I want to search for...
Permit #2024080933
Permit Details
Status: COED
| Block: RP N |
| Subdivision: 2249 - ST JOE BUSINESS CENTER |
| Job Phone: 386-931-6577 |
| Location Address: 4984 PALM COAST PKWY NW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 01/14/2025 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: ST JOE BUSINESS CENTER INC |
|
Address 4 HICKORY DRIVE OLD BROOKVILLE, NY 11545 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤50,000.00 |
| Job Description: UNIT 8 - 9 D'MARIA RESTAURANT COMMERCIAL INTERIOR BUILD OUT |
| Type: CN |
Contractor
A PLUS HOME IMPROVEMENTS LLC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
306 S RAILROAD ST BUNNELL, FL 32110 |
CGC1519145 (Exp: 08/31/2026) | 386-931-6577 | 386-263-3331 |
Sub Contractors
RONALD D PIERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
480 SHAWLAKE ROAD PIERSON, FL 32180 |
LQ710 (Exp: 09/01/2027) | 386-559-7466 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
LILIANA MEI FELIPE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
13233 SW 13TH STREET MIAMI, FL 33135 |
CAC1820913 (Exp: 08/31/2026) | 786-780-8348 |
GREGORY ALLEN HENRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1332 SUNSET BLVD DAYTONA BEACH, FL 32117 |
EC13009193 (Exp: 08/31/2026) | 386-679-6908 |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 04/30/2026 | FINAL APPROVED | HCAMACHO |
| Note: 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Need to have a hood surppression permit for the hoods/building. This inspection will be signed off when all permits associated with the Unit buildout have been completed. | |||
| FIRE FINAL | 04/30/2026 | APPROVED | RMARTIN |
| Note: 4/24/2026 - PREVIOUS INSPECTION NOTES Need to apply for a Fire Surpression Permit for the hood. | |||
| U - UTILITY COMMERCIAL FINAL | 04/24/2026 | FINAL APPROVED | BHAINES |
| FIRE FINAL | 04/24/2026 | Disapproved - NO FEE | JMUNSON |
| Note: Need to apply for a Fire Surpression Permit for the hood. | |||
| BUILDING FINAL | 04/24/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Need to have a hood surppression permit for the hoods/building. This inspection will be signed off when all permits associated with the Unit buildout have been completed. | |||
| ELECTRIC FINAL | 04/17/2026 | APPROVED - AS NOTED | RMARTIN |
| Note: Electrical panel covers need to be on correctly, one outlet behind stove needs securing and need occupancy sensors in restrooms. by fire final Any changes to the electrical not per plan will need to have an approved revision by final inspection. Need to schedule HVAC rough inspection and obtain a Hood permit ASAP. | |||
| HVAC FINAL | 04/16/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 3140 1. Missing Dampners on the supply and return ducts. 2. Missing Plasma air purifiers on supply duct. *Will look at for it at Above Ceiling Inspection* | |||
| GAS FINAL | 04/16/2026 | APPROVED | HCAMACHO |
| Note: 8/15/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3240 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION BOND WIRE NOTB INSTALLED AND NO GUAGE PRESENT AT TIME OB INSPECTION | |||
| FIREWALL FINAL | 04/15/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 3470 3/31/26 will need to move fresh air by water heater by final and a couple boxes in kitchen above ceiling need knockouts closed up, check on final 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES | |||
| PLUMBING FINAL | 04/15/2026 | APPROVED | HCAMACHO |
| ABOVE CEILING | 03/31/2026 | APPROVED - AS NOTED | RMARTIN |
| Note: 3/31/26 will need to move fresh air by water heater by final and a couple boxes in kitchen above ceiling need knockouts closed up, check on final 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES | |||
| ABOVE CEILING | 03/26/2026 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES | |||
| ABOVE CEILING | 03/25/2026 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES | |||
| FRAMING | 02/25/2026 | APPROVED | HCAMACHO |
