Permit #2024081002

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00690-0070
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00690
Subdivision: 7059 -
Job Phone: 386-283-2035
Location Address: 4 SLEIGH BELL PL
Type: DU - DUPLEX
Issue Date: 09/16/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: TARASOVA ANNA & ALEXANDER SHPERLING H&W

Address

2 CREEKSIDE COURT

PALM COAST, FL 32137

Lot: 0070
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 07/18/2025 APPROVED BWRIGHT
Note: 7/15/2025 - PREVIOUS INSPECTION NOTES No IRR. No CC
ROW - FINAL APRON (AFTER POUR) 07/15/2025 APPROVED FSLADISH
Note: 7/15/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
BLD - BUILDING FINAL 07/15/2025 FINAL APPROVED BTAYLOR
U-CROSS CONNECTION 07/15/2025 Disapproved - NO FEE BWRIGHT
Note: No IRR. No CC
ROW - FINAL INSPECTION 07/15/2025 APPROVED FSLADISH
Note: 7/15/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO REMOVE THE CONCRETE DEBRIS AND SOD TO GRADE THE RIGHT SIDE VACANT SWALE OUTLINED IN PINK PAINT BEFORE ROW FINAL PASSAGE.***
U -UTILITY RESIDENTIAL FINAL 07/15/2025 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/11/2025 APPROVED - AS NOTED FSLADISH
Note: 6/11/95 WALKED PROPERTY AND DETERMINED DRAINAGE IN FIELD WILL WORK AT THE TIME OF THIS INSPECTION. APPROVING THIS SURVEY AS NOTED. 6/3/2025 - PREVIOUS INSPECTION NOTES NOTE TO INSPECTOR 5/15/2025 MET WITH JASON FROM ROSS FOR GRADING OF THE LEFT SIDE OF PROPERTY. THERE WILL BE A COMMON SWALE DUE TO NEW CONSTRUCTION THE THE LEFT OF THIS PROPERTY. COMMON SWALE WILL NEED TO HAVE POSITIVE FLOW. 6/3/25 BASED ON THIS NOTE AND PRIOR CONVERSATION WITH GRADER, YOUR SURVEY IS INCORRECT PER THIS DISCUSSION. IT MATCHES YOUR SITE PLAN BUT A COMMON SWALE WAS DETERMINED TO BE NECCESSARY. YOUR SURVEY SHOWS AN INSIDE SWALE THIS IS SURVEY DOES NOT REFLECT THIS. PLEASE SEE PHOTO FOR REFERENCE.
ROW FIELD SURVEY /GRADING CERTIFICATION 06/11/2025 APPROVED FSLADISH
Note: 6/11/95 WALKED PROPERTY AND DETERMINED DRAINAGE IN FIELD WILL WORK AT THE TIME OF THIS INSPECTION. *** INSPECTORS NOTE. YOU WILL BE REQUIRED TO REMOVE THE COCRETE DEBRIS AND SOD TO GRADE THE RIGHT SIDE VACANT SWALE OUTLINED IN PINK PAINT BEFORE ROW FINAL PASSAGE.*** Inspector Notes from Inspection 9463 6/11/95 WALKED PROPERTY AND DETERMINED DRAINAGE IN FIELD WILL WORK AT THE TIME OF THIS INSPECTION. APPROVING THIS SURVEY AS NOTED. 6/3/2025 - PREVIOUS INSPECTION NOTES NOTE TO INSPECTOR 5/15/2025 MET WITH JASON FROM ROSS FOR GRADING OF THE LEFT SIDE OF PROPERTY. THERE WILL BE A COMMON SWALE DUE TO NEW CONSTRUCTION THE THE LEFT OF THIS PROPERTY. COMMON SWALE WILL NEED TO HAVE POSITIVE FLOW. 6/3/25 BASED ON THIS NOTE AND PRIOR CONVERSATION WITH GRADER, YOUR SURVEY IS INCORRECT PER THIS DISCUSSION. IT MATCHES YOUR SITE PLAN BUT A COMMON SWALE WAS DETERMINED TO BE NECCESSARY. YOUR SURVEY SHOWS AN INSIDE SWALE THIS IS SURVEY DOES NOT REFLECT THIS. PLEASE SEE PHOTO FOR REFERENCE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/03/2025 Disapproved - NO FEE FSLADISH
Note: NOTE TO INSPECTOR 5/15/2025 MET WITH JASON FROM ROSS FOR GRADING OF THE LEFT SIDE OF PROPERTY. THERE WILL BE A COMMON SWALE DUE TO NEW CONSTRUCTION THE THE LEFT OF THIS PROPERTY. COMMON SWALE WILL NEED TO HAVE POSITIVE FLOW. 6/3/25 BASED ON THIS NOTE AND PRIOR CONVERSATION WITH GRADER, YOUR SURVEY IS INCORRECT PER THIS DISCUSSION. IT MATCHES YOUR SITE PLAN BUT A COMMON SWALE WAS DETERMINED TO BE NECCESSARY. YOUR SURVEY SHOWS AN INSIDE SWALE THIS IS SURVEY DOES NOT REFLECT THIS. PLEASE SEE PHOTO FOR REFERENCE.
ROW- PROJECT STATUS 05/15/2025 Status Check PFLANAGAN
Note: MET WITH JASON FROM ROSS FOR GRADING OF THE LEFT SIDE OF PROPERTY. THERE WILL BE A COMMON SWALE DUE TO NEW CONSTRUCTION THE THE LEFT OF THIS PROPERTY. COMMON SWALE WILL NEED TO HAVE POSITIVE FLOW.
