I want to search for...

Permit #2024080953

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00060-0090
CONDITIONED SPACE: 2392 sqft
GARAGE: 550 sqft
OPENED PORCH (WITH ROOF) : 294 sqft
OPENED PORCH (WITH ROOF) : 69 sqft
Total Square Footage: 3305 sqft
Block: 00060
Subdivision: -
Job Phone: 386-283-2035
Location Address: 24 EMMONS LN
Type: DU - DUPLEX
Issue Date: 09/16/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: DIMITROVICH SVETLANA & EMELYANOV SEMEN W&H

Address

282 FRANKLIN AVE

CLIFFSIDE PARK, NJ 07010

Lot: 0090
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/27/2025 FINAL APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2490 need foam fire rate insulation on gang boxes in garage wall unit A
U-CROSS CONNECTION 06/27/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
ROW - FINAL APRON (AFTER POUR) 06/27/2025 APPROVED FSLADISH
Note: 6/27/25 AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. Inspector Notes from Inspection 9465 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth.
ROW - FINAL INSPECTION 06/27/2025 APPROVED FSLADISH
Note: ALL REQUIRED ROAD REPAIRS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL MINIMUM COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. ____________________________________________________________________________________________________________________- Inspector Notes from Inspection 9465 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth.
U -UTILITY RESIDENTIAL FINAL 06/27/2025 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/11/2025 APPROVED FSLADISH
Note: 6/11/25 YOU NOW MEETING THE EDGE OF PAVEMENT EQUAL OR GREATER THAN PROPERTY LINE REQUIREMENT. I WILL DETERMINE ON THE FIELD SURVEY IF YOUR EMERSON DR FACING CULVERT WILL MEET OR FLOW REQUIREMENTS. 5/30/2025 - PREVIOUS INSPECTION NOTES 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT (27.35 EOP 26.10 PROPERTY LINE). THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMING OUT OF YOUR INVERT AT .26.35 GOING TO A 26.65 GOING TO A 26.30 AT THE PROPERTY LINE. THIS AREA WILL NOT HAVE POSITIVE DRAINAGE FLOW. Front Property Line Sec 300.01 C-3 Sec 300.01 C-3 = Elevation at the front property line shall match the edge of pavement elevation Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan. Inspector Notes from Inspection 9270 ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT. THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMONG OUT OF YOUR INVERT AT .
ROW FIELD SURVEY /GRADING CERTIFICATION 06/11/2025 APPROVED - AS NOTED FSLADISH
Note: 6/11/25 YOU WILL NEED TO MAKE ROADWAY EDGE REPAIRS IN AREAS OUTLINED IN PINK PAINT. YOU WILL NEED TO HAVE SITE MOWED IN ORDER FOR US TO ACCURATELY DETERMINE IF THE GRADE WILL MEET COPC FLOW REQUIREMENTS. ON THE LEFT SIDE YOU HAVE MATCHED GRADE AT PROPERTY LINE AT THE TIME OF THIS INSPECTION. AS A COURTESY I AM PASSING THIS FIELD SURVEY AS NOTED SO YOU MAY MOVE FORWARD WITH ADDITIONAL INSPECTIONS. YOU HAVE CORRECTIONS TO MAKE BEFORE ROW FINAL PASSAGE. INSPECTIONS/ ROW DAMAGE PREINSPECTION SEC 300,03 F1 V-21 1. SEC 300,03 F1 -A Preconstruction Inspection for road and swale damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested, the permittee will be responsible for all road and swale damage at the time of the final inspection LDC 35-76. (2)Excessive and untended growth of grass, weeds, brush, branches, and other overgrowth.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/30/2025 Disapproved - NO FEE FSLADISH
Note: 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT (27.35 EOP 26.10 PROPERTY LINE). THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMING OUT OF YOUR INVERT AT .26.35 GOING TO A 26.65 GOING TO A 26.30 AT THE PROPERTY LINE. THIS AREA WILL NOT HAVE POSITIVE DRAINAGE FLOW. Front Property Line Sec 300.01 C-3 Sec 300.01 C-3 = Elevation at the front property line shall match the edge of pavement elevation Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan. Inspector Notes from Inspection 9270 ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E 5/30/25 YOUR PROPERTY LINE AT THE INTERSECTION CORNER IS SHOWING OVER A FOOT LOWER THAN EDGE OF PAVEMENT. THIS PROPERTY LINE SHOT MUST BE EQUAL OR GREATER THAN EDGE OF PAVEMENT SHOT. YOU ARE SHOWING ON THE LEFT SIDE COMONG OUT OF YOUR INVERT AT .
