I want to search for...
Permit #2024090625
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00480-0280 |
| Total Square Footage: 1604 sqft |
| Block: 00480 |
| Subdivision: 7026 - |
| Job Phone: 904-813-3820 |
| Location Address: 36 PIERCE LN |
| Type: ME - MECHANICAL |
| Issue Date: 10/02/2024 |
| NOC: Unknown |
| Applicant name: GARY JAMES HOLLAND |
| Owner: SCHORNER KAROLA |
|
Address 36 PIERCE LANE PALM COAST, FL 32164 |
| Lot: 0280 |
| Contracted Stated Job Value: ¤6,450.00 |
| Job Description: replacement of existing equipment |
| Type: CN |
Contractor
HOLLAND A/C & HEATING SERVICES INC
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
5000-18 HWY 17 FLEMING ISLAND, FL 32003 |
#52 FLEMING ISLAND, FL 32003 |
CAC1817261 (Exp: 08/31/2026) | 904-813-3820 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 12/09/2024 | FINAL APPROVED | RSIMS |
| Note: 10/15/2024 - PREVIOUS INSPECTION NOTES 10/15/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). One of the locking port caps is not locked. FBC-M1411.8 2). Liquid-tite requires additional straps at 12" max from connections to box and unit. NEC-350.30(A) | |||
| HVAC FINAL | 10/15/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/15/2024 12:12:53 PM *** 10/15/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). One of the locking port caps is not locked. FBC-M1411.8 2). Liquid-tite requires additional straps at 12" max from connections to box and unit. NEC-350.30(A) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/15/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/02/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/02/2024 |
| ADJUSTMENT 10% | (¤9.00) | 10/02/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/02/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 10/02/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |