Permit #2024081175

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7015-00030-1870
Block: 00030
Subdivision: -
Job Phone: 386-627-8289
Location Address: 32 CHEYENNE CT
Type: DK - DOCK
NOC: RECORDED
Applicant name: ROBERT E WILLIAMS
Owner: BELL ANITA L TRUSTEE

Address

32 CHEYENNE CT

PALM COAST, FL 32137

Lot: 1870
Contracted Stated Job Value: ¤48,500.00
Job Description: Remove and replace multiple docks
Type: CN

Contractor

ELITE MARINE CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

14 UTILITY DR SUITE9

PALM COAST, FL 32137

SCC131152486 (Exp: 08/31/2026) 386-627-8289

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC

Review History

Department Status Date In Date Out
ZON HOLD 09/17/2024 09/17/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. As per LDC Chapter 4: 4.Floating docks. a.Floating docks shall not exceed a length of 20 feet as measured parallel to the canal frontage. The site plan still shows a 10'x25' floating dock. 2. The Engineered Drawings must accurately show ALL dimensions of proposed structures. The length of the longest one STILL is missing. 3. The way the new engineered drawing has been done is very unclear. It states 12'x25' boat slip - BUT it is not drawn as a boat slip. Also, the way it is drawn does not match the location and dimensions of what is drawn on the site plan. If there is space between the large dock and what you are calling the boat slip, that must be shown on the engineered drawing and it must be correctly shown where it is located in relation to the largest dock - to match the site plan. 3. Once all dimensions are corrected and what is being constructed is clarified on the engineered drawings, these must be mirrored exactly on site plan and overall dimensions and setbacks must total the overall frontage. 4. This property is deeded in a Trust. Please use the correct License Agreement for properties deeded in Trust and resubmit an electronic copy for staff review.
BLD COMPLETE 09/17/2024 09/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Change dimensions of boat slip from 12 ft X 25 ft to 10 ft by 25 ft to match dimensions on Site Plan 2. Change orientation of boat slip and 12 ft X 50 ft dock to match. Plan view from back yard looking into canal means the boat slip is on the right side of the 12 ft X 50 ft. dock. As shown the boat slip continues from the left side of dock. Reconcile plans to match Site Plan 3. Plans indicate dimension of boat slip but shows additional framing beyond the left end. That framing is not accounted for in the overall dimension of the boat slip or the 12 ft X 50 ft dock. Reconcile so all dimensions agree with Site Plan. 4. Boat slip indicates closed constructoin (stringers on all four sides). How is a boat to enter the boat slip?
BLD HOLD 08/28/2024 09/05/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2020 NEC ot the 2017
ZON HOLD 08/28/2024 08/28/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. As per LDC Chapter 4: Floating docks. a.Floating docks shall not exceed a length of 20 feet as measured parallel to the canal frontage. 2. The Engineered Drawings must accurately show ALL dimensions of proposed structures. The length of the longest one is missing. Also, the total projection (to include the pilings) of the floating dock must be shown. 3. Once the floating dock dimensions are corrected, these must be corrected on site plan and overall dimensions and setbacks must be corrected. 4. This property is deeded in a Trust. Please use the correct License Agreement for properties deeded in Trust and resubmit an electronic copy for staff review.
ZON CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RECORDING FEE REIMBURSE DOC ¤78.00
Fees Total Due: ¤78.00 Total Paid: ¤0.00