| Note: 8/15/2025 - PREVIOUS INSPECTION NOTES | |||
| HVAC ROUGH | 02/25/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Missing Dampners on the supply and return ducts. 2. Missing Plasma air purifiers on supply duct. *Will look at for it at Above Ceiling Inspection* | |||
| INSULATION | 02/25/2026 | APPROVED | HCAMACHO |
| Note: 8/15/2025 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL PENETRATIONS | 09/18/2025 | APPROVED | FWILLIS |
| Note: 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 - ON SITE AT 8:15AM. DOOR LOCKED NO ANSWER. LEFT SITE AT 8:30AM. 8/15/2025 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL PENETRATIONS | 09/12/2025 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 9/12/25 - ON SITE AT 8:15AM. DOOR LOCKED NO ANSWER. LEFT SITE AT 8:30AM. 8/15/2025 - PREVIOUS INSPECTION NOTES | |||
| ABOVE CEILING | 08/15/2025 | CANCELLED BY APPLICANT | JMUNSON |
| Note: 2/13/2025 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL NAILING | 08/15/2025 | CANCELLED BY APPLICANT | KSANDOE |
| INSULATION | 08/15/2025 | CANCELLED BY APPLICANT | KSANDOE |
| FIREWALL PENETRATIONS | 08/15/2025 | CANCELLED BY APPLICANT | KSANDOE |
| GAS FINAL | 08/15/2025 | Disapproved - NO FEE | MGIBSON |
| Note: Inspector Notes from Inspection 3240 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION BOND WIRE NOTB INSTALLED AND NO GUAGE PRESENT AT TIME OB INSPECTION | |||
| FRAMING | 08/15/2025 | CANCELLED BY APPLICANT | KSANDOE |
| PLUMBING 2ND ROUGH | 08/15/2025 | APPROVED | MGIBSON |
| HVAC ROUGH | 08/15/2025 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC 2ND ROUGH | 08/06/2025 | APPROVED - AS NOTED | RMARTIN |
| Note: Any changes to the electrical not per plan will need to have an approved revision by final inspection. Need to schedule HVAC rough inspection and obtain a Hood permit ASAP. | |||
| ELECTRIC 1ST ROUGH | 07/30/2025 | APPROVED | MKRASKI |
| FIREWALL FRAMING | 06/25/2025 | APPROVED | KSANDOE |
| MONOLITHIC SLAB | 06/17/2025 | APPROVED | KSANDOE |
| GAS ROUGH | 06/17/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION | |||
| PLUMBING 1ST ROUGH | 06/06/2025 | APPROVED | MGIBSON |
| Note: New inspection due to canceled inspection 4/16/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET | |||
| PLUMBING 1ST ROUGH | 06/04/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 4/16/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET | |||
| ELECTRIC 1ST ROUGH | 06/04/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 2/13/2025 - PREVIOUS INSPECTION NOTES Knocked on door, no answer, Doors locked need access for inspection FBC[A] 110.5 | |||
| PLUMBING 1ST ROUGH | 04/16/2025 | Disapproved - NO FEE | MGIBSON |
| Note: 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET | |||
| PLUMBING 1ST ROUGH | 02/13/2025 | CANCELLED BY APPLICANT | MGIBSON |
| Note: SPOKE TO CONTRACTOR | |||
| ELECTRIC 1ST ROUGH | 02/13/2025 | Disapproved - NO FEE | MKRASKI |
| Note: Knocked on door, no answer, Doors locked need access for inspection FBC[A] 110.5 | |||
| GAS ROUGH | 02/13/2025 | CANCELLED BY APPLICANT | MGIBSON |
| Note: SPOKE WITH CONTRACTOR | |||
| ABOVE CEILING | 02/13/2025 | CANCELLED BY APPLICANT | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 12/03/2025 | 12/04/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/16/2025 | 09/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/05/2025 | 09/15/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide ul listing for metacaulk pipe collar | |||
| FI1 | COMPLETE | 09/05/2025 | 09/15/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | CANCEL | 08/27/2025 | 08/27/2025 |
| Note: Canceled review after speaking with contractor | |||
| MECH | HOLD | 08/25/2025 | 08/26/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Equipment sizing ductwork and fresh air has to be done by the engineer of record. 2. Cannot use old equipment. Does not meet the Energy code. | |||
