I want to search for...

Permit #2024080933

Permit Details

Status: COED

Block: RP N
Subdivision: 2249 - ST JOE BUSINESS CENTER
Job Phone: 386-931-6577
Location Address: 4984 PALM COAST PKWY NW
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 01/14/2025
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: ST JOE BUSINESS CENTER INC

Address

4 HICKORY DRIVE

OLD BROOKVILLE, NY 11545

Lot: 0070
Contracted Stated Job Value: ¤50,000.00
Job Description: UNIT 8 - 9 D'MARIA RESTAURANT COMMERCIAL INTERIOR BUILD OUT
Type: CN

Contractor

A PLUS HOME IMPROVEMENTS LLC
Status Location Address State License Number Phone Fax
ACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CGC1519145 (Exp: 08/31/2026) 386-931-6577 386-263-3331

Sub Contractors

RONALD D PIERSON
Status Location Address State License Number Phone
ACTIVE

480 SHAWLAKE ROAD

PIERSON, FL 32180

LQ710 (Exp: 09/01/2027) 386-559-7466
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
LILIANA MEI FELIPE
Status Location Address State License Number Phone
INACTIVE

13233 SW 13TH STREET

MIAMI, FL 33135

CAC1820913 (Exp: 08/31/2026) 786-780-8348
GREGORY ALLEN HENRY
Status Location Address State License Number Phone
ACTIVE

