I want to search for...
Permit #2024090452
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7027-00100-0100 |
| Block: 00100 |
| Subdivision: 7027 - |
| Job Phone: 386-597-3728 |
| Location Address: 28 WOODSTONE LN |
| Type: ME - MECHANICAL |
| Issue Date: 09/11/2024 |
| NOC: Unknown |
| Applicant name: ROBERT BRUCE DAVENPORT |
| Owner: JAROSZ CALVIN & JULIE H&W |
|
Address 28 WOODSTONE LANE PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤6,500.00 |
| Job Description: HVAC LIKE FOR LIKE TONNAGE |
| Type: CN |
Contractor
COMFORT AIRE LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 PALM COAST PKWY NE 607-210 PALM COAST, FL 32137 |
CAC1819719 (Exp: 08/31/2026) | 386-401-9222 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 12/26/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 12/26/24 1. Truss's have been screwed into for all thread to hang AHU in attic, A engineered truss repair letter is required and needs to be uploaded and approved by Building Dept. before calling in for re-inspection 10/3/24 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU Entire unit 3. Plywood can not be used as a stand under AHU and is molded 9/16/2024 - PREVIOUS INSPECTION NOTES 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU 3. Romex requires proper connector going into AHU disconnect NEC 334.15 4. NOTICE TO OWNER UNIT IN ATTIC POSTED AT PANEL FBCR EC R 403.3.6 5. High voltage romex has been stripped back going in AHU disconnect exposin wiring, Sheathing must extend 1/4'' into disconnect NEC 334 | |||
| FINAL - BUILDING MISC | 12/26/2024 | CANCELLED BY INSPECTOR | MKRASKI |
| HVAC FINAL | 10/03/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 10/3/24 1. Ducts not connected to AHU properly FBCR M1601.4.1 (appears that the wrong size elbow was use) Must be properly sealed and connected per manufacter specs 2. AHU pan in attic must be 3'' larger then AHU Entire unit FBC M1411.3.1 3. Plywood can not be used as a stand under AHU and is molded FBC M1411.3.1.2 9/16/2024 - PREVIOUS INSPECTION NOTES 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU 3. Romex requires proper connector going into AHU disconnect NEC 334.15 4. NOTICE TO OWNER UNIT IN ATTIC POSTED AT PANEL FBCR EC R 403.3.6 5. High voltage romex has been stripped back going in AHU disconnect exposin wiring, Sheathing must extend 1/4'' into disconnect NEC 334 | |||
| HVAC FINAL | 09/16/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU 3. Romex requires proper connector going into AHU disconnect NEC 334.15 4. NOTICE TO OWNER UNIT IN ATTIC POSTED AT PANEL FBCR EC R 403.3.6 5. High voltage romex has been stripped back going in AHU disconnect exposin wiring, Sheathing must extend 1/4'' into disconnect NEC 334 | |||
| HVAC FINAL | |||
| Note: 12/26/2024 - PREVIOUS INSPECTION NOTES 12/26/24 1. Truss's have been screwed into for all thread to hang AHU in attic, A engineered truss repair letter is required and needs to be uploaded and approved by Building Dept. before calling in for re-inspection 10/3/24 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU Entire unit 3. Plywood can not be used as a stand under AHU and is molded 9/16/2024 - PREVIOUS INSPECTION NOTES 1. Ducts not connected to AHU properly FBCR M1601.4.1 2. AHU pan in attic must be 3'' larger then AHU 3. Romex requires proper connector going into AHU disconnect NEC 334.15 4. NOTICE TO OWNER UNIT IN ATTIC POSTED AT PANEL FBCR EC R 403.3.6 5. High voltage romex has been stripped back going in AHU disconnect exposin wiring, Sheathing must extend 1/4'' into disconnect NEC 334 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/01/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/11/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/11/2024 |
| ADJUSTMENT 10% | (¤9.00) | 09/11/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/11/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 09/11/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |