I want to search for...

Permit #2024080974

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7023-00090-0190
Block: 00090
Subdivision: 7023 -
Job Phone: 386-387-1722
Location Address: 67 WHISPERING PINE DR
Type: DR - DRIVEWAY
Issue Date: 09/24/2024
NOC: Unknown
Applicant name: JONATHAN E SCHOFIELD
Owner: SEARS SARAH & THOMAS H&W

Address

67 WHISPERING PINE DR

PALM COAST, FL 32164

Lot: 0190
Contracted Stated Job Value: ¤2,400.00
Job Description: CONCRETE drive extension. L shape, 25ftx10ft area & 60ftx6ft area.
Type: CN

Contractor

STAY HARD CONCRETE PAVERS LLC
Status Location Address Phone
ACTIVE

123 WESTCHESTER LANE

PALM COAST, FL 32164

386-387-1722

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 12/27/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9270 09/25/24 TPOLACEK** SPOKE WITH TIM BAKER AND WE DETERMINED THAT THE PROPOSED AREA IS BEHIND THE ROW AND THE FORMED OUT AREA MEETS CITY STANDARDS. SPOKE WITH THE CONTRACTOR AND THEY WILL EMAIL A COPY TO ME AS WELL AS UPLOAD A NEW COPY TO THE PERMIT OF THE ORIGINAL SITE PLAN. I WILL APPROVE THE PRE POUR AS NOTED AND CONFIRM ON THE AFTER POUR THAT ALL DOCUMENTS ARE PRESENT. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/25/2024 - PREVIOUS INSPECTION NOTES 09/25/24 TPOLACEK** UPLOADED SITE PLAN IS BLANK. INSPECTOR NEEDS TO COMPARE A DETILED SITE PLAN WITH CONDITIONS IN FIELD IN ORDER TO APPROVE INSECTION. PLEASE UPLOAD A CORRECT SITE PLAN.
ROW - FINAL INSPECTION 12/27/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++Inspector Notes from Inspection 9270 09/25/24 TPOLACEK** SPOKE WITH TIM BAKER AND WE DETERMINED THAT THE PROPOSED AREA IS BEHIND THE ROW AND THE FORMED OUT AREA MEETS CITY STANDARDS. SPOKE WITH THE CONTRACTOR AND THEY WILL EMAIL A COPY TO ME AS WELL AS UPLOAD A NEW COPY TO THE PERMIT OF THE ORIGINAL SITE PLAN. I WILL APPROVE THE PRE POUR AS NOTED AND CONFIRM ON THE AFTER POUR THAT ALL DOCUMENTS ARE PRESENT. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/25/2024 - PREVIOUS INSPECTION NOTES 09/25/24 TPOLACEK** UPLOADED SITE PLAN IS BLANK. INSPECTOR NEEDS TO COMPARE A DETILED SITE PLAN WITH CONDITIONS IN FIELD IN ORDER TO APPROVE INSECTION. PLEASE UPLOAD A CORRECT SITE PLAN.
U -UTILITY RESIDENTIAL FINAL 12/27/2024 FINAL APPROVED BWRIGHT
ROW- PRE-APRON (PRE-POUR) 09/25/2024 Disapproved - NO FEE TPOLACEK
Note: 09/25/24 TPOLACEK** UPLOADED SITE PLAN IS BLANK. INSPECTOR NEEDS TO COMPARE A DETILED SITE PLAN WITH CONDITIONS IN FIELD IN ORDER TO APPROVE INSECTION. PLEASE UPLOAD A CORRECT SITE PLAN.
ROW- PRE-APRON (PRE-POUR) 09/25/2024 APPROVED - AS NOTED TPOLACEK
Note: 09/25/24 TPOLACEK** SPOKE WITH TIM BAKER AND WE DETERMINED THAT THE PROPOSED AREA IS BEHIND THE ROW AND THE FORMED OUT AREA MEETS CITY STANDARDS. SPOKE WITH THE CONTRACTOR AND THEY WILL EMAIL A COPY TO ME AS WELL AS UPLOAD A NEW COPY TO THE PERMIT OF THE ORIGINAL SITE PLAN. I WILL APPROVE THE PRE POUR AS NOTED AND CONFIRM ON THE AFTER POUR THAT ALL DOCUMENTS ARE PRESENT. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/25/2024 - PREVIOUS INSPECTION NOTES 09/25/24 TPOLACEK** UPLOADED SITE PLAN IS BLANK. INSPECTOR NEEDS TO COMPARE A DETILED SITE PLAN WITH CONDITIONS IN FIELD IN ORDER TO APPROVE INSECTION. PLEASE UPLOAD A CORRECT SITE PLAN.

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 08/22/2024 08/26/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 08/22/2024 08/28/2024
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 08/22/2024 08/22/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 09/24/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/24/2024
SW ENG INSPECTION 40 ¤40.00 09/24/2024
SW ENG PRE APRON ¤30.00 09/24/2024
SW ENG RES REVIEW 200 ¤200.00 09/24/2024
SITE PLAN 15 ¤15.00 09/24/2024
Fees Total Due: ¤0.00 Total Paid: ¤312.00