ROW- PRE-APRON (PRE-POUR) 04/21/2025 APPROVED PFLANAGAN
Note: READY FOR PAVERS ------------------------------------------------------------------------------- 4/14/2025 - PREVIOUS INSPECTION NOTES ** 04/14/25 APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
ELECTRIC - EARLY POWER 04/17/2025 APPROVED - AS NOTED BTAYLOR
Note: 4-17-25 1. Emailed FPL at 2:17.
ROW- PAVER RESTRAINTS 04/14/2025 APPROVED EMADISON
Note: ** 04/14//25 READY TO POUR PAVER RESTRAINTS AND APRON ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
ROW- PRE-APRON (PRE-POUR) 04/14/2025 PARTIALLY APPROVED EMADISON
Note: ** 04/14/25 APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
GRAVITY SEWER TEST 03/18/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 11/19/2024 - PREVIOUS INSPECTION NOTES MISSED INSPECTION,UNCOVER ALL WASTE AND VENT FBC[A] 110.1 PLUMBING CONCEALED. WATERSERVICE NOT RAN YET
SEWER TIE IN 03/18/2025 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 11/19/2024 - PREVIOUS INSPECTION NOTES MISSED INSPECTION,UNCOVER ALL WASTE AND VENT FBC[A] 110.1 PLUMBING CONCEALED. WATERSERVICE NOT RAN YET
PEP TANK INSTALLATION REQUEST 02/25/2025 APPROVED CBOWERMASTER
INSULATION 02/20/2025 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 2-14-25 1. Outlets on island need to be moved to the edges due to counter top over hang. Both units. 1/14/2025 - PREVIOUS INSPECTION NOTES 1-14-25 1. Missing garage door. 2. Bearing wall has been cut more than 60% in different locations. Repair will need to be done before moving forward. 3. Bearing wall studs have been cut more than 60% in different locations. Repair will need to be done before moving forward. 4. Electrical panel is not fire blocked at the top.
ALL ROUGH 02/14/2025 APPROVED - AS NOTED BTAYLOR
Note: 2-14-25 1. Outlets on island need to be moved to the edges due to counter top over hang. Both units. 1/14/2025 - PREVIOUS INSPECTION NOTES 1-14-25 1. Missing garage door. 2. Bearing wall has been cut more than 60% in different locations. Repair will need to be done before moving forward. 3. Bearing wall studs have been cut more than 60% in different locations. Repair will need to be done before moving forward. 4. Electrical panel is not fire blocked at the top.
LATH/BRICK/ WATER BARRIER 01/14/2025 APPROVED BTAYLOR
ALL ROUGH 01/14/2025 Disapproved - NO FEE BTAYLOR
Note: 1-14-25 1. Missing garage door. 2. Bearing wall has been cut more than 60% in different locations. Repair will need to be done before moving forward. 3. Bearing wall studs have been cut more than 60% in different locations. Repair will need to be done before moving forward. 4. Electrical panel is not fire blocked at the top.
FIREWALL FINAL 12/31/2024 APPROVED PKNAPIK
FIREWALL DRYWALL NAILING 12/27/2024 APPROVED FWILLIS
ROOF VALLEY & METAL 12/20/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/18/2024 APPROVED BTAYLOR
Note: 12/17/2024 - PREVIOUS INSPECTION NOTES 12/17/24 Approved to keep work going. Will check at next inspection 1. Missing fasteners for wall to block. Required tapcons for load bearing walls per plan
WALL SHEATHING 12/17/2024 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/17/2024 Disapproved - NO FEE MCONTRYMAN
Note: 12/17/24 Approved to keep work going. Will check at next inspection 1. Missing fasteners for wall to block. Required tapcons for load bearing walls per plan
FIREWALL FRAMING 12/17/2024 APPROVED MCONTRYMAN
FOUND SURVEY APPROVED (OFFICE) 12/16/2024 APPROVED LSALYERDS
TIE BEAM / LINTEL 12/05/2024 APPROVED BTAYLOR
MONOLITHIC SLAB 11/25/2024 APPROVED PKNAPIK
