I want to search for...

Permit #2024080608

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00130-0180
GARAGE: 490 sqft
PATIO/DECK (NO ROOF) : 219 sqft
CONDITIONED SPACE: 1693 sqft
Total Square Footage: 2402 sqft
Block: 00130
Subdivision: -
Job Phone: 844-885-8913
Location Address: 11 PRINCE ANTHONY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/28/2024
NOC: RECORDED
Applicant name: SIMON DALE VANWAGENEN
Owner: LGI HOMES-FLORIDA LLC

Address

1450 LAKE ROBBINS DRIVE STE 430

THE WOODLANDS, TX 77380

Lot: 0180
Contracted Stated Job Value: ¤232,878.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

LGI HOMES-FLORIDA LLC
Status Location Address State License Number Phone
ACTIVE

2304 SPRING HILL CT

TAMPA, FL 33602

CBC1257972 (Exp: 08/31/2026) 904-451-8258

Sub Contractors

BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
CHRISTOPHER DENNIS O'CONNER
Status Location Address State License Number Phone
ACTIVE

240 N LAKE CUNNINGHAM AVE

JACKSONVILLE, FL 32257

ER13015361 (Exp: 08/31/2026) 904-540-0858
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/09/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2025 12:05:04 PM *** 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 5 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/25: I removed the previous item 3 concerning exterior outlets as that item was for 13 Prince Anthony and not 11 Prince Anthony. The existing items are correctly listed including #3 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Perimeter of dryer box needs to be sealed, FBC EC TABLE R402.4.1.1 2). Low voltage box in laundry room: Need to have hole at low voltage fire stopped - FBC-R302.11 and FMC conduit needs a cap for the unused opening. NEC 408.7 3). Wall outlet on the back of the kitchen island cannot be on the small appliance circuit. Kitchen island wall outlets installed under counters must be separate from small appliance circuits.210.52(B)(2) 4). Range is not engaged into anti-tip bracket. Could nopt properly test. FBC-[A]110.5 / FBCR M1901.2 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) 6). Access panel in garage is not flush with trim as required (due to foreign item holding it up). FBC EC TABLE R402.4.1.1 7). Water heater relief valve discharge pipe is less than 6" from finished grade as required. FBC-P504.7.2 8). Main Meter Panel: Needs to be sealed at the top to prevent water infiltration. FBC [A]107.4 Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 2/6/2025 11:25:13 AM *** 2/6/25: Back and left side walls covered with siding and trim however all visible water barrier is installed correctly. Remaining is Builders responsibility. 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
BLD - BUILDING FINAL 04/09/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2025 2:52:33 PM *** 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: Previous listed deficiency remains unresolved. 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. FBC-A] 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 4/8/2025 - PREVIOUS INSPECTION NOTES 4/8/25: Previously listed item 5 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/25: I removed the previous item 3 concerning exterior outlets as that item was for 13 Prince Anthony and not 11 Prince Anthony. The existing items are correctly listed including #3 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Perimeter of dryer box needs to be sealed, FBC EC TABLE R402.4.1.1 2). Low voltage box in laundry room: Need to have hole at low voltage fire stopped - FBC-R302.11 and FMC conduit needs a cap for the unused opening. NEC 408.7 3). Wall outlet on the back of the kitchen island cannot be on the small appliance circuit. Kitchen island wall outlets installed under counters must be separate from small appliance circuits.210.52(B)(2) 4). Range is not engaged into anti-tip bracket. Could nopt properly test. FBC-[A]110.5 / FBCR M1901.2 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) 6). Access panel in garage is not flush with trim as required (due to foreign item holding it up). FBC EC TABLE R402.4.1.1 7). Water heater relief valve discharge pipe is less than 6" from finished grade as required. FBC-P504.7.2 8). Main Meter Panel: Needs to be sealed at the top to prevent water infiltration. FBC [A]107.4 Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 2/6/2025 11:25:13 AM *** 2/6/25: Back and left side walls covered with siding and trim however all visible water barrier is installed correctly. Remaining is Builders responsibility. 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
BLD - BUILDING FINAL 04/08/2025 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/8/2025 3:41:30 PM *** 4/8/25: Previously listed item 5 is still under review due to new information presented by the Builder from the Manufacturer. Weep holes do not meet minimum code cited. FBC-P2705.1(3) - Where fixtures come in contact with walls and floors, the contact shall be water tight. 4/7/25: I removed the previous item 3 concerning exterior outlets as that item was for 13 Prince Anthony and not 11 Prince Anthony. The existing items are correctly listed including #3 4/7/2025 - PREVIOUS INSPECTION NOTES 4/7/25: 1). Perimeter of dryer box needs to be sealed, FBC EC TABLE R402.4.1.1 2). Low voltage box in laundry room: Need to have hole at low voltage fire stopped - FBC-R302.11 and FMC conduit needs a cap for the unused opening. NEC 408.7 3). Wall outlet on the back of the kitchen island cannot be on the small appliance circuit. Kitchen island wall outlets installed under counters must be separate from small appliance circuits.210.52(B)(2) 4). Range is not engaged into anti-tip bracket. Could nopt properly test. FBC-[A]110.5 / FBCR M1901.2 5). Guest bathroom tub needs tile sealed to tub fully. FBC-P2705.1(3) 6). Access panel in garage is not flush with trim as required (due to foreign item holding it up). FBC EC TABLE R402.4.1.1 7). Water heater relief valve discharge pipe is less than 6" from finished grade as required. FBC-P504.7.2 8). Main Meter Panel: Needs to be sealed at the top to prevent water infiltration. FBC [A]107.4 Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 2/6/2025 11:25:13 AM *** 2/6/25: Back and left side walls covered with siding and trim however all visible water barrier is installed correctly. Remaining is Builders responsibility. 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
BLD - BUILDING FINAL 04/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/7/2025 12:21:04 PM *** Disregard item 3 *** NOTES ADDED BY RSIMS 4/7/2025 12:07:45 PM *** 4/7/25: 1). Perimeter of dryer box needs to be sealed, FBC EC TABLE R402.4.1.1 2). Low voltage box in laundry room: Need to have hole at low voltage fire stopped - FBC-R302.11 and FMC conduit needs a cap for the unused opening. NEC 408.7 3). Exterior outlets are not working. Tester shows reversed hot & nuetral. NEC 210.8(A)(3). 4). Wall outlet on the back of the kitchen island cannot be on the small appliance circuit. Kitchen island wall outlets installed under counters must be separate from small appliance circuits.210.52(B)(2) 5). Range is not engaged into anti-tip bracket. Could nopt properly test. FBC-[A]110.5 / FBCR M1901.2 6). Guest bathroom tub needs tile sealed to tub fully and tub apron sealed at the floor. FBC-P2705.1(3) 7). Access panel in garage is not flush with trim as required (due to foreign item holding it up). FBC EC TABLE R402.4.1.1 8). Water heater relief valve discharge pipe is less than 6" from finished grade as required. FBC-P504.7.2 9). Main Meter Panel: Needs to be sealed at the top to prevent water infiltration. FBC [A]107.4 Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 2/6/2025 11:25:13 AM *** 2/6/25: Back and left side walls covered with siding and trim however all visible water barrier is installed correctly. Remaining is Builders responsibility. 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
U-CROSS CONNECTION 04/07/2025 APPROVED - AS NOTED LFITZGERALD
Note: irrigation meter plus PVB-no cc
U -UTILITY RESIDENTIAL FINAL 04/07/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/02/2025 APPROVED TPOLACEK
Note: 3/26/2025 - PREVIOUS INSPECTION NOTES 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation
ROW FIELD SURVEY /GRADING CERTIFICATION 04/02/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 04/02/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL APRON (AFTER POUR) 04/02/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PROJECT STATUS 03/31/2025 APPROVED GBERTOLA
Note: Parren was there yesterday
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/26/2025 Disapproved - NO FEE TPOLACEK
Note: 03/26/25 TPOLACEK*** RIGHT SIDE EDGE OF PAVEMENT IS HIGHER THAN THE DRAINAGE CONVEYANCE ALONG RIGHT SIDE OF PROPERTY TO THE MIDDLE OF THE STRUCTURE. THE BACK SIDE OF SWALE MUST BE EQUAL TO OR GREATER THAN EDGE OF PAVEMENT. EDGE OF PAVEMENT Section 300.01 C(3) V-16 Elevation at the front property line shall match the edge of pavement elevation
ELECTRIC - EARLY POWER 03/13/2025 APPROVED CVANSTRAHLEN
ROW- PRE-APRON (PRE-POUR) 02/13/2025 APPROVED - AS NOTED TPOLACEK
Note: 02/13/25 TPOLACEK*** SPOKE WITH PHIL AND HE KNOWS THEY HAVE TO HAVE THE RIGHT SIDE ROADBOARD MOVED TO THE 8' MARK THEY ALSO NEED TO MAKE SURE AT THE MITER END OF CULVERT THE FORMS MUST BE 9" TO THE SIDE OF THE CULVERT BOTH SIDES ARE ONLY 6" AND MUST BE RESET. CULVERT ELEVATION IS GOOD. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
GRAVITY SEWER TEST 02/11/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 02/11/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
LATH/BRICK/ WATER BARRIER 02/06/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/6/2025 11:25:13 AM *** 2/6/25: Back and left side walls covered with siding and trim however all visible water barrier is installed correctly. Remaining is Builders responsibility. 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
INSULATION 02/04/2025 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/4/2025 2:28:58 PM *** 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
INSULATION 02/03/2025 CANCELLED BY APPLICANT MCONTRYMAN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
LATH/BRICK/ WATER BARRIER 02/03/2025 CANCELLED BY APPLICANT MCONTRYMAN
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