| PLUM | COMPLETE | 01/13/2025 | 01/14/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 01/13/2025 | 01/13/2025 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Per Nancy asked to reject plans submitted. | |||
| MECH | COMPLETE | 12/18/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 12/18/2024 | 12/18/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM GREASE INTERCEPTOR REVIEW | |||
| PLUM | HOLD | 12/18/2024 | 01/07/2025 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 3. ok 4. ok 5. ok 6. PARTIAL REPEAT COMMENT: - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608. (BACKFLOW PREVENTER IS REQUIRED FOR ICEMAKER) 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. Occupant load calculation not per FBC Table 1004.5 (OCCUPANT LOAD FOR DINING AREA IS BASED ON 15sft. REVISE CALCULATION TO SHOW CORRECT OCCUPANT LOAD AND PLUMBING FIXTURES. PER BUILDING OFFICIAL CANNOT USE FIXED SEATING IN CALCULATION) 8. OK | |||
| BLD | COMPLETE | 12/18/2024 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/29/2024 | 11/12/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. OK 2. OK PARTIAL REPEAT COMMENT: (SECOND REQUEST) 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023. (PROVIDE DETAILS ON PLASMA AIR EQUIPMENT TO BE INSTALLED TO REDUCE FRESH AIR REQUIREMENTS.) 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK SIDE NOTE: 10. Hood systems require separate permit by Mechanical contractor. (ON HOOD PERMIT ENGINEERING WILL BE REQUIRED TO SHOW CLEARANCE TO COMBUSTIBLES, WALL ASSEMBLIES AND OTHER ENGINEERING FOR HOODS. YOU CAN ADD THIS TO THIS PERMIT AND THE MECHANICAL CONTRACTOR CAN USE THE ENGINEERING FOR THEIR PERMIT, OTHERWISE IT WILL BE REQUIRED ON HOOD PERMIT) | |||
| BLD | HOLD | 10/29/2024 | 11/14/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM REPEAT COMMENTS - PLEASE RESPOND TO COMMENTS INDIVIDUALLY AND CLOUD CHANGES ON THE PLANS. 4. Yellow font on S-1 is illegible. Please change color. 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 Yellow font on S-1 is illegible. Please change color. 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 Yellow font on S-1 is illegible. Please change color. 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2 | |||
| PLUM | HOLD | 10/29/2024 | 11/13/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM Please respond to comments 2 - 8 below in a narrative form. Please cloud changes on newly submitted plans. 2. Ok - Info on Life safety plan. Rejected Cover sheet for reference to residential codes. 3. REPEAT COMMENT - Needs separate permit for grease interceptor and grease interceptor exemption form to determine eligibility for GB-250 4. REPEAT COMMENT - Specify materials for DWV FBCP 702.2. CPVC not allowed for sanitary lines. 5. NEW RELATED COMMENT - Specify materials for water distribution FBCP 605.3. Identify insulation in compliance with FBC 2304.12.5 foam-plastic insulation for use within 6 inches of grade to be used on hot water lines. 6. REPEAT COMMENT - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. Occupant load calculation not per FBC Table 1004.5 8. REPEAT COMMENT - Show plumbing riser diagram FBC A 107.3.5 identify location of items in number 6 above (backflow protection for potable water). | |||
| BADMIN | INFORMATION | 10/28/2024 | 10/28/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Plan sheets are to be submitted as individual pages and fiile namesare to be the plan sheet given name. Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator Revisions and corrections should follow the same criteria and should use the same name as the original originally identified. (no – new, revised, second submittal, updated) We recently sent an email requiring plans sheets to include a description when the design professional does not use industry standards when naming their sheets. typically, the sheet name will identify the type of sheet it is (A - architectural, M -mechanical, E - electrical, etc.) Please look at the document submittal requirements and add the description to your plan file names. | |||
| GAS | COMPLETE | 09/20/2024 | 10/01/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 09/20/2024 | 10/03/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. THE COMMENTS BELOW ARE REORGANIZED 1. Separate sheets in file Plans - 9-11-24 (2). Load and name individually. AHJ 2. Needs title page with Occupancy Type, Building Type, Etc. 3. REPEAT COMMENT - Needs separate permit for grease interceptor and grease interceptor exemption form to determine eligibility for GB-250 4. REPEAT COMMENT - Specify materials for DWV FBCP 702 5. REPEAT COMMENT - Specify materials for water distribution FBCP 605.3 6. REPEAT COMMENT - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. 8. REPEAT COMMENT - Show plumbing riser diagram FBC A 107.3.5 | |||
| BLD | HOLD | 09/20/2024 | 09/09/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM CORRECTED REVIEW COMMENTS FROM BLDG REVIEW 1 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements Please provide code analysis to determine minimum requirements for this tenant space to compy with FBCEB Chapter 10. 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Please remove reference to B occupancy. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated and loaded as individual files.. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please storage water heater on PD-100. FBC 107.3.5 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together. | |||
| BLD | HOLD | 09/20/2024 | 10/03/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. REPEAT COMMENTS - PLEASE RESPOND TO COMMENTS INDIVIDUALLY AND CLOUD CHANGES ON THE PLANS. REPEAT COMMENTS 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements Please provide code analysis to determine minimum requirements for this tenant space to compy with FBCEB Chapter 10. 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Please remove reference to B occupancy. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated and loaded as individual files.. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please storage water heater on PD-100. FBC 107.3.5 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together. | |||
| DSD | INFORMATION | 09/20/2024 | 09/22/2024 |
| Note: Marked INFORMATION By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Need to apply for liquor license. | |||
| ELEC | COMPLETE | 09/20/2024 | 09/30/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/20/2024 | 10/02/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. OK PARTIAL REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023. (PROVIDE ENTIRE HEATLOAD NOT JUST ONE PAGE) PARTIAL REPEAT COMMENT: 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023. (PROVIDE DETAILS ON PLASMA AIR EQUIPMENT TO BE INSTALLED TO REDUCE FRESH AIR REQUIREMENTS.) 4. OK 5. OK PARTIAL REPEAT COMMENT: 6. Provide equipment schedule and details for RTUs, Exhaust fans, ETC... per FBC Energy Conservation 2023. (REMOVE REFERENCE TO EXISTING EQUIPMENT AND PROVIDE EQUIPMENT THAT MEETS CURRENT ENERGY CODE. 14.3 SEER2. REVISE EQUIPMENT SCHEDULE) 7. OK REPEAT COMMENT: 8. Provide note on plans for means of balancing for all supply, return, fresh air and exhaust per Section 608 FBC Mechanical 2023 PARTIAL REPEAT COMMENT: 9. Provide duct layout showing supply, return, fresh air and exhaust 107.2.1( FRESH AIR AND EXHAUST DUCTWORK NOT SHOWN ON DUCT LAYOUT PLANS) SIDE NOTE: 10. Hood systems require separate permit by Mechanical contractor. (ON HOOD PERMIT ENGINEERING WILL BE REQUIRED TO SHOW CLEARANCE TO COMBUSTIBLES, WALL ASSEMBLIES AND OTHER ENGINEERING FOR HOODS. YOU CAN ADD THIS TO THIS PERMIT AND THE MECHANICAL CONTRACTOR CAN USE THE ENGINEERING FOR THEIR PERMIT, OTHERWISE IT WILL BE REQUIRED ON HOOD PERMIT) | |||
| BADMIN | INFORMATION | 09/20/2024 | 09/20/2024 |