Note: 11/22/2024 - PREVIOUS INSPECTION NOTES 11-22-24 1. Need to have complete set of readable plans on site.
MONOLITHIC SLAB 11/22/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 11-22-24 1. Need to have complete set of readable plans on site.
PLUMBING 1ST ROUGH UNDERGROUND 11/20/2024 APPROVED - AS NOTED MGIBSON
Note: 11/19/2024 - PREVIOUS INSPECTION NOTES MISSED INSPECTION,UNCOVER ALL WASTE AND VENT FBC[A] 110.1 PLUMBING CONCEALED. WATERSERVICE NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 11/19/2024 Disapproved - NO FEE MGIBSON
Note: MISSED INSPECTION,UNCOVER ALL WASTE AND VENT FBC[A] 110.1 PLUMBING CONCEALED
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 11/18/2024 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 10/23/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 01/21/2025 01/27/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 COMPLETE 01/14/2025 01/15/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
ZON HOLD 01/14/2025 01/14/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please bring in originals for processing
ZON COMPLETE 01/14/2025 01/14/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/13/2024 12/16/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 12/13/2024 12/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/19/2024 11/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 11/12/2024 11/18/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss layout need shop drawing approval stamp by EOR
BLD COMPLETE 09/16/2024 09/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/05/2024 09/07/2024
Note: Released By: JPI
SWALE COMPLETE 08/23/2024 10/24/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BADMIN COMPLETE 08/22/2024 08/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 08/22/2024 08/29/2024
Note: Held By: JPI 1. Based on an internet inquiry, the following product approval numbers appear to have recently expired, please cure. 10852 (Structural - Stud Plate Tie), 15638 (Structural - Truss Plates), 15228 (Composite Lumber). 107.2.4
CUSVC COMPLETE 08/22/2024 08/26/2024
Note: Released By: LUCY NABICO - -
ELEC COMPLETE 08/22/2024 08/29/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/22/2024 08/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/22/2024 08/27/2024
LOCATE COMPLETE 08/22/2024 08/26/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 08/22/2024 08/28/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 08/22/2024 08/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/22/2024 08/23/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/11/2025
RECORDING FEE REIMBURSE DOC ¤44.00 02/11/2025
IMPACT FEE TRANSPORTATION ¤2,890.00 09/16/2024
WATER -IRRIGATION INSPECTION ¤50.00 09/16/2024
SURCHARGE FS 533.721 ¤14.79 09/16/2024
SURCHARGE - FS 468.631 ¤22.18 09/16/2024
SW ENG - FOUNDATION SURVEY ¤20.00 09/16/2024
SW ENG INSPECTION 80 ¤80.00 09/16/2024
SW ENG PRE APRON ¤30.00 09/16/2024
SW ENG - REVIEW 20 ¤20.00 09/16/2024
SW ENG RES REVIEW 200 ¤200.00 09/16/2024
SEWER CREDIT (¤2,932.00) 09/16/2024
SEWER INSPECTION ¤25.00 09/16/2024
SEWER CAPITAL FACILITY ¤12,241.04 09/16/2024
WATER CAPITAL FACILITY FEE ¤8,702.28 09/16/2024
SITE PLAN 30 ¤30.00 09/16/2024
CONNECTION FEES ¤2,374.52 09/16/2024
FC IMPACT FEE EMS ¤124.00 09/16/2024
IMPACT FEE FIRE ¤856.18 09/16/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 09/16/2024
FC IMPACT FEE LIBRARY ¤536.00 09/16/2024
IMPACT FEE PARKS ¤3,600.18 09/16/2024
IMPACT FEE SCHOOL ¤10,900.00 09/16/2024
WATER- TURN ON ¤50.00 09/16/2024
ADJUSTMENT 10% (¤164.32) 09/16/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/16/2024
INSPECTION - RESIDENTIAL ¤1,256.75 09/16/2024
PLAN REVIEW - RESIDENTIAL ¤356.46 09/16/2024
Fees Total Due: ¤0.00 Total Paid: ¤41,833.06