Permit #2024080799
Permit Details
Status: FINAL
| Block: 00000 |
| Subdivision: 2334 - EVOLVE PALM COAST - SANDLAKE SUBDIVISION LOT 4 |
| Job Phone: 386-931-5710 |
| Location Address: 51 EVOLVE PKWY |
| Type: FU - FIRE UNDERGROUND |
| Issue Date: 09/04/2024 |
| NOC: RECORDED |
| Applicant name: CHELSEA MARIE BARNEY |
| Owner: EVOLVE PALM COAST LLC |
|
Address 2918-A MARTINVILLE ROAD GREENSBORO, NC 27408 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤11,000.00 |
| Job Description: Bldg 1100 Underground fire line with DCDA, in building riser and freestanding FDC. |
| Type: CN |
Contractor
4C'S TRUCKING & EXCAVATION INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 2682 BUNNELL, FL 32110 |
FPC15-000050 (Exp: 06/30/2026) | 386-437-1257 | 386-437-4468 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 01/16/2026 | FINAL APPROVED | RMARTIN |
| Note: 1/14/2026 - PREVIOUS INSPECTION NOTES 1/14/26 Need to have FDC sign installed and Fire Hydrant at building is not the correct hight. (Low) I spoke to Chelsea with 4C's and she is aware. 12/12/2025 - PREVIOUS INSPECTION NOTES 12/12/25 Need to have FDC sign installed and final landscape to correctly measure hight of Fire Hydrant and curb installed for that measurement as well. 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25 Need to take a look at plan details Page 1 note 13 for distance off curb and Page 8.1 Fdc detail on min. hights, Landscape needs to be completed to measure correct hight of FDC and hydrants. | |||
| FIRE FINAL | 01/14/2026 | Disapproved - NO FEE | RMARTIN |
| Note: 1/14/26 Need to have FDC sign installed and Fire Hydrant at building is not the correct hight. (Low) I spoke to Chelsea with 4C's and she is aware. 12/12/2025 - PREVIOUS INSPECTION NOTES 12/12/25 Need to have FDC sign installed and final landscape to correctly measure hight of Fire Hydrant and curb installed for that measurement as well. 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25 Need to take a look at plan details Page 1 note 13 for distance off curb and Page 8.1 Fdc detail on min. hights, Landscape needs to be completed to measure correct hight of FDC and hydrants. | |||
| FIRE FINAL | 12/12/2025 | Disapproved - NO FEE | RMARTIN |
| Note: 12/12/25 Need to have FDC sign installed and final landscape to correctly measure hight of Fire Hydrant and curb installed for that measurement as well. 11/5/2025 - PREVIOUS INSPECTION NOTES 11/5/25 Need to take a look at plan details Page 1 note 13 for distance off curb and Page 8.1 Fdc detail on min. hights, Landscape needs to be completed to measure correct hight of FDC and hydrants. | |||
| FIRE FINAL | 11/05/2025 | Disapproved - NO FEE | RMARTIN |
| Note: 11/5/25 Need to take a look at plan details Page 1 note 13 for distance off curb and Page 8.1 Fdc detail on min. hights, Landscape needs to be completed to measure correct hight of FDC and hydrants. | |||
| FIRE SYSTEM FLUSH | 02/13/2025 | APPROVED | RMARTIN |
| Note: 2/12/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 2/12/2025 1:20:37 PM *** FLUSHED FROM BACK FLOW TO BUILDING RISER ROOM, STILL NEED TO FLUSH FROM FDC TO RISER ROOM 2/11/2025 - PREVIOUS INSPECTION NOTES | |||
| FIRE SYSTEM FLUSH | 02/12/2025 | PARTIALLY APPROVED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 2/12/2025 1:20:37 PM *** FLUSHED FROM BACK FLOW TO BUILDING RISER ROOM, STILL NEED TO FLUSH FROM FDC TO RISER ROOM 2/11/2025 - PREVIOUS INSPECTION NOTES | |||
| FIRE SYSTEM FLUSH | 02/11/2025 | CANCELLED BY APPLICANT | RMARTIN |
| FIRE MAIN HYDROSTATIC/BACKFLOW PREVENTOR | 01/31/2025 | APPROVED | JMUNSON |
| Note: 1/29/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 5110 *** NOTES ADDED BY RMARTIN 12/4/2024 9:37:49 AM *** this was already inspected and passed Inspector Notes from Inspection 5110 *** NOTES ADDED BY RMARTIN 11/12/2024 10:38:04 AM *** underground and risers done | |||
| FIRE MAIN HYDROSTATIC/BACKFLOW PREVENTOR | 01/29/2025 | CANCELLED BY APPLICANT | RMARTIN |
| Note: Inspector Notes from Inspection 5110 *** NOTES ADDED BY RMARTIN 12/4/2024 9:37:49 AM *** this was already inspected and passed Inspector Notes from Inspection 5110 *** NOTES ADDED BY RMARTIN 11/12/2024 10:38:04 AM *** underground and risers done | |||
| FIRE MAIN PLACEMENT /SIZE/THRUST /BLOCKING | 12/04/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 12/4/2024 9:37:49 AM *** this was already inspected and passed Inspector Notes from Inspection 5110 *** NOTES ADDED BY RMARTIN 11/12/2024 10:38:04 AM *** underground and risers done | |||
| FIRE MAIN PLACEMENT /SIZE/THRUST /BLOCKING | 11/12/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 11/12/2024 10:38:04 AM *** underground and risers done |
Review History
| Department | Status | Date In | Date Out |
| FI1 | COMPLETE | 08/19/2024 | 09/03/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 08/19/2024 | 08/27/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤26.81) | 09/04/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 09/04/2024 |
| INSPECTION - FIRE COMMERCIAL | ¤66.60 | 09/04/2024 |
| PLAN REVIEW - COMMERCIAL | ¤126.50 | 09/04/2024 |
| SURCHARGE FS 533.721 | ¤2.41 | 09/04/2024 |
| SURCHARGE - FS 468.631 | ¤3.62 | 09/04/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 09/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤267.32 |