ELECTRIC - EARLY POWER 04/16/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 4/16/25 Okay to release e-mail to FPL 4/11/2025 - PREVIOUS INSPECTION NOTES Fix item before next inspection #1-NEC 110.27-SAFE OFF ALL WIRING , all gang boxes with cover have unsafe wire unit A and B , box for AH , box for Water heater , exterior light , kitchen area , PLease safe all wires unit A and B
ROW- PRE-APRON (PRE-POUR) 04/16/2025 APPROVED - AS NOTED EMADISON
Note: ** 04/16/25 READY TO SET PAVERS ________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E
ELECTRIC - EARLY POWER 04/11/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Fix item before next inspection #1-NEC 110.27-SAFE OFF ALL WIRING , all gang boxes with cover have unsafe wire unit A and B , box for AH , box for Water heater , exterior light , kitchen area , PLease safe all wires unit A and B
ROW- PRE-APRON (PRE-POUR) 04/10/2025 APPROVED - AS NOTED TPOLACEK
Note: 04/10/25 TPOLACEK*** IF YOU ARE NOT PUTTING PAVERS ON THE MITERED ENDS PLEASE MAKE SURE YOU HAVE A MINIMUM OF 2" OF CONCRETE OVER THE MITERED OPEN END. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE T 4/7/2025 - PREVIOUS INSPECTION NOTES ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E
ROW- PRE-APRON (PRE-POUR) 04/07/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/07/25 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL UP TO FORM BOARDS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ON BOTH DRIVEWAYS ** ENSURE ON RIGHT SIDE DRIVEWAY YOU HAVE POSTIVE FALL AWAY FROM THE TRUCTURE FOR DRIVEWAY ___________________________________________________________________________________________________________________ 4/4/2025 - PREVIOUS INSPECTION NOTES BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E
ROW- PRE-APRON (PRE-POUR) 04/04/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: BOTH DRIVEWAY NEED TO HAVE THE 6"X6" FOOTERS FOR THE MITER ENDS AND #4 REBAR FOR UNDER THE CULVERT IN THE FOOTERS. PLEASE SEE DRAWING 300.E
GRAVITY SEWER TEST 03/21/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET
SEWER TIE IN 03/21/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 WATER SERVICE NOT RAN YET
PEP TANK INSTALLATION REQUEST 03/11/2025 APPROVED CBOWERMASTER
INSULATION 03/03/2025 APPROVED - AS NOTED CVANSTRAHLEN
Note: need foam fire rate insulation on gang boxes in garage wall unit A
ALL ROUGH 02/25/2025 APPROVED MCONTRYMAN
Note: 2/18/2025 - PREVIOUS INSPECTION NOTES 2/18/25 Previous note not rectified #3-A and B units Back glass door missing FL approval number (PA number must be on door) In addition: 1. Energy calcs must be approved and stamped for each unit 2. Energy calcs need to be revised and approved to show 3040 windows installed in bathrooms in each unit 2/10/2025 - PREVIOUS INSPECTION NOTES #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain )
ALL ROUGH 02/18/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 2/18/25 Previous note not rectified #3-A and B units Back glass door missing FL approval number (PA number must be on door) In addition: 1. Energy calcs must be approved and stamped for each unit 2. Energy calcs need to be revised and approved to show 3040 windows installed in bathrooms in each unit 2/10/2025 - PREVIOUS INSPECTION NOTES #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain )
ALL ROUGH 02/10/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: #3-A and B units Back glass door missinmg FL approval number #4-A and B units FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow over flow drain )
ALL ROUGH 02/06/2025 CANCELLED BY APPLICANT WEB
Note: 1/21/2025 - PREVIOUS INSPECTION NOTES Unit A #1- owners batroom fan missing seal at ceiling Unit A and B #2-FBCR P2605.1-PIPE SUPPORT ( need support on all PVC air vent pipes ) #3- glass door missinmg FL approval number #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow top and drain ) #5- missing doors front garage to leaving space
ALL ROUGH 01/21/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Unit A #1- owners batroom fan missing seal at ceiling Unit A and B #2-FBCR P2605.1-PIPE SUPPORT ( need support on all PVC air vent pipes ) #3- glass door missinmg FL approval number #4-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW ( water level is bellow top and drain ) #5- missing doors front garage to leaving space
LATH/BRICK/ WATER BARRIER 01/21/2025 APPROVED CVANSTRAHLEN
FIREWALL FINAL 12/31/2024 APPROVED MCONTRYMAN
FIREWALL DRYWALL NAILING 12/27/2024 APPROVED PKNAPIK
ROOF VALLEY & METAL 12/26/2024 APPROVED PKNAPIK
Note: 12/20/2024 - PREVIOUS INSPECTION NOTES 12/20/2024 1. Not ready. Missing drip edge by front entry and back of the house.
