Permit #2024090912

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7035-00050-0140
Block: 00050
Subdivision: -
Job Phone: 786-512-4421
Location Address: 4 BIRD OF PARADISE DR
Type: DR - DRIVEWAY
Issue Date: 10/01/2024
NOC: Unknown
Applicant name: ABEL MENENDEZ
Owner: LEON MANEUL A MATALLANA & DYANA MATALLANA JTWROS

Address

4 BIRD OF PARADISE DRIVE

PALM COAST, FL 32137

Lot: 0140
Contracted Stated Job Value: ¤4,500.00
Job Description: 18x36 Concrete drive way extension
Type: CN

Contractor

ROYAL TILE & PAVERS INC
Status Location Address Phone
ACTIVE

69 FLEETWOOD DR

PALM COAST, FL 32137

786-512-4421

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 09/29/2025 Disapproved - NO FEE EMADISON
Note: ** 09/29/25 nOT NOTED IN PREVIOUS INSPECTION THE BUILDER IS REQUIRED TO MAKE A HOT ASPHALT ROAD REPAIR ACROSS THE APRON OF THE DRIVEWAY ROAD REPAIR IS TO BE A MINIMUM OF 12 INCHES WIDE BY THE LENGTH OF THE APRON ** I AM NOT FEEING THIS INSPECTION DUE TO PREVIOUS INSPECTION NOT NOTING IT HOWEVER IF YOU HAVE NOT CORRECTED AT THE TIME OF THE NEXT SCHEDULED INSPECTION A FEE WILL BE IMPOSED ____________________________________________________________________________________________________________________ New inspection due to canceled inspection 4/8/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT. 2) NEED TO REPAIR ALL BARE AREAS AND WASHOUTS WITH DIRT AND SOD . 3) NEED TO A SAW CUT IN CONCRETE OVER CULVERT PIPE. SEC 300,03 F4 V-21-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded. SEE DRAWING 300.E
ROW - FINAL INSPECTION 04/10/2025 CANCELLED BY APPLICANT WEB
Note: 4/8/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT. 2) NEED TO REPAIR ALL BARE AREAS AND WASHOUTS WITH DIRT AND SOD . 3) NEED TO A SAW CUT IN CONCRETE OVER CULVERT PIPE. SEC 300,03 F4 V-21-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded. SEE DRAWING 300.E
U -UTILITY RESIDENTIAL FINAL 04/08/2025 FINAL APPROVED DHANEY
ROW - FINAL INSPECTION 04/08/2025 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT. 2) NEED TO REPAIR ALL BARE AREAS AND WASHOUTS WITH DIRT AND SOD . 3) NEED TO A SAW CUT IN CONCRETE OVER CULVERT PIPE. SEC 300,03 F4 V-21-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded. SEE DRAWING 300.E
ROW- PRE-APRON (PRE-POUR) 10/30/2024 APPROVED PFLANAGAN
Note: DO NOT CHANGE ANYTHING AFTER THIS INSPECTION IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------------------- 10/29/2024 - PREVIOUS INSPECTION NOTES DROVE BY AND SEEN THAT ROYAL TILE WAS FILLING IN THE ENTIRE DRIVEWAY WITH BASE AND NOW THE BASE IS NOT TO CITY'S STANDARDS DO TO NOT HAVE THE MINIMUM AMOUNT OF CONCRETE. NEED TO HAVE ANOTHER INSPECTION DONE BEFORE POURING. IF YOU POUR THE DRIVEWAY WITH OUT THIS INSPECTION YOU WILL BE PULLING THE DRIVEWAY PER GABE, PARREN, ED.
ROW- PRE-APRON (PRE-POUR) 10/29/2024 Disapproved - NO FEE PFLANAGAN
Note: DROVE BY AND SEEN THAT ROYAL TILE WAS FILLING IN THE ENTIRE DRIVEWAY WITH BASE AND NOW THE BASE IS NOT TO CITY'S STANDARDS DO TO NOT HAVE THE MINIMUM AMOUNT OF CONCRETE. NEED TO HAVE ANOTHER INSPECTION DONE BEFORE POURING. IF YOU POUR THE DRIVEWAY WITH OUT THIS INSPECTION YOU WILL BE PULLING THE DRIVEWAY PER GABE, PARREN, ED.
ROW- PRE-APRON (PRE-POUR) 10/25/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ----------------------------------------------------------------------------- 10/21/2024 - PREVIOUS INSPECTION NOTES 1) SOIL TO SOFT NEED TO COMPACT SOIL TO CITY STANDARDS. 2) THE CULVERT CAN ONLY BE BURIED HALF WAY. 3) THE SWALE PLAN DETAIL IS CHANGING THE INVERT NOE IS GOING TO BE AT A 26.80 SO PIPE IS NOT LOWER THEN CATCH BASIN TO THE RIGHT.
ROW- PRE-APRON (PRE-POUR) 10/21/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) SOIL TO SOFT NEED TO COMPACT SOIL TO CITY STANDARDS. 2) THE CULVERT CAN ONLY BE BURIED HALF WAY. 3) THE SWALE PLAN DETAIL IS CHANGING THE INVERT NOE IS GOING TO BE AT A 26.80 SO PIPE IS NOT LOWER THEN CATCH BASIN TO THE RIGHT.
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
Note: 9/29/2025 - PREVIOUS INSPECTION NOTES ** 09/29/25 nOT NOTED IN PREVIOUS INSPECTION THE BUILDER IS REQUIRED TO MAKE A HOT ASPHALT ROAD REPAIR ACROSS THE APRON OF THE DRIVEWAY ROAD REPAIR IS TO BE A MINIMUM OF 12 INCHES WIDE BY THE LENGTH OF THE APRON ** I AM NOT FEEING THIS INSPECTION DUE TO PREVIOUS INSPECTION NOT NOTING IT HOWEVER IF YOU HAVE NOT CORRECTED AT THE TIME OF THE NEXT SCHEDULED INSPECTION A FEE WILL BE IMPOSED ____________________________________________________________________________________________________________________ New inspection due to canceled inspection 4/8/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT. 2) NEED TO REPAIR ALL BARE AREAS AND WASHOUTS WITH DIRT AND SOD . 3) NEED TO A SAW CUT IN CONCRETE OVER CULVERT PIPE. SEC 300,03 F4 V-21-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded. SEE DRAWING 300.E

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/03/2024 10/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 10/03/2024 10/03/2024
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 10/03/2024 10/03/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 10/01/2024 10/01/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/01/2024 10/01/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 10/01/2024 10/01/2024
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/24/2024 09/30/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 09/24/2024 09/30/2024
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON HOLD 09/24/2024 09/25/2024
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Because of the reduced clarity of the numbers on the site plan, please indicate the total width of the proposed driveway - noting that it can only be 36' wide.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 10/01/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/01/2024
SW ENG INSPECTION 40 ¤40.00 10/01/2024
SW ENG PRE APRON ¤30.00 10/01/2024
SW ENG RES REVIEW 200 ¤200.00 10/01/2024
SITE PLAN 15 ¤15.00 10/01/2024
SW ENG REINSPECTION 20 ¤20.00
Fees Total Due: ¤20.00 Total Paid: ¤312.00