Permit #2024091017

Permit Details

Status: COED

Parcel Id: 07-11-31-7058-00280-0160
Total Square Footage: 0 sqft
Block: 00280
Subdivision: 2215 - SECTION 58-SEMINOLE PARK
Job Phone: (386) 547-0409
Location Address: 13 SERENADE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/04/2024
NOC: RECORDED
Applicant name: JEFFREY G SPRAGUE
Owner: INTERCOASTAL CONSTRUCTION

Address

33 SENECA PATH

PALM COAST, FL 32164

Lot: 0160
Contracted Stated Job Value: ¤10,000.00
Job Description: REF: 2023021245 - SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2023021245

Contractor

JGS DESIGN ASSOCIATES, LLC
Status Location Address State License Number Phone
INACTIVE

8 INDIAN MOUND CT

FLAGLER BEACH, FL 32136

CBC1260630 (Exp: 08/31/2026) 386-585-0958

Sub Contractors

GREGORY ALLEN HENRY
Status Location Address State License Number Phone
ACTIVE

1332 SUNSET BLVD

DAYTONA BEACH, FL 32117

EC13009193 (Exp: 08/31/2026) 386-679-6908
BRETT FORREST L'AMIE
Status Location Address State License Number
INACTIVE

919 VALENCIA ROAD

SOUTH DAYTONA, FL 32119

CFC1428647 (Exp: 08/31/2026)
MICHAEL A TORRES JR
Status Location Address State License Number Phone
INACTIVE

846 JASMINE AVE

HOLLY HILL , FL 32117

CAC1815003 (Exp: 08/31/2026) 386-212-9442
JEFFREY G SPRAGUE
Status Location Address State License Number Phone
INACTIVE

8 INDIAN MOUND CT

FLAGLER BEACH, FL 32136

CBC1260630 (Exp: 08/31/2026) 386-585-0958

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/30/2025 FINAL APPROVED BTAYLOR
Note: 1/21/2025 - PREVIOUS INSPECTION NOTES 1-21-25 1. Energy cals on site do not match equiptment that is installed. 2. Anti tip bracket not installed properly need to be tapconed to the floor. 1/9/2025 - PREVIOUS INSPECTION NOTES 1/9/24 1. No E-cals on site 2. Anti tip bracket not installed properly 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven.
BLD - BUILDING FINAL 01/21/2025 Disapproved - NO FEE BTAYLOR
Note: 1-21-25 1. Energy cals on site do not match equiptment that is installed. 2. Anti tip bracket not installed properly need to be tapconed to the floor. 1/9/2025 - PREVIOUS INSPECTION NOTES 1/9/24 1. No E-cals on site 2. Anti tip bracket not installed properly 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven.
BLD - BUILDING FINAL 01/09/2025 Disapproved - NO FEE MKRASKI
Note: 1/9/24 1. No E-cals on siteFBC [A] 107.4 2. Anti tip bracket not installed properly FBCR M1901.2 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco FBCR P2606.1, R402.4.1.1 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven.
BLD - BUILDING FINAL 12/27/2024 Disapproved -FEE REQUIRED BTAYLOR
Note: 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven.
ROW - FINAL APRON (AFTER POUR) 12/18/2024 APPROVED - AS NOTED RGROSS
Note: The cracks in the driveway are not a case of structural construction defect, but were caused by natural explansion and contraction of concrete. Builder takes full responsibilty for warranting there driveway products. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
ROW - STORMWATER FINAL 12/18/2024 APPROVED RGROSS
Note: Inspector Notes from Inspection 9272 The cracks in the driveway are not a case of structural construction defect, but were caused by natural explansion and contraction of concrete. Builder takes full responsibilty for warranting there driveway products. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) This was inspected on 12/17/24. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
U -UTILITY RESIDENTIAL FINAL 12/06/2024 FINAL APPROVED BWRIGHT
ROW - STORMWATER FINAL 12/06/2024 Disapproved - NO FEE FSLADISH
Note: 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
ROW - FINAL APRON (AFTER POUR) 12/06/2024 Disapproved - NO FEE FSLADISH
Note: 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
BLD - BUILDING FINAL 12/06/2024 Disapproved - NO FEE BTAYLOR
Note: 12-6-24 1. Inspection not even started house doesn't even have power.
ELECTRIC - EARLY POWER 12/05/2024 APPROVED - AS NOTED BTAYLOR
Note: 12/3/2024 - PREVIOUS INSPECTION NOTES 11/22/2024 - PREVIOUS INSPECTION NOTES 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island. 12-5-24 1. Emailed FPL at 12:48.
ELECTRIC - EARLY POWER 12/03/2024 CANCELLED BY APPLICANT BTAYLOR
Note: 11/22/2024 - PREVIOUS INSPECTION NOTES 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island.
ELECTRIC - EARLY POWER 11/22/2024 Disapproved - NO FEE BTAYLOR
Note: 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island.
U-CROSS CONNECTION 11/22/2024 APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/19/2024 APPROVED - AS NOTED FSLADISH
Note: 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/19/2024 APPROVED - AS NOTED FSLADISH
Note: 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/05/2024 Disapproved - NO FEE FSLADISH
Note: 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A)
ROW- PRE-APRON (PRE-POUR) 03/15/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 3/13/2024 - PREVIOUS INSPECTION NOTES THE FORM BOARD ALONG ROAD EDGE NEEDS TO BE FORMED UP WITH STAKES AND NEED TO GIVE YOU 6" OF CONCRETE IN THE APRON. NOT FEEING YOU THIS TIME
ROW- PRE-APRON (PRE-POUR) 03/13/2024 Disapproved - NO FEE PFLANAGAN
Note: THE FORM BOARD ALONG ROAD EDGE NEEDS TO BE FORMED UP WITH STAKES AND NEED TO GIVE YOU 6" OF CONCRETE IN THE APRON. NOT FEEING YOU THIS TIME
ROW- PROJECT STATUS 02/28/2024 APPROVED GBERTOLA
Note: CHECKING THE CULVERT PIPE AND GRADE IN THE BACK AND FRONT
LATH/BRICK/ WATER BARRIER 12/18/2023 APPROVED BTAYLOR
INSULATION 11/29/2023 APPROVED BTAYLOR
Note: 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23: * Insulation at garage wall is blown in. * Firestop is insufficient at Dryer exhaust, Powder room & Master bathroom plumbing vent stacks allowing air space into attic area. * Firestop missing at right side bathroom - pack out wall. Please resecure cardboard baffles at front entry & back left lanai above slider.
INSULATION 11/27/2023 Disapproved - NO FEE RSIMS
Note: 11/27/23: * Insulation at garage wall is blown in. * Firestop is insufficient at Dryer exhaust, Powder room & Master bathroom plumbing vent stacks allowing air space into attic area. * Firestop missing at right side bathroom - pack out wall. Please resecure cardboard baffles at front entry & back left lanai above slider.
U - SEWER TIE IN 11/27/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ALL ROUGH 11/21/2023 APPROVED - AS NOTED BTAYLOR
Note: 11/15/2023 - PREVIOUS INSPECTION NOTES 11-15-23 1. No fire alarms in any of the bedrooms. 2. Wires in electrical panel are not phased out. 11-21-23 1. Weather head is way to big. Needs to be between 18" and 3' tall. 2. Wires above panel box need to be secured within 12" from top of panel box.
ALL ROUGH 11/15/2023 Disapproved - NO FEE BTAYLOR
Note: 11-15-23 1. No fire alarms in any of the bedrooms. 2. Wires in electrical panel are not phased out.
GRAVITY SEWER TEST 11/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROOF VALLEY & METAL 06/07/2023 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/19/2023 APPROVED BTAYLOR
Note: 5/17/2023 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/17/2023 CANCELLED BY APPLICANT BTAYLOR
TIE BEAM / LINTEL 04/18/2023 APPROVED BTAYLOR
FOUND SURVEY APPROVED (OFFICE) 04/13/2023 APPROVED TDOAK
MONOLITHIC SLAB 03/30/2022 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase all items addressed
MONOLITHIC SLAB 03/28/2022 Disapproved - NO FEE TSTAUFFACHER
Note: THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase
MONOLITHIC SLAB 03/21/2022 Disapproved - NO FEE DCUSHING
Note: Edges caved in everywhere Column pad steel covered with dirt, multipe
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2022 CANCELLED BY INSPECTOR MGIBSON
Note: WRONG INSPECTION CALLED IN
PLUMBING 1ST ROUGH UNDERGROUND 03/04/2022 APPROVED - AS NOTED MGIBSON
Note: THIS IS A REINSPECTION PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1'' MEET WITH PLUMBING CONTRACTOR ALL WAS TAKEN CARE OF
PLUMBING 1ST ROUGH UNDERGROUND 02/15/2022 CANCELLED BY APPLICANT AWS_IVR
PLUMBING 1ST ROUGH UNDERGROUND 02/15/2022 Disapproved - NO FEE MGIBSON
Note: PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1''
WATER METER INSTALLATION REQUEST 02/14/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 01/27/2025 01/29/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 11/04/2024 11/04/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM nothing attached
BADMIN INFORMATION 09/09/2024 09/09/2024
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM CAN NOT SCHEDULE FINAL SURVEY INSPECTION. MAIN CONTRACTOR CERTIFICATE NOT ACTIVE
BADMIN INFORMATION 09/06/2024 09/06/2024
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO FINAL SURVEY.PDF
BADMIN INFORMATION 09/03/2024 09/03/2024
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Could not schedule the final survey review Expired NOC. Provide a current one
ENGIN1 COMPLETE 04/11/2023 04/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/11/2023 04/11/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/22/2023 03/22/2023
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM PAID ALREADY
PLUM COMPLETE 02/25/2022 02/25/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 02/24/2022 02/25/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
PLUM HOLD 02/24/2022 02/25/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves.
PLUM HOLD 02/18/2022 02/22/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves.
BLD HOLD 02/18/2022 02/22/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves.
MECH COMPLETE 08/25/2021 08/25/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/25/2021 08/26/2021
Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 08/25/2021 08/26/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/20/2021 08/20/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 08/20/2021 08/23/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS 1. Revised plans where alternated and resubmitted. Per the architects copyright and State of Florida laws, plans are required to be revised and resubmitted.
MECH HOLD 08/20/2021 08/23/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. (Second Request)
ELEC HOLD 08/20/2021 08/23/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Can not write on sealed plans
ZON COMPLETE 08/20/2021 08/20/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 08/20/2021 08/24/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
SWALE COMPLETE 08/20/2021 12/01/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 08/12/2021 08/12/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Per 302.6 2020 FBCR, 20 min rated door is required. Plans shows a 2868 but a callout for 6068 slider is noted per the door schedule. A revision is required to reflect the requirements of the Code section mentioned above. 2. Product Approval for the proposed roof underlayment is not correct. Please revise and resubmit.
CUSVC COMPLETE 08/12/2021 08/19/2021
Note: Released By: ALYSSA ROSCOE - -
ELEC HOLD 08/12/2021 08/13/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need outlet on the front of the house. NEC 2017 210.52 (E) (1) Outlets in garage need to be GFCI protected NEC 2017 210.8
ENGIN1 HOLD 08/12/2021 08/12/2021
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No Survey or Site Plan in submittal
LOCATE COMPLETE 08/12/2021 08/16/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 08/12/2021 08/13/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. 2. Duct Layout needs to be signed by AC contractor
SW1 HOLD 08/12/2021 08/19/2021
Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM no site plan uploaded for review
ZON HOLD 08/12/2021 08/13/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Please submit a Site Plan Landscape plan needs: Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. Please include the proposed shrubs that will provide coverage for the mechanical equipment. also provide what type of grass will be used at this site and if it will require an irrigation system.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/04/2025
SURCHARGE FS 533.721 ¤2.00 11/04/2024
SURCHARGE - FS 468.631 ¤2.00 11/04/2024
SW ENG INSPECTION 80 ¤80.00 11/04/2024
SW ENG REINSPECTION 20 ¤20.00 11/04/2024
ADJUSTMENT 10% (¤15.00) 11/04/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/04/2024
INSPECTION - RESIDENTIAL ¤120.00 11/04/2024
Fees Total Due: ¤0.00 Total Paid: ¤271.50