I want to search for...

Permit #2024080609

Permit Details

Status: COED

Parcel Id: 06-12-31-5180-00000-0600
OPENED PORCH (WITH ROOF) : 160 sqft
GARAGE: 424 sqft
CONDITIONED SPACE: 2355 sqft
Total Square Footage: 2939 sqft
Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1
Job Phone: 904-669-7000
Location Address: 19 MAHOGANY WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/21/2024
NOC: RECORDED
Applicant name: PAUL GILBERT AXTELL
Owner: TOLL SOUTHEAST LP CO INC

Address

1140 VIRGINIA DRIVE

FORT WASHINGTON, PA 19034

Lot: 60
Contracted Stated Job Value: ¤189,832.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

TOLL BROS INC
Status Location Address State License Number Phone
ACTIVE

40 EVEREST LN, STE 5

ST JOHNS, FL 32259

CGC60445 (Exp: 08/31/2026) 904-217-3852

Sub Contractors

JAMES F QUINN III
Status Location Address State License Number Phone
ACTIVE

3210 SW 40TH BLVD STE F

GAINESVILLE, FL 32608

EC13010994 (Exp: 08/31/2026) 352-378-9274
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700
JAMES MICHAEL WATSON
Status Location Address State License Number Phone
INACTIVE

38115 YALE CIRCLE

LEESBURG, FL 34748

SCC131152841 (Exp: 08/31/2026) 352-434-0115

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/21/2025 FINAL APPROVED MCONTRYMAN
Note: 2/19/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES 2/13/25 1. Guest bath tub drain not holding water 2. Guest bath hot water is luke warm FBCR P2705.1 – 4 3. Tile to wall penetration needs to be sealed up in guest bath 4. Master shower hot water is luke warm FBCR P2705.1 – 4 5. Seal up around mantel for fireplace insert 6. Oven breaker will need a breaker lock since not installed 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25: Partial Inspection due to no electricity in house. * Checked the following: HVAC supply & return registers, model numbers and breakers/ drains/dishwasher hookup/dryer exhaust/ Hot water orientation (still need to check shower and bathtub faucets). 1). secondary disconnect near ODU has an unused opening. NEC 408.7 2). Hardi trim around rear columns needs to be finished (painted per Manufacturer's specs). FBC [A]107.4 3). Hole at low voltage in AHU closet needs to be sealed. FBC EC TABLE R402.4.1.1 All other items not listed need to be checked.
BLD - BUILDING FINAL 02/19/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: 2/13/2025 - PREVIOUS INSPECTION NOTES 2/13/25 1. Guest bath tub drain not holding water 2. Guest bath hot water is luke warm FBCR P2705.1 – 4 3. Tile to wall penetration needs to be sealed up in guest bath 4. Master shower hot water is luke warm FBCR P2705.1 – 4 5. Seal up around mantel for fireplace insert 6. Oven breaker will need a breaker lock since not installed 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25: Partial Inspection due to no electricity in house. * Checked the following: HVAC supply & return registers, model numbers and breakers/ drains/dishwasher hookup/dryer exhaust/ Hot water orientation (still need to check shower and bathtub faucets). 1). secondary disconnect near ODU has an unused opening. NEC 408.7 2). Hardi trim around rear columns needs to be finished (painted per Manufacturer's specs). FBC [A]107.4 3). Hole at low voltage in AHU closet needs to be sealed. FBC EC TABLE R402.4.1.1 All other items not listed need to be checked.
BLD - BUILDING FINAL 02/13/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 2/13/25 1. Guest bath tub drain not holding water 2. Guest bath hot water is luke warm FBCR P2705.1 – 4 3. Tile to wall penetration needs to be sealed up in guest bath 4. Master shower hot water is luke warm FBCR P2705.1 – 4 5. Seal up around mantel for fireplace insert 6. No light installed in attic NEC-210.70(2) 7. Oven breaker will need a breaker lock since not installed 2/12/2025 - PREVIOUS INSPECTION NOTES 2/12/25: Partial Inspection due to no electricity in house. * Checked the following: HVAC supply & return registers, model numbers and breakers/ drains/dishwasher hookup/dryer exhaust/ Hot water orientation (still need to check shower and bathtub faucets). 1). secondary disconnect near ODU has an unused opening. NEC 408.7 2). Hardi trim around rear columns needs to be finished (painted per Manufacturer's specs). FBC [A]107.4 3). Hole at low voltage in AHU closet needs to be sealed. FBC EC TABLE R402.4.1.1 All other items not listed need to be checked.