1332 SUNSET BLVD

DAYTONA BEACH, FL 32117

EC13009193 (Exp: 08/31/2026) 386-679-6908

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 04/30/2026 FINAL APPROVED HCAMACHO
Note: 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Need to have a hood surppression permit for the hoods/building. This inspection will be signed off when all permits associated with the Unit buildout have been completed.
FIRE FINAL 04/30/2026 APPROVED RMARTIN
Note: 4/24/2026 - PREVIOUS INSPECTION NOTES Need to apply for a Fire Surpression Permit for the hood.
U - UTILITY COMMERCIAL FINAL 04/24/2026 FINAL APPROVED BHAINES
FIRE FINAL 04/24/2026 Disapproved - NO FEE JMUNSON
Note: Need to apply for a Fire Surpression Permit for the hood.
BUILDING FINAL 04/24/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Need to have a hood surppression permit for the hoods/building. This inspection will be signed off when all permits associated with the Unit buildout have been completed.
ELECTRIC FINAL 04/17/2026 APPROVED - AS NOTED RMARTIN
Note: Electrical panel covers need to be on correctly, one outlet behind stove needs securing and need occupancy sensors in restrooms. by fire final Any changes to the electrical not per plan will need to have an approved revision by final inspection. Need to schedule HVAC rough inspection and obtain a Hood permit ASAP.
HVAC FINAL 04/16/2026 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 3140 1. Missing Dampners on the supply and return ducts. 2. Missing Plasma air purifiers on supply duct. *Will look at for it at Above Ceiling Inspection*
GAS FINAL 04/16/2026 APPROVED HCAMACHO
Note: 8/15/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3240 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION BOND WIRE NOTB INSTALLED AND NO GUAGE PRESENT AT TIME OB INSPECTION
FIREWALL FINAL 04/15/2026 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 3470 3/31/26 will need to move fresh air by water heater by final and a couple boxes in kitchen above ceiling need knockouts closed up, check on final 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES
PLUMBING FINAL 04/15/2026 APPROVED HCAMACHO
ABOVE CEILING 03/31/2026 APPROVED - AS NOTED RMARTIN
Note: 3/31/26 will need to move fresh air by water heater by final and a couple boxes in kitchen above ceiling need knockouts closed up, check on final 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES
ABOVE CEILING 03/26/2026 Disapproved -FEE REQUIRED RMARTIN
Note: 3/26/26 No work done, still need to suppoert all boxes in ceiling and close up all un-used openings 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES
ABOVE CEILING 03/25/2026 Disapproved -FEE REQUIRED RMARTIN
Note: 3/25/26 All boxes need to be supported above ceiling PER NEC 314.23 also all un-used openings in boxes need to be closed up NEC 110.12 8/15/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES
FRAMING 02/25/2026 APPROVED HCAMACHO
Note: 8/15/2025 - PREVIOUS INSPECTION NOTES
HVAC ROUGH 02/25/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Missing Dampners on the supply and return ducts. 2. Missing Plasma air purifiers on supply duct. *Will look at for it at Above Ceiling Inspection*
INSULATION 02/25/2026 APPROVED HCAMACHO
Note: 8/15/2025 - PREVIOUS INSPECTION NOTES
FIREWALL PENETRATIONS 09/18/2025 APPROVED FWILLIS
Note: 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 - ON SITE AT 8:15AM. DOOR LOCKED NO ANSWER. LEFT SITE AT 8:30AM. 8/15/2025 - PREVIOUS INSPECTION NOTES
FIREWALL PENETRATIONS 09/12/2025 Disapproved -FEE REQUIRED FWILLIS
Note: 9/12/25 - ON SITE AT 8:15AM. DOOR LOCKED NO ANSWER. LEFT SITE AT 8:30AM. 8/15/2025 - PREVIOUS INSPECTION NOTES
ABOVE CEILING 08/15/2025 CANCELLED BY APPLICANT JMUNSON
Note: 2/13/2025 - PREVIOUS INSPECTION NOTES
FIREWALL NAILING 08/15/2025 CANCELLED BY APPLICANT KSANDOE
INSULATION 08/15/2025 CANCELLED BY APPLICANT KSANDOE
FIREWALL PENETRATIONS 08/15/2025 CANCELLED BY APPLICANT KSANDOE
GAS FINAL 08/15/2025 Disapproved - NO FEE MGIBSON
Note: Inspector Notes from Inspection 3240 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION BOND WIRE NOTB INSTALLED AND NO GUAGE PRESENT AT TIME OB INSPECTION
FRAMING 08/15/2025 CANCELLED BY APPLICANT KSANDOE
PLUMBING 2ND ROUGH 08/15/2025 APPROVED MGIBSON
HVAC ROUGH 08/15/2025 CANCELLED BY APPLICANT WEB
ELECTRIC 2ND ROUGH 08/06/2025 APPROVED - AS NOTED RMARTIN
Note: Any changes to the electrical not per plan will need to have an approved revision by final inspection. Need to schedule HVAC rough inspection and obtain a Hood permit ASAP.
ELECTRIC 1ST ROUGH 07/30/2025 APPROVED MKRASKI
FIREWALL FRAMING 06/25/2025 APPROVED KSANDOE
MONOLITHIC SLAB 06/17/2025 APPROVED KSANDOE
GAS ROUGH 06/17/2025 APPROVED - AS NOTED MGIBSON
Note: 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CONTRACTOR BOND WIRE NEEDED AT GAS LINE AND RAN BACK TO PANEL, WILL LOOK AT GUAGE AT NEXT INSPECTION
PLUMBING 1ST ROUGH 06/06/2025 APPROVED MGIBSON
Note: New inspection due to canceled inspection 4/16/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET
PLUMBING 1ST ROUGH 06/04/2025 CANCELLED BY APPLICANT WEB
Note: 4/16/2025 - PREVIOUS INSPECTION NOTES 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET
ELECTRIC 1ST ROUGH 06/04/2025 CANCELLED BY APPLICANT WEB
Note: 2/13/2025 - PREVIOUS INSPECTION NOTES Knocked on door, no answer, Doors locked need access for inspection FBC[A] 110.5
PLUMBING 1ST ROUGH 04/16/2025 Disapproved - NO FEE MGIBSON
Note: 2/13/2025 - PREVIOUS INSPECTION NOTES SPOKE TO CONTRACTOR. MEET WITH C/M AND HE SAID HE WAS NOT READY YET
PLUMBING 1ST ROUGH 02/13/2025 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE TO CONTRACTOR
ELECTRIC 1ST ROUGH 02/13/2025 Disapproved - NO FEE MKRASKI
Note: Knocked on door, no answer, Doors locked need access for inspection FBC[A] 110.5
GAS ROUGH 02/13/2025 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE WITH CONTRACTOR
ABOVE CEILING 02/13/2025 CANCELLED BY APPLICANT RMARTIN