ALL ROUGH 01/28/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/28/2025 1:26:15 PM *** 1/28/25: Approved as noted to keep project moving. ALL MUST BE COMPLETE PRIOR TO NEXT INSPECTION. Check at next inspection. 1). FPA code for installed windows and doors does not match the submitted FPA sheet. FBC [A]107.4 2). Smoke detector on vaulted ceiling outside of Owner's suite needs to be moved to the required location. Location marked with orange spray paint. NFPA 70 - 29.11.3.1 3). Bathtub needs to be filled to the overflow for testing. FBC-P312.1
ELECTRIC-TUG 01/17/2025 APPROVED MCONTRYMAN
Note: 1/17/25 Okay to release e-mail to FPL
ROOF VALLEY & METAL 01/02/2025 APPROVED RSIMS
WALL SHEATHING 12/31/2024 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/31/2024 APPROVED MCONTRYMAN
TIE BEAM / LINTEL 12/18/2024 CANCELLED BY INSPECTOR RSIMS
Note: *** NOTES ADDED BY RSIMS 12/18/2024 10:31:20 AM *** 12/18/24: Per plans this is a fully wood framed house so this inspection is not required. Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 12/11/2024 12:40:54 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
FOUND SURVEY APPROVED (OFFICE) 12/16/2024 APPROVED LSALYERDS
MONOLITHIC SLAB 12/11/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/11/2024 12:40:54 PM *** 12/11/24: At the time of Inspection all of the requirements for the Monolithic Slab as detailed on the plans and FL Building Code have been met. It is the sole responsibility of the Contractor to assure that everything remains the same.
PLUMBING 1ST ROUGH UNDERGROUND 12/09/2024 APPROVED MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 12/06/2024 CANCELLED BY INSPECTOR MGIBSON
Note: SPOKE TO AJ FROM LGI
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 12/05/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 10/31/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 03/12/2025 03/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 03/10/2025 03/10/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
BLD COMPLETE 01/30/2025 01/30/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 01/27/2025 01/27/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 01/27/2025 01/30/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. MI 3540 SHI FL# 41886 is not a fixed window. Please correct product approval.
MECH HOLD 01/22/2025 01/27/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
ENGIN1 COMPLETE 12/16/2024 12/16/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 12/16/2024 12/16/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 12/02/2024 12/05/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 10/23/2024 10/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/08/2024 10/09/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ELEC COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/08/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 10/08/2024 10/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Design location heatload needs to be daytona beach
ZON COMPLETE 10/08/2024 10/08/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SWALE COMPLETE 08/15/2024 10/09/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 08/14/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/14/2024 08/19/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans say not for construction or permitting. NO review done. 2. FL 38057, 11473 revision numbers are expired. Update to the most current code cycle 3. Plans need to be digitally signed and sealed.
CUSVC COMPLETE 08/14/2024 08/15/2024
Note: Released By: LUCY NABICO - -
ELEC HOLD 08/14/2024 08/19/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans say not for construction or permitting. NO review done 2. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 08/14/2024 08/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/14/2024 08/19/2024
LOCATE COMPLETE 08/14/2024 08/16/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH HOLD 08/14/2024 08/19/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
SW1 HOLD 08/14/2024 08/14/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide driveway apron width at edge of pavement
ZON COMPLETE 08/14/2024 08/15/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/10/2025
REINSPECTION RESIDENTIAL ¤40.00 04/10/2025
CONNECTION FEES ¤1,187.26 10/28/2024
FC IMPACT FEE EMS ¤62.00 10/28/2024
IMPACT FEE FIRE ¤434.51 10/28/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/28/2024
FC IMPACT FEE LIBRARY ¤268.00 10/28/2024
IMPACT FEE PARKS ¤1,828.01 10/28/2024
IMPACT FEE SCHOOL ¤5,450.00 10/28/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 10/28/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/28/2024
WATER -IRRIGATION INSPECTION ¤25.00 10/28/2024
SURCHARGE FS 533.721 ¤10.63 10/28/2024
SURCHARGE - FS 468.631 ¤15.94 10/28/2024
SW ENG - FOUNDATION SURVEY ¤20.00 10/28/2024
SW ENG INSPECTION 80 ¤80.00 10/28/2024
SW ENG PRE APRON ¤30.00 10/28/2024
SW ENG - REVIEW 20 ¤20.00 10/28/2024
SW ENG RES REVIEW 200 ¤200.00 10/28/2024
SEWER CREDIT (¤1,466.00) 10/28/2024
SEWER INSPECTION ¤25.00 10/28/2024
SEWER CAPITAL FACILITY ¤6,120.52 10/28/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 10/28/2024
SITE PLAN 30 ¤30.00 10/28/2024
WATER-METER ¤514.49 10/28/2024
WATER- TURN ON ¤25.00 10/28/2024
WATER- TURN ON ¤25.00 10/28/2024
ADJUSTMENT 10% (¤118.08) 10/28/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/28/2024
INSPECTION - RESIDENTIAL ¤896.50 10/28/2024
PLAN REVIEW - RESIDENTIAL ¤254.28 10/28/2024
Fees Total Due: ¤0.00 Total Paid: ¤22,496.70