ROOF VALLEY & METAL 12/20/2024 Disapproved - NO FEE PKNAPIK
Note: 12/20/2024 1. Not ready. Missing drip edge by front entry and back of the house.
FIREWALL FRAMING 12/20/2024 APPROVED PKNAPIK
Note: 12/17/2024 - PREVIOUS INSPECTION NOTES fire wall engineering is not by plan , 2x4 studs instal are not necesary for framing see plans for detail
WALL SHEATHING 12/17/2024 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/17/2024 APPROVED CVANSTRAHLEN
FIREWALL FRAMING 12/17/2024 Disapproved - NO FEE CVANSTRAHLEN
Note: fire wall engineering is not by plan , 2x4 studs instal are not necesary for framing see plans for detail
FOUND SURVEY APPROVED (OFFICE) 12/16/2024 APPROVED LSALYERDS
TIE BEAM / LINTEL 12/09/2024 APPROVED MKRASKI
Note:
MONOLITHIC SLAB 11/26/2024 APPROVED - AS NOTED PKNAPIK
Note: 11/26/2024 1. Please remove dirt from fundation on back before pouring.
ROW - DRAINAGE 11/26/2024 APPROVED FSLADISH
Note: 11/21/2024 - PREVIOUS INSPECTION NOTES 11/21/24 SILT FENCE INSTALLED AS REQUIREDI N PREVIOUS INSPECTION NOTES. PORTA POTTY STILL IN COPC ROW, NEEDS TO BE MOVED ONTO YOUR SITE AS PREVIOUSLY NOTED. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 11/22/24 _______________________________________________________________________________________________________________________ 11/14/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
ROW - DRAINAGE 11/21/2024 Disapproved -FEE REQUIRED FSLADISH
Note: 11/21/24 SILT FENCE INSTALLED AS REQUIREDI N PREVIOUS INSPECTION NOTES. PORTA POTTY STILL IN COPC ROW, NEEDS TO BE MOVED ONTO YOUR SITE AS PREVIOUSLY NOTED. WILL BE BACK FOR COMPLIANCE REINSPECTION ON 11/22/24 _______________________________________________________________________________________________________________________ 11/14/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
PLUMBING 1ST ROUGH UNDERGROUND 11/20/2024 APPROVED - AS NOTED MGIBSON
Note: WATER SERVICE NOT RAN YET
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 11/18/2024 APPROVED JMUNSON
ROW - DRAINAGE 11/14/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO PUT UP A SILT FENCE AROUND ENTIRE PROPERTY LINE WERE THERE ARE ADAJACENT PROPERTYS 2) NEED TO MOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON TO YOUR PROPERTY. YOU WILL HAVE 7DAY TO CORRECT ALL ISSUES OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT.
WATER METER INSTALLATION REQUEST 10/23/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 02/19/2025 02/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/12/2025 02/14/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 02/10/2025 02/12/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. FL# 18583.1 the door you changed does not match with the manufacturer you listed.
