2 Gable end bracing requires (2) GBC clips. marked on plans. FBC [A]107.4 3). Nail,plates required for top plate penetrations for wires at 7 locations. Stugs marked NP. 4). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from vault peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 5). 2 straps at back left wall need nails into stud. Stud marked Clavos. 6). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 7). Bathroom exhausts are missing strap. FBC-M1502.4.2 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 5/18/26: 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
ALL ROUGH 05/19/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/19/2026 10:46:07 AM *** Code for Nail plates is NEC 300.4 *** NOTES ADDED BY RSIMS 5/19/2026 10:27:10 AM *** 5/19/26: Check at Insulation Inspection 1). Front entry door is not installed. 2). Missing 1 of 2 Gable end bracing requires (2) GBC clips. marked on plans. FBC [A]107.4 3). Nail,plates required for top plate penetrations for wires at 7 locations. Stugs marked NP. 4). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from vault peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 5). 2 straps at back left wall need nails into stud. Stud marked Clavos. 6). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 7). Bathroom exhausts are missing strap. FBC-M1502.4.2 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 5/18/26: 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 .. ** Scabbed stud pieces need to be full length to create the continuous load path that was eliminated by the cut studs on an exterior load bearing/sheer wall. 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4 Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
ELECTRIC-TUG 05/18/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/18/2026 9:24:42 AM *** 5/18/26: FPL emailed > Approved for TUG. Also, see notes added to Inspection 2420 from Inspection 2460 that remain unresolved.
WALL SHEATHING 05/06/2026 Disapproved - NO FEE RSIMS
Note: 5/5/26: 1. Remove water barrier from front of house so that exterior sheathing at that section can be checked.
WALL SHEATHING 05/06/2026 APPROVED - AS NOTED HCAMACHO
Note: Inspector Notes from Inspection 2460 *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/06/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/5/2026 2:34:59 PM *** 5/5/26: Check at next inspection. 1). studs cut at dttz tie downs at both back and front of the house need to be replaced to maintain 16" OC spread as required on plans. FBC [A]107.4 2). Gable end bracing requires GBC clip. marked on plans. FBC [A]107.4 3). Back lanai door missing LSTA strap. Marked on plans. FBC [A]107.4
ROOF VALLEY & METAL 05/06/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/5/2026 2:34:20 PM *** Approved
FOUND SURVEY APPROVED (OFFICE) 05/05/2026 APPROVED - AS NOTED PFLANAGAN
Note: FOUNDATION SURVEY HAS 2 BENCHMARKS ON IT. PASSING AS NOTED THAT THE ORIGINAL IS ON THERE AND THE BENCHMARKS HOPEFULLY MATCH EACH OTHER IF FOUNDATION IS OUT OF TOLERANCE IT WILL BE ON THE BUILDER.
MONOLITHIC SLAB 04/20/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/20/2026 10:33:55 AM *** Approved
PLUMBING 1ST ROUGH UNDERGROUND 04/17/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/17/2026 10:46:59 AM *** 4/17/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 12/16/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 10/31/2024 APPROVED CBOWERMASTER
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - STORMWATER FINAL
Note: *** INSPECTOR NOTE*** TIRES AND PLYWOOD ON LEFT SIDE SWALE ARE NOT FROM THE BUILDER. I DID NOTICE THEM WHEN I COMPLETED THE PRE POUR INSPECTIONS ACROSS THE STREET.
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL
ELECTRIC - EARLY POWER

Review History

Department Status Date In Date Out
SW1 HOLD 05/04/2026 05/04/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Benchmark does not match approved grading plan. Benchmark shall be maintained throughout construction cycle.
ZON COMPLETE 05/04/2026 05/04/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 05/04/2026 05/05/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/04/2026 05/04/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
MECH COMPLETE 04/28/2026 04/28/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/30/2025 01/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/10/2024 12/16/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 12/10/2024 12/10/2024
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please rename your file name to Geotech. No names or numbers.
BLD HOLD 12/03/2024 12/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Original report shows 3 test spots per lift. Only 2 test results done
MECH COMPLETE 10/23/2024 10/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 10/08/2024 10/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Design location on heatload needs to be Daytona Beach
BADMIN COMPLETE 08/14/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/14/2024 08/19/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans say not for construction or permitting. NO review done. 2. FL 38057, 11473 revision numbers are expired. Update to the most current code cycle 3. Plans need to be digitally signed and sealed.
CUSVC COMPLETE 08/14/2024 08/19/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 08/14/2024 08/19/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans are not for construction or permitting. NO review done 2. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 08/14/2024 08/14/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/14/2024 08/19/2024
LOCATE COMPLETE 08/14/2024 08/16/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 08/14/2024 08/19/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
SW1 COMPLETE 08/14/2024 08/14/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON COMPLETE 08/14/2024 08/14/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
SWALE COMPLETE 08/14/2024 10/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONNECTION FEES (¤233.75) 10/29/2024
CONNECTION FEES ¤1,187.26 10/29/2024
FC IMPACT FEE EMS ¤62.00 10/29/2024
IMPACT FEE FIRE ¤434.51 10/29/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/29/2024
FC IMPACT FEE LIBRARY ¤268.00 10/29/2024
IMPACT FEE PARKS ¤1,828.01 10/29/2024
IMPACT FEE SCHOOL ¤5,450.00 10/29/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 10/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/29/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/29/2024
SURCHARGE FS 533.721 ¤10.63 10/29/2024
SURCHARGE - FS 468.631 ¤15.94 10/29/2024
SW ENG - FOUNDATION SURVEY ¤20.00 10/29/2024
SW ENG INSPECTION 80 ¤80.00 10/29/2024
SW ENG PRE APRON ¤30.00 10/29/2024
SW ENG - REVIEW 20 ¤20.00 10/29/2024
SW ENG RES REVIEW 200 ¤200.00 10/29/2024
SEWER CREDIT (¤1,342.00) 10/29/2024
SEWER INSPECTION (¤25.00) 10/29/2024
SEWER INSPECTION ¤25.00 10/29/2024
SEWER CAPITAL FACILITY (¤48.00) 10/29/2024
SEWER CAPITAL FACILITY ¤6,120.52 10/29/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 10/29/2024
WATER CAPITAL FACILITY FEE (¤1,500.00) 10/29/2024
SITE PLAN 30 ¤30.00 10/29/2024
WATER-METER ¤514.49 10/29/2024
WATER- TURN ON ¤25.00 10/29/2024
WATER- TURN ON ¤25.00 10/29/2024
ADJUSTMENT 10% (¤118.08) 10/29/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/29/2024
INSPECTION - RESIDENTIAL ¤896.50 10/29/2024
PLAN REVIEW - RESIDENTIAL ¤254.28 10/29/2024
PLAN REVIEW - REVISION ¤32.50
EXTENSION ¤40.00
EXTENSION ¤40.00
EXTENSION ¤40.00
ADMINISTRATIVE - EXTENSION ¤40.00
Fees Total Due: ¤192.50 Total Paid: ¤20,741.45