BLD - BUILDING FINAL 02/12/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 2/12/2025 10:16:59 AM *** 2/12/25: Partial Inspection due to no electricity in house. * Checked the following: HVAC supply & return registers, model numbers and breakers/ drains/dishwasher hookup/dryer exhaust/ Hot water orientation (still need to check shower and bathtub faucets). 1). secondary disconnect near ODU has an unused opening. NEC 408.7 2). Hardi trim around rear columns needs to be finished (painted per Manufacturer's specs). FBC [A]107.4 3). Hole at low voltage in AHU closet needs to be sealed. FBC EC TABLE R402.4.1.1 All other items not listed need to be checked.
U -UTILITY RESIDENTIAL FINAL 02/12/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 reclaim irr-no cross connection
ELECTRIC - EARLY POWER 02/05/2025 APPROVED MCONTRYMAN
Note: 2/5/25 Okay to release e-mail to FPL 2/3/2025 - PREVIOUS INSPECTION NOTES 2/3/25 1. Need blank covers in panel box where surge protector was taken out 2. GFCI under meter/main needs to be secured 3. Conduit for underground service needs to be secured to the house NEC 352.2 Inspector Notes from Inspection 2200 10/25/2024 1. Check fastener when sidding installed. 10/24/2024 - PREVIOUS INSPECTION NOTES 10 /24/2024 1. PVC conduit needs to be fastened. NEC 352.30 2. Outlet in sub panel needs to be labeled.
ELECTRIC - EARLY POWER 02/03/2025 Disapproved - NO FEE MCONTRYMAN
Note: 2/3/25 1. Need blank covers in panel box where surge protector was taken out 2. GFCI under meter/main needs to be secured 3. Conduit for underground service needs to be secured to the house NEC 352.2 Inspector Notes from Inspection 2200 10/25/2024 1. Check fastener when sidding installed. 10/24/2024 - PREVIOUS INSPECTION NOTES 10 /24/2024 1. PVC conduit needs to be fastened. NEC 352.30 2. Outlet in sub panel needs to be labeled.
U-CROSS CONNECTION 01/29/2025 APPROVED - AS NOTED LFITZGERALD
Note: reclaim irr-no cross connection
ROW - FINAL APRON (AFTER POUR) 01/08/2025 APPROVED FSLADISH
Note: 1/8/25 NO CHIPPED, CRACKED OR BROKEN CONCRETE OBSERVED AT THE TIME OF THIS INSPECTION.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/08/2025 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9270 12/20/24 BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/08/2025 APPROVED FSLADISH
Note: 1/8/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 01/08/2025 APPROVED FSLADISH
Note: 1/8/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PRE-APRON (PRE-POUR) 12/20/2024 APPROVED - AS NOTED FSLADISH
Note: 12/20/24 BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
GRAVITY SEWER TEST 12/17/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 12/17/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
WATER METER INSTALLATION REQUEST 11/12/2024 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 11/08/2024 APPROVED PKNAPIK
INSULATION 11/01/2024 APPROVED MCONTRYMAN
Note: 10/30/2024 - PREVIOUS INSPECTION NOTES 10/29/2024 - PREVIOUS INSPECTION NOTES 10/29/2024 1. Duct layout still does not match plans. FBC [A]107.4 2. Upstairs double window needs to be taped outside and foamed inside. Inspector Notes from Inspection 2420 10/22/2024 Check at insullation. 1. 2pt conection of bath fans. FBC M1601.4.1 2. Water pressure test. FBCR P2503.5 3. 5ft head test. FBCR P2503.7 4. Dryer vent box not installed. 5. Duct layout does not match plans. FBC [A]107.4 6. Anchors for sliders not visible.
INSULATION 10/30/2024 CANCELLED BY APPLICANT PKNAPIK
Note: 10/29/2024 - PREVIOUS INSPECTION NOTES 10/29/2024 1. Duct layout still does not match plans. FBC [A]107.4 2. Upstairs double window needs to be taped outside and foamed inside. Inspector Notes from Inspection 2420 10/22/2024 Check at insullation. 1. 2pt conection of bath fans. FBC M1601.4.1 2. Water pressure test. FBCR P2503.5 3. 5ft head test. FBCR P2503.7 4. Dryer vent box not installed. 5. Duct layout does not match plans. FBC [A]107.4 6. Anchors for sliders not visible.
INSULATION 10/29/2024 Disapproved -FEE REQUIRED PKNAPIK
Note: 10/29/2024 1. Duct layout still does not match plans. FBC [A]107.4 2. Upstairs double window needs to be taped outside and foamed inside. Inspector Notes from Inspection 2420 10/22/2024 Check at insullation. 1. 2pt conection of bath fans. FBC M1601.4.1 2. Water pressure test. FBCR P2503.5 3. 5ft head test. FBCR P2503.7 4. Dryer vent box not installed. 5. Duct layout does not match plans. FBC [A]107.4 6. Anchors for sliders not visible.
