I want to search for...

Permit #2024090415

Permit Details

Status: COED

Total Square Footage: 30027 sqft
Block: 00000
Subdivision: 2334 - EVOLVE PALM COAST - SANDLAKE SUBDIVISION LOT 4
Job Phone: 304-694-7694
Location Address: 45 EVOLVE PKWY
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 09/26/2024
NOC: RECORDED
Applicant name: MATTHEW ADAM ROGERS
Owner: EVOLVE PALM COAST LLC

Address

2918-A MARTINSVILLE ROAD

GREENSBORO, NC 27408

Lot: 0040
Contracted Stated Job Value: ¤1,650,000.00
Job Description: BLDG 800 (22 UNITS)
Type: CN
Original Permit #: 2024030358

Contractor

EVOLVE CONSTRUCTION OF FL LLC
Status Location Address State License Number Phone
INACTIVE

2018A MARTINSVILLE RD

GREENSBORO, NC 27408

CGC1532932 (Exp: 08/31/2026) 304-694-7694

Sub Contractors

PAUL LEONARD RICHARDS
Status Location Address State License Number Phone Fax
ACTIVE

671 BUSINESS PARK BLVD

WINTER GARDEN, FL 34787

CAC057235 (Exp: 08/31/2026) 407-877-8090 407-877-8479
TRACEY LYNN HYMAN-MONTEE
Status Location Address State License Number Phone Fax
ACTIVE

75 STUMPFIELD ROAD

PENSACOLA, FL 32503

CFC1430978 (Exp: 08/31/2026) 850-477-0388 850-477-0381
MARK ASSELIN
Status Location Address State License Number Phone
ACTIVE

3508 LENOX AVE

JACKSONVILLE, FL 32254

EC13009251 (Exp: 08/31/2026) 904-726-7966
JOSHUA DAVID CADILLAC
Status Location Address State License Number Phone
CANCEL

3264 S UNIVERSITY DRIVE

MIRMAR, FL 33025

CCC1333894 (Exp: 08/31/2026) 954-333-8697

Inspection History

Type Request Date Result Inspector
EXTERIOR ARCHITECTURAL FEATURES 11/20/2025 APPROVED RPICATAGI
BUILDING FINAL 11/14/2025 APPROVED KSANDOE
U - UTILITY COMMERCIAL FINAL 11/14/2025 FINAL APPROVED BWRIGHT
FIRE FINAL 11/13/2025 APPROVED JMUNSON
FIRE FINAL 11/12/2025 CANCELLED BY APPLICANT WEB
U -UTILITY RESIDENTIAL FINAL 10/29/2025 FINAL APPROVED BWRIGHT
HORIZONTAL ASSEMB FINAL 10/28/2025 APPROVED FWILLIS
FRAMING 10/28/2025 APPROVED FWILLIS
Note: 3/17/2025 - PREVIOUS INSPECTION NOTES
ELECTRIC FINAL 10/24/2025 FINAL APPROVED MKRASKI
ELECTRIC FINAL 10/23/2025 Disapproved - NO FEE MKRASKI
Note: *** NOTES ADDED BY MKRASKI 10/23/2025 12:58:10 PM *** ***Be sure panel and schdule matches the approved plans, plans show 2 house panels, only one house panel per building. Please ensure breaker sizes match as well as circuit numbers per plans*** 10/23/25 1. House panel needs to be labeled properly NEC 408.4 10/21/25 1. House panel needs to be labeled properly 2. Balcony GFCI not working in 207 3. Dryer GFCI breaker wont hold in 105 4. Breaker lock required for hard wired range in 105 5. Master bathroom echaust fan not working in 106 6. Breaker lock required for hard wired range in 101 8/21/25 Emailed FPL for power release @ 12:45pm 7/23/25 Power to House panel only, will need to call back in when ready for power to units, Main breakers will need to be locked out at all times. Will need to revise plan by final on service grounding diagram and change from 100A disconnects to 125A disconnects.
ELECTRIC FINAL 10/21/2025 Disapproved - NO FEE MKRASKI
Note: 10/21/25 1. House panel needs to be labeled properly 2. Balcony GFCI not working in 207 3. Dryer GFCI breaker wont hold in 105 4. Breaker lock required for hard wired range in 105 5. Master bathroom echaust fan not working in 106 6. Breaker lock required for hard wired range in 101 8/21/25 Emailed FPL for power release @ 12:45pm 7/23/25 Power to House panel only, will need to call back in when ready for power to units, Main breakers will need to be locked out at all times. Will need to revise plan by final on service grounding diagram and change from 100A disconnects to 125A disconnects.
PLUMBING FINAL 10/09/2025 APPROVED MGIBSON
HORIZONTAL ASSEMB DRYWALL 10/03/2025 APPROVED FWILLIS
Note: 10/3/25 - DRYWALL INSPECTION COMPLETE FOR BUILDING. 6/10/2025 - PREVIOUS INSPECTION NOTES 6/10/25 - "B" SIDE ONLY 6/5/2025 - PREVIOUS INSPECTION NOTES 3rd FLOOR BREEZEWAY
HORIZONTAL ASSEMB FRAMING 10/03/2025 APPROVED FWILLIS
Note: *** NOTES ADDED BY FWILLIS 10/3/2025 12:43:01 PM *** INSPECTION COMPLETE FOR THIS BUILDING 6/11/2025 - PREVIOUS INSPECTION NOTES
HORIZONTAL ASSEMB PENETRATIONS 10/02/2025 APPROVED FWILLIS
ROOF SHEATHING / BRACE / TIE DOWN 10/02/2025 CANCELLED BY INSPECTOR FWILLIS
Note: THIRD PARTY INSPECTION
U-CROSS CONNECTION 10/02/2025 APPROVED BWRIGHT
STOREFRONT 10/02/2025 CANCELLED BY INSPECTOR FWILLIS
U - SEWER TIE IN 10/02/2025 APPROVED MGIBSON
PLUMBING 2ND ROUGH 10/02/2025 APPROVED MGIBSON
Note: 5/22/2025 - PREVIOUS INSPECTION NOTES NAIL PLATES ANDFIRE CAULK NEED, PLUMBER WALKED ALL UNITS AN IS AWARE
HVAC FINAL 09/26/2025 FINAL APPROVED CPISCITELLI
Note:
HVAC FINAL 09/25/2025 PARTIALLY APPROVED CPISCITELLI
Note: 1st floor inspected
INSULATION 09/16/2025 APPROVED FWILLIS
U - SEWER TIE IN 08/28/2025 CANCELLED BY APPLICANT WEB
BLD - SEWER TIE IN 08/28/2025 APPROVED MGIBSON
ELECTRIC - EARLY POWER 08/21/2025 APPROVED - AS NOTED MKRASKI
Note: 8/21/25 Emailed FPL for power release @ 12:45pm 7/23/25 Power to House panel only, will need to call back in when ready for power to units, Main breakers will need to be locked out at all times. Will need to revise plan by final on service grounding diagram and change from 100A disconnects to 125A disconnects.
STOREFRONT 07/30/2025 CANCELLED BY INSPECTOR KSANDOE
ELECTRIC - EARLY POWER 07/23/2025 PARTIALLY APPROVED RMARTIN
Note: Power to House panel only, will need to call back in when ready for power to units, Main breakers will need to be locked out at all times. Will need to revise plan by final on service grounding diagram and change from 100A disconnects to 125A disconnects.
FIREWALL FRAMING 07/14/2025 APPROVED FWILLIS
FIREWALL FINAL 07/14/2025 APPROVED FWILLIS
FIREWALL DRYWALL NAILING 06/20/2025 APPROVED FWILLIS
Note: GARAGE AREAS FIRST FLOOR. 6/17/2025 - PREVIOUS INSPECTION NOTES
FIREWALL DRYWALL NAILING 06/17/2025 PARTIALLY APPROVED FWILLIS
HORIZONTAL ASSEMB FRAMING 06/11/2025 PARTIALLY APPROVED FWILLIS
HORIZONTAL ASSEMB DRYWALL 06/10/2025 PARTIALLY APPROVED FWILLIS
Note: 6/10/25 - "B" SIDE ONLY 6/5/2025 - PREVIOUS INSPECTION NOTES 3rd FLOOR BREEZEWAY
INSULATION 06/09/2025 APPROVED FWILLIS
Note: 6/9/25 - INSPECTED "A" SIDE OF BUILDING. 6/6/2025 - PREVIOUS INSPECTION NOTES "B Side" OF BUILDING 800 (right side as your facing building) "A SIDE" NOT READY. WORKERS (ladies) WERE FINISHING UP B SIDE AT THE TIME OF MY VISIT.
INSULATION 06/06/2025 PARTIALLY APPROVED FWILLIS
Note: "B Side" OF BUILDING 800 (right side as your facing building) "A SIDE" NOT READY. WORKERS (ladies) WERE FINISHING UP B SIDE AT THE TIME OF MY VISIT.
HORIZONTAL ASSEMB DRYWALL 06/05/2025 PARTIALLY APPROVED FWILLIS
Note: 3rd FLOOR BREEZEWAY
WINDOW NAILING 06/05/2025 APPROVED FWILLIS
Note: 3/17/2025 - PREVIOUS INSPECTION NOTES Includes All Windows, Three Floors and Doors only on the First Floor.
FIREWALL PENETRATIONS 05/29/2025 APPROVED FWILLIS
Note: BATHROOMS CORNER UNIT BEHIND THE TUB.
FIREWALL PENETRATIONS 05/28/2025 APPROVED FWILLIS
LATH/BRICK/WATER BARRIER 05/27/2025 APPROVED FWILLIS
PLUMBING 2ND ROUGH 05/22/2025 PARTIALLY APPROVED MGIBSON
Note: NAIL PLATES ANDFIRE CAULK NEED, PLUMBER WALKED ALL UNITS AN IS AWARE
HORIZONTAL ASSEMB FRAMING 05/12/2025 APPROVED FWILLIS
Note: BREEZEWAY AND THIRD FLOOR
HVAC ROUGH 05/07/2025 APPROVED CPISCITELLI
Note: 4/28/2025 - PREVIOUS INSPECTION NOTES seams for fresh air and exhaust
ELECTRIC 2ND ROUGH 05/01/2025 APPROVED MKRASKI
HVAC ROUGH 04/28/2025 PARTIALLY APPROVED CPISCITELLI
Note: seams for fresh air and exhaust
FIREWALL PENETRATIONS 04/28/2025 APPROVED FWILLIS
Note: Building #800 Bathroom on the end three floors both sides. Checked Cables and any Penertrations.
FIREWALL DRYWALL NAILING 03/27/2025 APPROVED FWILLIS
Note: SECOND LAYER
LATH/BRICK/WATER BARRIER 03/26/2025 APPROVED FWILLIS
Note: 3/26/25 - BREEZEWAY 3/18/2025 - PREVIOUS INSPECTION NOTES NOT READY FOR INSPECTION. NOT COMPLETE.
FIREWALL DRYWALL NAILING 03/26/2025 APPROVED FWILLIS
Note: BREEZEWAY
FOUND SURVEY APPROVED (OFFICE) 03/25/2025 APPROVED DLEAP
LATH/BRICK/WATER BARRIER 03/18/2025 Disapproved - NO FEE FWILLIS
Note: NOT READY FOR INSPECTION. NOT COMPLETE.
WINDOW NAILING 03/17/2025 PARTIALLY APPROVED FWILLIS
Note: Includes All Windows, Three Floors and Doors only on the First Floor.
FRAMING 03/17/2025 CANCELLED BY APPLICANT FWILLIS