Review History

Department Status Date In Date Out
ELEC COMPLETE 12/03/2025 12/04/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/16/2025 09/17/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 09/05/2025 09/15/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide ul listing for metacaulk pipe collar
FI1 COMPLETE 09/05/2025 09/15/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH CANCEL 08/27/2025 08/27/2025
Note: Canceled review after speaking with contractor
MECH HOLD 08/25/2025 08/26/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Equipment sizing ductwork and fresh air has to be done by the engineer of record. 2. Cannot use old equipment. Does not meet the Energy code.
PLUM COMPLETE 01/13/2025 01/14/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 01/13/2025 01/13/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Per Nancy asked to reject plans submitted.
MECH COMPLETE 12/18/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
UD1 COMPLETE 12/18/2024 12/18/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM GREASE INTERCEPTOR REVIEW
PLUM HOLD 12/18/2024 01/07/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 3. ok 4. ok 5. ok 6. PARTIAL REPEAT COMMENT: - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608. (BACKFLOW PREVENTER IS REQUIRED FOR ICEMAKER) 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. Occupant load calculation not per FBC Table 1004.5 (OCCUPANT LOAD FOR DINING AREA IS BASED ON 15sft. REVISE CALCULATION TO SHOW CORRECT OCCUPANT LOAD AND PLUMBING FIXTURES. PER BUILDING OFFICIAL CANNOT USE FIXED SEATING IN CALCULATION) 8. OK
BLD COMPLETE 12/18/2024 01/06/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 10/29/2024 11/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. OK 2. OK PARTIAL REPEAT COMMENT: (SECOND REQUEST) 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023. (PROVIDE DETAILS ON PLASMA AIR EQUIPMENT TO BE INSTALLED TO REDUCE FRESH AIR REQUIREMENTS.) 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK SIDE NOTE: 10. Hood systems require separate permit by Mechanical contractor. (ON HOOD PERMIT ENGINEERING WILL BE REQUIRED TO SHOW CLEARANCE TO COMBUSTIBLES, WALL ASSEMBLIES AND OTHER ENGINEERING FOR HOODS. YOU CAN ADD THIS TO THIS PERMIT AND THE MECHANICAL CONTRACTOR CAN USE THE ENGINEERING FOR THEIR PERMIT, OTHERWISE IT WILL BE REQUIRED ON HOOD PERMIT)
BLD HOLD 10/29/2024 11/14/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM REPEAT COMMENTS - PLEASE RESPOND TO COMMENTS INDIVIDUALLY AND CLOUD CHANGES ON THE PLANS. 4. Yellow font on S-1 is illegible. Please change color. 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 Yellow font on S-1 is illegible. Please change color. 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 Yellow font on S-1 is illegible. Please change color. 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2
PLUM HOLD 10/29/2024 11/13/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM Please respond to comments 2 - 8 below in a narrative form. Please cloud changes on newly submitted plans. 2. Ok - Info on Life safety plan. Rejected Cover sheet for reference to residential codes. 3. REPEAT COMMENT - Needs separate permit for grease interceptor and grease interceptor exemption form to determine eligibility for GB-250 4. REPEAT COMMENT - Specify materials for DWV FBCP 702.2. CPVC not allowed for sanitary lines. 5. NEW RELATED COMMENT - Specify materials for water distribution FBCP 605.3. Identify insulation in compliance with FBC 2304.12.5 foam-plastic insulation for use within 6 inches of grade to be used on hot water lines. 6. REPEAT COMMENT - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. Occupant load calculation not per FBC Table 1004.5 8. REPEAT COMMENT - Show plumbing riser diagram FBC A 107.3.5 identify location of items in number 6 above (backflow protection for potable water).
BADMIN INFORMATION 10/28/2024 10/28/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Plan sheets are to be submitted as individual pages and fiile namesare to be the plan sheet given name. Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Given sheet name A.1 / Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator Revisions and corrections should follow the same criteria and should use the same name as the original originally identified. (no – new, revised, second submittal, updated) We recently sent an email requiring plans sheets to include a description when the design professional does not use industry standards when naming their sheets. typically, the sheet name will identify the type of sheet it is (A - architectural, M -mechanical, E - electrical, etc.) Please look at the document submittal requirements and add the description to your plan file names.
