Permit #2024080953
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00060-0090 |
| CONDITIONED SPACE: 2392 sqft |
| GARAGE: 550 sqft |
| OPENED PORCH (WITH ROOF) : 294 sqft |
| OPENED PORCH (WITH ROOF) : 69 sqft |
| Total Square Footage: 3305 sqft |
| Block: 00060 |
| Subdivision: - |
| Job Phone: 386-283-2035 |
| Location Address: 24 EMMONS LN |
| Type: DU - DUPLEX |
| Issue Date: 09/16/2024 |
| NOC: RECORDED |
| Applicant name: OLEG BELINSKIY |
| Owner: DIMITROVICH SVETLANA & EMELYANOV SEMEN W&H |
|
Address 282 FRANKLIN AVE CLIFFSIDE PARK, NJ 07010 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
FLORIDAS BEST BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE PALM COAST, FL 32164 |
CBC1264760 (Exp: 08/31/2026) | 386-283-2035 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/27/2025 | FINAL APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2490 need foam fire rate insulation on gang boxes in garage wall unit A | |||
| U-CROSS CONNECTION | 06/27/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cc | |||
| ROW - FINAL APRON (AFTER POUR) | 06/27/2025 | APPROVED | FSLADISH |
| Note: 6/27/25 AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. Inspector Notes from Inspection 9465 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth. | |||
| ROW - FINAL INSPECTION | 06/27/2025 | APPROVED | FSLADISH |
| Note: ALL REQUIRED ROAD REPAIRS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. ____________________________________________________________________________________________________________________- Inspector Notes from Inspection 9465 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth. | |||
| U -UTILITY RESIDENTIAL FINAL | 06/27/2025 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/11/2025 | APPROVED | FSLADISH |
| Note: 6/11/25 YOU NOW MEETING THE EDGE OF PAVEMENT EQUAL OR GREATER THAN PROPERTY LINE REQUIREMENT. I WILL DETERMINE ON THE FIELD SURVEY IF YOUR EMERSON DR FACING CULVERT WILL MEET OR FLOW REQUIREMENTS. 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT (27.35 EOP 26.10 PROPERTY LINE). THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMING OUT OF YOUR INVERT AT .26.35 GOING TO A 26.65 GOING TO A 26.30 AT THE PROPERTY LINE. THIS AREA WILL NOT HAVE POSITIVE DRAINAGE FLOW. Front Property Line Sec 300.01 C-3 Sec 300.01 C-3 = Elevation at the front property line shall match the edge of pavement elevation Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan. Inspector Notes from Inspection 9270 ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT. THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMONG OUT OF YOUR INVERT AT . | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/11/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/30/2025 | Disapproved - NO FEE | FSLADISH |
| Note: 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT (27.35 EOP 26.10 PROPERTY LINE). THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMING OUT OF YOUR INVERT AT .26.35 GOING TO A 26.65 GOING TO A 26.30 AT THE PROPERTY LINE. THIS AREA WILL NOT HAVE POSITIVE DRAINAGE FLOW. Front Property Line Sec 300.01 C-3 Sec 300.01 C-3 = Elevation at the front property line shall match the edge of pavement elevation Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan. Inspector Notes from Inspection 9270 ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT. THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMONG OUT OF YOUR INVERT AT . | |||
| ELECTRIC - EARLY POWER | 04/16/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 4/16/25 Okay to release e-mail to FPL 4/11/2025 - PREVIOUS INSPECTION NOTES Fix item before next inspection #1-NEC 110.27-SAFE OFF ALL WIRING , all gang boxes with cover have unsafe wire unit A and B , box for AH , box for Water heater , exterior light , kitchen area , PLease safe all wires unit A and B | |||
| ROW- PRE-APRON (PRE-POUR) | 04/16/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E | |||
| ELECTRIC - EARLY POWER | 04/11/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Fix item before next inspection #1-NEC 110.27-SAFE OFF ALL WIRING , all gang boxes with cover have unsafe wire unit A and B , box for AH , box for Water heater , exterior light , kitchen area , PLease safe all wires unit A and B | |||
| ROW- PRE-APRON (PRE-POUR) | 04/10/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E | |||
| ROW- PRE-APRON (PRE-POUR) | 04/07/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E | |||
| ROW- PRE-APRON (PRE-POUR) | 04/04/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E | |||
| GRAVITY SEWER TEST | 03/21/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET | |||
| SEWER TIE IN | 03/21/2025 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET | |||
| PEP TANK INSTALLATION REQUEST | 03/11/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 03/03/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: need foam fire rate insulation on gang boxes in garage wall unit A | |||
| ALL ROUGH | 02/25/2025 | APPROVED | MCONTRYMAN |
| Note: 2/18/2025 - PREVIOUS INSPECTION NOTES 2/18/25 Previous note not rectified #3-A and B units Back glass door missing FL approval number (PA number must be on door) In addition: 1. Energy calcs must be approved and stamped for each unit 2. Energy calcs need to be revised and approved to show 3040 windows installed in bathrooms in each unit 2/10/2025 - PREVIOUS INSPECTION NOTES #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain ) | |||
| ALL ROUGH | 02/18/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 2/18/25 Previous note not rectified #3-A and B units Back glass door missing FL approval number (PA number must be on door) In addition: 1. Energy calcs must be approved and stamped for each unit 2. Energy calcs need to be revised and approved to show 3040 windows installed in bathrooms in each unit 2/10/2025 - PREVIOUS INSPECTION NOTES #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain ) | |||
| ALL ROUGH | 02/10/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain ) | |||
| ALL ROUGH | 02/06/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 1/21/2025 - PREVIOUS INSPECTION NOTES Unit A #1- owners batroom fan missing seal at ceiling Unit A and B #2-FBCR P2605.1-PIPE SUPPORT ( need support on all PVC air vent pipes ) #3- glass door missinmg FL approval number #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow top and drain ) #5- missing doors front garage to leaving space | |||
| ALL ROUGH | 01/21/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Unit A #1- owners batroom fan missing seal at ceiling Unit A and B #2-FBCR P2605.1-PIPE SUPPORT ( need support on all PVC air vent pipes ) #3- glass door missinmg FL approval number #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow top and drain ) #5- missing doors front garage to leaving space | |||
| LATH/BRICK/ WATER BARRIER | 01/21/2025 | APPROVED | CVANSTRAHLEN |
| FIREWALL FINAL | 12/31/2024 | APPROVED | MCONTRYMAN |
| FIREWALL DRYWALL NAILING | 12/27/2024 | APPROVED | PKNAPIK |
| ROOF VALLEY & METAL | 12/26/2024 | APPROVED | PKNAPIK |
| Note: 12/20/2024 - PREVIOUS INSPECTION NOTES 12/20/2024 1. Not ready. Missing drip edge by front entry and back of the house. | |||
| ROOF VALLEY & METAL | 12/20/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 12/20/2024 1. Not ready. Missing drip edge by front entry and back of the house. | |||
| FIREWALL FRAMING | 12/20/2024 | APPROVED | PKNAPIK |
| Note: 12/17/2024 - PREVIOUS INSPECTION NOTES fire wall engineering is not by plan , 2x4 studs instal are not necesary for framing see plans for detail | |||
| WALL SHEATHING | 12/17/2024 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/17/2024 | APPROVED | CVANSTRAHLEN |
| FIREWALL FRAMING | 12/17/2024 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: fire wall engineering is not by plan , 2x4 studs instal are not necesary for framing see plans for detail | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/16/2024 | APPROVED | LSALYERDS |
| TIE BEAM / LINTEL | 12/09/2024 | APPROVED | MKRASKI |
| Note: | |||
| MONOLITHIC SLAB | 11/26/2024 | APPROVED - AS NOTED | PKNAPIK |
| Note: 11/26/2024 1. Please remove dirt from fundation on back before pouring. | |||
| ROW - DRAINAGE | 11/26/2024 | APPROVED | FSLADISH |
| Note: 11/21/2024 - PREVIOUS INSPECTION NOTES 11/21/24 SILT FENCE INSTALLED AS REQUIREDI N PREVIOUS INSPECTION NOTES. PORTA POTTY STILL IN COPC ROW, NEEDS TO BE MOVED ONTO YOUR SITE AS PREVIOUSLY NOTED. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 11/22/24 _______________________________________________________________________________________________________________________ 11/14/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| ROW - DRAINAGE | 11/21/2024 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 11/21/24 SILT FENCE INSTALLED AS REQUIREDI N PREVIOUS INSPECTION NOTES. PORTA POTTY STILL IN COPC ROW, NEEDS TO BE MOVED ONTO YOUR SITE AS PREVIOUSLY NOTED. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 11/22/24 _______________________________________________________________________________________________________________________ 11/14/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/20/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: WATER SERVICE NOT RAN YET | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 11/18/2024 | APPROVED | JMUNSON |