BLD COMPLETE 01/22/2025 01/27/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 01/14/2025 01/14/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring in originals for processing
ZON COMPLETE 01/14/2025 01/14/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/13/2024 12/16/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 12/13/2024 12/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/12/2024 11/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 10/22/2024 10/28/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1.You already submitted this letter. Submit final letter and density reports.
SW1 COMPLETE 09/13/2024 09/13/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON COMPLETE 09/13/2024 09/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/05/2024 09/05/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/05/2024 09/07/2024
Note: Released By: JPI
MECH COMPLETE 09/05/2024 09/11/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/05/2024 09/05/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 09/05/2024 09/05/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM 1) Please provide driveway apron width at edge of pavement (both driveways) COPC Techinical Manual, Section 300.01 (A)(1)(C)(1)
BADMIN COMPLETE 08/22/2024 08/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 08/22/2024 08/22/2024
Note: Held By: JPI 1. Based on an internet inquiry, the following product approval numbers appear to have recently expired, please cure. 10852 (Structural - Stud Plate Tie), 15638 (Structural - Truss Plates), 15228 (Composite Lumber). 107.2.4
CUSVC COMPLETE 08/22/2024 08/26/2024
Note: Released By: LUCY NABICO - -
ELEC COMPLETE 08/22/2024 08/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/22/2024 08/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/22/2024 08/27/2024
LOCATE COMPLETE 08/22/2024 08/26/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 08/22/2024 08/28/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide return air out of bedrooms on duct layout
SW1 COMPLETE 08/22/2024 08/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 08/22/2024 08/22/2024
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plan shows 12'/ driveway must meet the minimum 16' width
SWALE COMPLETE 08/22/2024 10/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/10/2025
SW ENG REINSPECTION 30 ¤30.00 06/10/2025
SW ENG REINSPECTION 30 ¤30.00 04/04/2025
PLAN REVIEW - REVISION ¤32.50 03/10/2025
REINSPECTION RESIDENTIAL ¤40.00 03/10/2025
REINSPECTION RESIDENTIAL ¤40.00 03/10/2025
REINSPECTION RESIDENTIAL ¤40.00 02/05/2025
RECORDING FEE REIMBURSE DOC ¤44.00 02/05/2025
SW ENG - INSPECTION 20 ¤20.00 12/05/2024
SW ENG - INSPECTION 20 ¤20.00 12/05/2024
SW ENG - INSPECTION 20 ¤20.00 12/05/2024
SW ENG INSPECTION 80 ¤80.00 09/16/2024
SW ENG PRE APRON ¤30.00 09/16/2024
IMPACT FEE TRANSPORTATION ¤2,890.00 09/16/2024
WATER -IRRIGATION INSPECTION ¤50.00 09/16/2024
SURCHARGE FS 533.721 ¤14.73 09/16/2024
SURCHARGE - FS 468.631 ¤22.09 09/16/2024
SW ENG - FOUNDATION SURVEY ¤20.00 09/16/2024
SW ENG - REVIEW 20 ¤20.00 09/16/2024
SW ENG RES REVIEW 200 ¤200.00 09/16/2024
SEWER CREDIT (¤1,700.00) 09/16/2024
SEWER INSPECTION ¤25.00 09/16/2024
SEWER CAPITAL FACILITY ¤12,241.04 09/16/2024
WATER CAPITAL FACILITY FEE ¤8,702.28 09/16/2024
SITE PLAN 30 ¤30.00 09/16/2024
WATER- TURN ON ¤50.00 09/16/2024
ADJUSTMENT 10% (¤163.62) 09/16/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/16/2024
INSPECTION - RESIDENTIAL ¤1,251.25 09/16/2024
PLAN REVIEW - RESIDENTIAL ¤354.90 09/16/2024
CONNECTION FEES ¤2,374.52 09/16/2024
FC IMPACT FEE EMS ¤124.00 09/16/2024
IMPACT FEE FIRE ¤856.18 09/16/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 09/16/2024
FC IMPACT FEE LIBRARY ¤536.00 09/16/2024
IMPACT FEE PARKS ¤3,600.18 09/16/2024
IMPACT FEE SCHOOL ¤10,900.00 09/16/2024
Fees Total Due: ¤0.00 Total Paid: ¤43,331.05