ELECTRIC-TUG 10/25/2024 APPROVED - AS NOTED PKNAPIK
Note: 10/25/2024 1. Check fastener when sidding installed. 10/24/2024 - PREVIOUS INSPECTION NOTES 10 /24/2024 1. PVC conduit needs to be fastened. NEC 352.30 2. Outlet in sub panel needs to be labeled.
ELECTRIC-TUG 10/24/2024 Disapproved - NO FEE PKNAPIK
Note: 10 /24/2024 1. PVC conduit needs to be fastened. NEC 352.30 2. Outlet in sub panel needs to be labeled.
ALL ROUGH 10/22/2024 APPROVED - AS NOTED PKNAPIK
Note: 10/22/2024 Check at insullation. 1. 2pt conection of bath fans. FBC M1601.4.1 2. Water pressure test. FBCR P2503.5 3. 5ft head test. FBCR P2503.7 4. Dryer vent box not installed. 5. Duct layout does not match plans. FBC [A]107.4 6. Anchors for sliders not visible.
ROOF VALLEY & METAL 10/04/2024 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/02/2024 APPROVED KSANDOE
Note: 9/27/2024 - PREVIOUS INSPECTION NOTES Not ready. No access to 2nd floor
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/27/2024 Disapproved -FEE REQUIRED KSANDOE
Note: Not ready. No access to 2nd floor
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/26/2024 CANCELLED BY APPLICANT WEB
WALL SHEATHING 09/25/2024 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 09/10/2024 APPROVED TBAKER
MONOLITHIC SLAB 09/05/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 08/30/2024 APPROVED MGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 01/14/2025 01/17/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 12/23/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 12/19/2024 12/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
MECH COMPLETE 11/01/2024 11/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 10/25/2024 10/29/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2023 8th Edition
ENGIN1 COMPLETE 09/10/2024 09/10/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/10/2024 09/10/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 09/06/2024 09/06/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 09/06/2024 09/10/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 08/20/2024 08/20/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 08/20/2024 08/20/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
URB COMPLETE 08/15/2024 08/15/2024
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BADMIN COMPLETE 08/14/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 08/14/2024 08/16/2024
Note: Released By: JPI
CUSVC COMPLETE 08/14/2024 08/15/2024
Note: Released By: LUCY NABICO - -
ELEC COMPLETE 08/14/2024 08/19/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/14/2024 08/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS COMPLETE 08/14/2024 08/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 08/14/2024 08/16/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
MECH COMPLETE 08/14/2024 08/19/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 08/14/2024 08/14/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Rear drainage must be shown with at least 6" drop from the structure within first 10' See revision clouds and note on site plan.
ZON COMPLETE 08/14/2024 08/15/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/20/2025
REINSPECTION RESIDENTIAL ¤40.00 02/14/2025
CONTRACTOR CHANGE ¤20.00 12/20/2024
PLAN REVIEW - REVISION ¤32.50 11/08/2024
REINSPECTION RESIDENTIAL ¤40.00 10/29/2024
REINSPECTION RESIDENTIAL ¤40.00 10/17/2024
WATER-METER ¤514.49 08/21/2024
WATER-METER ¤427.42 08/21/2024
ADJUSTMENT 10% (¤154.08) 08/21/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/21/2024
INSPECTION - RESIDENTIAL ¤1,177.00 08/21/2024
PLAN REVIEW - RESIDENTIAL ¤333.84 08/21/2024
CONNECTION FEES ¤25.00 08/21/2024
FC IMPACT FEE EMS ¤62.00 08/21/2024
IMPACT FEE FIRE ¤428.09 08/21/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/21/2024
FC IMPACT FEE LIBRARY ¤268.00 08/21/2024
IMPACT FEE PARKS ¤1,800.99 08/21/2024
IMPACT FEE SCHOOL ¤5,450.00 08/21/2024
IMPACT FEE TRANSPORTATION ¤3,404.00 08/21/2024
SURCHARGE FS 533.721 ¤13.87 08/21/2024
SURCHARGE - FS 468.631 ¤20.80 08/21/2024
SW ENG - FOUNDATION SURVEY ¤20.00 08/21/2024
SW ENG INSPECTION 80 ¤80.00 08/21/2024
SW ENG PRE APRON ¤30.00 08/21/2024
SW ENG - REVIEW 20 ¤20.00 08/21/2024
SW ENG RES REVIEW 200 ¤200.00 08/21/2024
SEWER INSPECTION ¤25.00 08/21/2024
SITE PLAN 30 ¤30.00 08/21/2024
Fees Total Due: ¤0.00 Total Paid: ¤14,636.92