Review History

Department Status Date In Date Out
BLD COMPLETE 10/03/2025 10/15/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/02/2025 06/18/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLENG COMPLETE 03/25/2025 03/25/2025
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 03/12/2025 03/13/2025
Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Label plan "FOUNDATION SURVEY" and not SPECIFIC PURPOSE SURVEY. 2. Highlight foundation for specific foundation being permitted for in this permit application.
BLD CANCEL 09/26/2024 09/26/2024
PLFM INFORMATION 09/13/2024 09/16/2024
Note: Marked INFORMATION By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Vertical construction is not authorized until floodplain requirements have been met.
GAS CANCEL 09/10/2024 09/13/2024
MECH COMPLETE 09/10/2024 09/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
UD1 COMPLETE 09/10/2024 09/12/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
PLUM COMPLETE 09/10/2024 09/13/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ARCHR COMPLETE 09/10/2024 09/16/2024
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD COMPLETE 09/10/2024 09/13/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
DSD COMPLETE 09/10/2024 09/12/2024
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC COMPLETE 09/10/2024 09/13/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 09/10/2024 09/13/2024
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
IMPACT FEE PARKS ¤39,621.78 05/23/2025
IMPACT FEE TRANSPORTATION ¤43,164.00 05/23/2025
IMPACT FEE FIRE ¤9,417.98 04/02/2025
FC IMPACT FEE LAW ENFORCEMENT ¤2,442.00 09/26/2024
FC IMPACT FEE LIBRARY ¤3,058.00 09/26/2024
IMPACT FEE SCHOOL ¤29,920.00 09/26/2024
ADJUSTMENT 10% (¤1,203.75) 09/26/2024
ADMINISTRATIVE - COMMERCIAL ¤75.00 09/26/2024
INSPECTION COMMERCIAL ¤11,550.00 09/26/2024
INSPECTION - FIRE COMMERCIAL ¤412.50 09/26/2024
FC IMPACT FEE EMS ¤704.00 09/26/2024
SURCHARGE FS 533.721 ¤108.34 09/26/2024
SURCHARGE - FS 468.631 ¤162.51 09/26/2024
SITE PLAN 30 ¤30.00 09/26/2024
Fees Total Due: ¤0.00 Total Paid: ¤139,462.36