| Note: Marked INFORMATION By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| BADMIN | INFORMATION | 09/12/2024 | 09/12/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please fill out the cancelation form | |||
| BADMIN | INFORMATION | 09/11/2024 | 09/11/2024 |
| Note: Marked INFORMATION By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM Please fill out Palm Coast form: https://copc-strapi-production.s3.amazonaws.com/Extension_Cancellation_Request_Form_25e83fb54d.pdf | |||
| BLD | HOLD | 08/21/2024 | 09/09/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction (wood, metal, drywall etc.) FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please reconcile. FBC 107.3.5 8. A seperate application is required for the fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together. | |||
| ELEC | HOLD | 08/21/2024 | 09/03/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans have to be seperated. 2. All kitchen outlets have to be GFCI protected. NEC 2020 210.8 (B) | |||
| FI1 | COMPLETE | 08/21/2024 | 09/05/2024 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/21/2024 | 09/04/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023 4. Provide note on plan for test and balance per C408.2.2 FBC Energy Conservation 2023 5. Provide ductwork details showing hanging, installation and volume dampers per Chapter 603 FBC Mechanical 2023 6. Provide equipment schedule and details for RTUs, Exhaust fans, ETC... per FBC Energy Conservation 2023 7. Provide note on plan showing smoke detectors mounted in supply side of RTU's per 606.2.1 FBC Mechanical 2023 8. Provide note on plans for means of balancing for all supply, return, fresh air and exhaust per Section 608 FBC Mechanical 2023 9. Provide duct layout showing supply, return, fresh air and exhaust 107.2.1 10. Hood systems require separate permit by Mechanical contractor Complete review was not completed. Additional comments may be generated after resubmittal | |||
| PLUM | HOLD | 08/21/2024 | 09/06/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Last documented use was a church. Change of Use/ Occupancy required. FBC EB 605, 1010 2. Seperate permit required for commercial grease trap. AHJ 3. Grease Interceptor Exemption Form required. Emailed to applicant. AHJ 4. Specify materials for DWV FBCP 702 5. Specify materials for water distribution FBCP 605.3 6. Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1 8. Show plumbing riser diagram FBC A 107.3.5 | |||
| UD1 | COMPLETE | 08/21/2024 | 08/27/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| DSD | HOLD | 08/21/2024 | 08/22/2024 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Provide number of seat at bar Need to apply for liquor license. | |||
| GAS | HOLD | 08/21/2024 | 09/05/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. There was no existing gas in previous occupancy. remove all refernce to existing and provide a gas riser diagram showing piping sizes, materials and appliance btu ratings. 2. List gas subcontactor 3. All plan pages need to be separated Complete review was not completed. Additional comments may be generated after resubmittal | |||
| GAS | HOLD | 08/21/2024 | 09/05/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW. DID NOT SEE RISER IN PLANS. 1. REMOVE ALL REFERENCE TO EXISTING 2. SEPARATE ALL PLAN PAGES |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 03/27/2026 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 03/25/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 01/28/2026 |
| CONTRACTOR CHANGE | ¤20.00 | 12/03/2025 |
| REINSPECTION - COMMERCIAL | ¤60.00 | 09/12/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 05/29/2025 |
| SURCHARGE FS 533.721 | ¤4.41 | 01/14/2025 |
| SURCHARGE - FS 468.631 | ¤6.62 | 01/14/2025 |
| SITE PLAN 30 | ¤30.00 | 01/14/2025 |
| ADJUSTMENT 10% | (¤49.00) | 01/14/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 01/14/2025 |
| INSPECTION COMMERCIAL | ¤350.00 | 01/14/2025 |
| PLAN REVIEW - COMMERCIAL | ¤65.00 | 01/14/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤722.03 |