GAS COMPLETE 09/20/2024 10/01/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 09/20/2024 10/03/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. THE COMMENTS BELOW ARE REORGANIZED 1. Separate sheets in file Plans - 9-11-24 (2). Load and name individually. AHJ 2. Needs title page with Occupancy Type, Building Type, Etc. 3. REPEAT COMMENT - Needs separate permit for grease interceptor and grease interceptor exemption form to determine eligibility for GB-250 4. REPEAT COMMENT - Specify materials for DWV FBCP 702 5. REPEAT COMMENT - Specify materials for water distribution FBCP 605.3 6. REPEAT COMMENT - Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. REPEAT COMMENT - A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1. Please recalculate. 8. REPEAT COMMENT - Show plumbing riser diagram FBC A 107.3.5
BLD HOLD 09/20/2024 09/09/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM CORRECTED REVIEW COMMENTS FROM BLDG REVIEW 1 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements Please provide code analysis to determine minimum requirements for this tenant space to compy with FBCEB Chapter 10. 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Please remove reference to B occupancy. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated and loaded as individual files.. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please storage water heater on PD-100. FBC 107.3.5 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together.
BLD HOLD 09/20/2024 10/03/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. REPEAT COMMENTS - PLEASE RESPOND TO COMMENTS INDIVIDUALLY AND CLOUD CHANGES ON THE PLANS. REPEAT COMMENTS 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements Please provide code analysis to determine minimum requirements for this tenant space to compy with FBCEB Chapter 10. 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Please remove reference to B occupancy. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated and loaded as individual files.. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. Did it contain any electrical wiring? Specify location FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction from Table 601. FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please storage water heater on PD-100. FBC 107.3.5 8. A separate application is required for the kitchen exhaust hood fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together.
DSD INFORMATION 09/20/2024 09/22/2024
Note: Marked INFORMATION By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Need to apply for liquor license.
ELEC COMPLETE 09/20/2024 09/30/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 09/20/2024 10/02/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. OK PARTIAL REPEAT COMMENT: 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023. (PROVIDE ENTIRE HEATLOAD NOT JUST ONE PAGE) PARTIAL REPEAT COMMENT: 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023. (PROVIDE DETAILS ON PLASMA AIR EQUIPMENT TO BE INSTALLED TO REDUCE FRESH AIR REQUIREMENTS.) 4. OK 5. OK PARTIAL REPEAT COMMENT: 6. Provide equipment schedule and details for RTUs, Exhaust fans, ETC... per FBC Energy Conservation 2023. (REMOVE REFERENCE TO EXISTING EQUIPMENT AND PROVIDE EQUIPMENT THAT MEETS CURRENT ENERGY CODE. 14.3 SEER2. REVISE EQUIPMENT SCHEDULE) 7. OK REPEAT COMMENT: 8. Provide note on plans for means of balancing for all supply, return, fresh air and exhaust per Section 608 FBC Mechanical 2023 PARTIAL REPEAT COMMENT: 9. Provide duct layout showing supply, return, fresh air and exhaust 107.2.1( FRESH AIR AND EXHAUST DUCTWORK NOT SHOWN ON DUCT LAYOUT PLANS) SIDE NOTE: 10. Hood systems require separate permit by Mechanical contractor. (ON HOOD PERMIT ENGINEERING WILL BE REQUIRED TO SHOW CLEARANCE TO COMBUSTIBLES, WALL ASSEMBLIES AND OTHER ENGINEERING FOR HOODS. YOU CAN ADD THIS TO THIS PERMIT AND THE MECHANICAL CONTRACTOR CAN USE THE ENGINEERING FOR THEIR PERMIT, OTHERWISE IT WILL BE REQUIRED ON HOOD PERMIT)
BADMIN INFORMATION 09/20/2024 09/20/2024
Note: Marked INFORMATION By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.)
BADMIN INFORMATION 09/12/2024 09/12/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please fill out the cancelation form
BADMIN INFORMATION 09/11/2024 09/11/2024
Note: Marked INFORMATION By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM Please fill out Palm Coast form: https://copc-strapi-production.s3.amazonaws.com/Extension_Cancellation_Request_Form_25e83fb54d.pdf