| ROW - DRAINAGE | 11/14/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| WATER METER INSTALLATION REQUEST | 10/23/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 02/19/2025 | 02/24/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/12/2025 | 02/14/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/10/2025 | 02/12/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. FL# 18583.1 the door you changed does not match with the manufacturer you listed. | |||
| BLD | COMPLETE | 01/22/2025 | 01/27/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/14/2025 | 01/14/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring in originals for processing | |||
| ZON | COMPLETE | 01/14/2025 | 01/14/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/13/2024 | 12/16/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/13/2024 | 12/13/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/12/2024 | 11/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/22/2024 | 10/28/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1.You already submitted this letter. Submit final letter and density reports. | |||
| SW1 | COMPLETE | 09/13/2024 | 09/13/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | COMPLETE | 09/13/2024 | 09/13/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/05/2024 | 09/05/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/05/2024 | 09/07/2024 |
| Note: Released By: JPI | |||
| MECH | COMPLETE | 09/05/2024 | 09/11/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/05/2024 | 09/05/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/05/2024 | 09/05/2024 |
| Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide driveway apron width at edge of pavement (both driveways) COPC Techinical Manual, Section 300.01 (A)(1)(C)(1) | |||
| BADMIN | COMPLETE | 08/22/2024 | 08/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/22/2024 | 08/22/2024 |
| Note: Held By: JPI 1. Based on an internet inquiry, the following product approval numbers appear to have recently expired, please cure. 10852 (Structural - Stud Plate Tie), 15638 (Structural - Truss Plates), 15228 (Composite Lumber). 107.2.4 | |||
| CUSVC | COMPLETE | 08/22/2024 | 08/26/2024 |
| Note: Released By: LUCY NABICO - - | |||
| ELEC | COMPLETE | 08/22/2024 | 08/29/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/22/2024 | 08/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/22/2024 | 08/27/2024 |
| LOCATE | COMPLETE | 08/22/2024 | 08/26/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/22/2024 | 08/28/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide return air out of bedrooms on duct layout | |||
| SW1 | COMPLETE | 08/22/2024 | 08/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/22/2024 | 08/22/2024 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plan shows 12'/ driveway must meet the minimum 16' width | |||
| SWALE | COMPLETE | 08/22/2024 | 10/24/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/10/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/10/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 04/04/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/10/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/05/2025 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 02/05/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/05/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/05/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/05/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/16/2024 |
| SW ENG PRE APRON | ¤30.00 | 09/16/2024 |
| IMPACT FEE TRANSPORTATION | ¤2,890.00 | 09/16/2024 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/16/2024 |
| SURCHARGE FS 533.721 | ¤14.73 | 09/16/2024 |
| SURCHARGE - FS 468.631 | ¤22.09 | 09/16/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/16/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/16/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/16/2024 |
| SEWER CREDIT | (¤1,700.00) | 09/16/2024 |
| SEWER INSPECTION | ¤25.00 | 09/16/2024 |
| SEWER CAPITAL FACILITY | ¤12,241.04 | 09/16/2024 |
| WATER CAPITAL FACILITY FEE | ¤8,702.28 | 09/16/2024 |
| SITE PLAN 30 | ¤30.00 | 09/16/2024 |
| WATER- TURN ON | ¤50.00 | 09/16/2024 |
| ADJUSTMENT 10% | (¤163.62) | 09/16/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/16/2024 |
| INSPECTION - RESIDENTIAL | ¤1,251.25 | 09/16/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤354.90 | 09/16/2024 |
| CONNECTION FEES | ¤2,374.52 | 09/16/2024 |
| FC IMPACT FEE EMS | ¤124.00 | 09/16/2024 |
| IMPACT FEE FIRE | ¤856.18 | 09/16/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 09/16/2024 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 09/16/2024 |
| IMPACT FEE PARKS | ¤3,600.18 | 09/16/2024 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 09/16/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤43,331.05 |