BLD HOLD 08/21/2024 09/09/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Change of Use within an occupancy type - last documented occupancy was a church - increase in hazard. Definitions FBC 202, FBC 605, FBC, EB Chapter 10 [A] CHANGE OF OCCUPANCY. Any of the following shall be considered as a change of occupancy where the current Florida Building Code, Building requires a greater degree of accessibility, structural strength, fire protection, means of egress, safety, ventilation or sanitation than is existing in the current building or structure: 1. Any change in the occupancy classification of a building or structure. 2. Any change in the purpose of, or a change in the level of activity within, a building or structure. 3. A change of use. [A] CHANGE OF USE. A change in the use of a building or a portion of a building, within the same group classification, for which there is a change in application of the code requirements 2. There are two code analysis. B Occupancy on page A-1 does not apply to a restaurant with 49+ occupants. Life Safety Plan indicated Occupancy A-2. Please reconcile. FBC A 107.3.5 3. Plan sheets need to be separated. AHJ 4. Tables on S-1 are per IRC. Please replace with 2023 FBC, Building. Remove all references to residential construction. AHJ 5. Provide details on wall that was removed from space prior to permitting. FBC 107.3.5 6. Specify materials to be used in wall and ceiling construction (wood, metal, drywall etc.) FBC 107.3.5 7. Is the natural gas water heater a storage type as indicated pictorially or is it tankless? Please reconcile. FBC 107.3.5 8. A seperate application is required for the fire suppression system. FBC 904.2.2 9. Requires 2nd exit 1/3 the diagonal distance of the building from the first, if the building is sprinkled and 1/2 diagonal distance if it is not. It appears that the 2 exits in the front are too close together.
ELEC HOLD 08/21/2024 09/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans have to be seperated. 2. All kitchen outlets have to be GFCI protected. NEC 2020 210.8 (B)
FI1 COMPLETE 08/21/2024 09/05/2024
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
MECH HOLD 08/21/2024 09/04/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Energy Calculations per C407 FBC Energy Conservation 2023 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2023 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2023 4. Provide note on plan for test and balance per C408.2.2 FBC Energy Conservation 2023 5. Provide ductwork details showing hanging, installation and volume dampers per Chapter 603 FBC Mechanical 2023 6. Provide equipment schedule and details for RTUs, Exhaust fans, ETC... per FBC Energy Conservation 2023 7. Provide note on plan showing smoke detectors mounted in supply side of RTU's per 606.2.1 FBC Mechanical 2023 8. Provide note on plans for means of balancing for all supply, return, fresh air and exhaust per Section 608 FBC Mechanical 2023 9. Provide duct layout showing supply, return, fresh air and exhaust 107.2.1 10. Hood systems require separate permit by Mechanical contractor Complete review was not completed. Additional comments may be generated after resubmittal
PLUM HOLD 08/21/2024 09/06/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Last documented use was a church. Change of Use/ Occupancy required. FBC EB 605, 1010 2. Seperate permit required for commercial grease trap. AHJ 3. Grease Interceptor Exemption Form required. Emailed to applicant. AHJ 4. Specify materials for DWV FBCP 702 5. Specify materials for water distribution FBCP 605.3 6. Specify manufacturer, model, and design criteria for backflow protection at icemaker, bar refrigerator and espresso maker, if connected to potable water. FBCP 608 7. A-1 Restaurant with 139 occupants requires a minimum of 4 water closets, 2 lavatories, 1 drinking fountain and 1 service sink per FBCP 403.1 8. Show plumbing riser diagram FBC A 107.3.5
UD1 COMPLETE 08/21/2024 08/27/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
DSD HOLD 08/21/2024 08/22/2024
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Provide number of seat at bar Need to apply for liquor license.
GAS HOLD 08/21/2024 09/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. There was no existing gas in previous occupancy. remove all refernce to existing and provide a gas riser diagram showing piping sizes, materials and appliance btu ratings. 2. List gas subcontactor 3. All plan pages need to be separated Complete review was not completed. Additional comments may be generated after resubmittal
GAS HOLD 08/21/2024 09/05/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW. DID NOT SEE RISER IN PLANS. 1. REMOVE ALL REFERENCE TO EXISTING 2. SEPARATE ALL PLAN PAGES

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION - COMMERCIAL ¤60.00 03/27/2026
REINSPECTION - COMMERCIAL ¤60.00 03/25/2026
CONTRACTOR CHANGE ¤20.00 01/28/2026
CONTRACTOR CHANGE ¤20.00 12/03/2025
REINSPECTION - COMMERCIAL ¤60.00 09/12/2025
CONTRACTOR CHANGE ¤20.00 05/29/2025
SURCHARGE FS 533.721 ¤4.41 01/14/2025
SURCHARGE - FS 468.631 ¤6.62 01/14/2025
SITE PLAN 30 ¤30.00 01/14/2025
ADJUSTMENT 10% (¤49.00) 01/14/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 01/14/2025
INSPECTION COMMERCIAL ¤350.00 01/14/2025
PLAN REVIEW - COMMERCIAL ¤65.00 01/14/2025
Fees Total Due: ¤0.00 Total Paid: ¤722.03