Permit #2024091017
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00280-0160 |
| Total Square Footage: 0 sqft |
| Block: 00280 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: (386) 547-0409 |
| Location Address: 13 SERENADE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/04/2024 |
| NOC: RECORDED |
| Applicant name: JEFFREY G SPRAGUE |
| Owner: INTERCOASTAL CONSTRUCTION |
|
Address 33 SENECA PATH PALM COAST, FL 32164 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤10,000.00 |
| Job Description: REF: 2023021245 - SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2023021245 |
Contractor
JGS DESIGN ASSOCIATES, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 INDIAN MOUND CT FLAGLER BEACH, FL 32136 |
CBC1260630 (Exp: 08/31/2026) | 386-585-0958 |
Sub Contractors
GREGORY ALLEN HENRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1332 SUNSET BLVD DAYTONA BEACH, FL 32117 |
EC13009193 (Exp: 08/31/2026) | 386-679-6908 |
BRETT FORREST L'AMIE
| Status | Location Address | State License Number |
| INACTIVE |
919 VALENCIA ROAD SOUTH DAYTONA, FL 32119 |
CFC1428647 (Exp: 08/31/2026) |
MICHAEL A TORRES JR
| Status | Location Address | State License Number | Phone |
| INACTIVE |
846 JASMINE AVE HOLLY HILL , FL 32117 |
CAC1815003 (Exp: 08/31/2026) | 386-212-9442 |
JEFFREY G SPRAGUE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 INDIAN MOUND CT FLAGLER BEACH, FL 32136 |
CBC1260630 (Exp: 08/31/2026) | 386-585-0958 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/30/2025 | FINAL APPROVED | BTAYLOR |
| Note: 1/21/2025 - PREVIOUS INSPECTION NOTES 1-21-25 1. Energy cals on site do not match equiptment that is installed. 2. Anti tip bracket not installed properly need to be tapconed to the floor. 1/9/2025 - PREVIOUS INSPECTION NOTES 1/9/24 1. No E-cals on site 2. Anti tip bracket not installed properly 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven. | |||
| BLD - BUILDING FINAL | 01/21/2025 | Disapproved - NO FEE | BTAYLOR |
| Note: 1-21-25 1. Energy cals on site do not match equiptment that is installed. 2. Anti tip bracket not installed properly need to be tapconed to the floor. 1/9/2025 - PREVIOUS INSPECTION NOTES 1/9/24 1. No E-cals on site 2. Anti tip bracket not installed properly 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven. | |||
| BLD - BUILDING FINAL | 01/09/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1/9/24 1. No E-cals on siteFBC [A] 107.4 2. Anti tip bracket not installed properly FBCR M1901.2 3. Garage door opener outlet is required to be GFCI protected NEC 210.8 4. Dryer is required to be GFCI protected NEC 210.8 5. Hose bib on back of home must be secured and seal penitration if water line into stucco FBCR P2606.1, R402.4.1.1 12/27/2024 - PREVIOUS INSPECTION NOTES 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven. | |||
| BLD - BUILDING FINAL | 12/27/2024 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 12/6/2024 - PREVIOUS INSPECTION NOTES 12-6-24 1. Inspection not even started house doesn't even have power. 12-27-24 1. No address. 2. No power at island. 3. Left wall in living room no power. 4. No power on master outside wall. 5. No power in front bedroom outside wall. 6. No energy cals. 7. Air handler breaker to high. 8. Sink in master bath does not drain. 9. Half bath sink does not drain. 10. No anti tip for oven. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/18/2024 | APPROVED - AS NOTED | RGROSS |
| Note: The cracks in the driveway are not a case of structural construction defect, but were caused by natural explansion and contraction of concrete. Builder takes full responsibilty for warranting there driveway products. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| ROW - STORMWATER FINAL | 12/18/2024 | APPROVED | RGROSS |
| Note: Inspector Notes from Inspection 9272 The cracks in the driveway are not a case of structural construction defect, but were caused by natural explansion and contraction of concrete. Builder takes full responsibilty for warranting there driveway products. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) This was inspected on 12/17/24. 12/6/2024 - PREVIOUS INSPECTION NOTES 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| U -UTILITY RESIDENTIAL FINAL | 12/06/2024 | FINAL APPROVED | BWRIGHT |
| ROW - STORMWATER FINAL | 12/06/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| ROW - FINAL APRON (AFTER POUR) | 12/06/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 12/6/24 AFTER CONFERING WITH STORMWATER LEAD INSPECTOR GABE BERTOLA, I HAVE DETERMINED THAT AS I NOTED IN YOUR PREVIOUS INSPECTION, DUE TO THE LENGTH AND EXTENT OF THE CRACKS ALREADY NOTED AND PHOTOGRAPHED IN THE DRIVEWAY, YOU WILL BE REQUIRED TO REPOUR DAMAGED AREA BEFORE ROW FINAL PASSAGE. i WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTIONS AND SCHEDULE A NEW PREPOUR INSPECTION WHEN READY. Inspector Notes from Inspection 9465 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| BLD - BUILDING FINAL | 12/06/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 12-6-24 1. Inspection not even started house doesn't even have power. | |||
| ELECTRIC - EARLY POWER | 12/05/2024 | APPROVED - AS NOTED | BTAYLOR |
| Note: 12/3/2024 - PREVIOUS INSPECTION NOTES 11/22/2024 - PREVIOUS INSPECTION NOTES 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island. 12-5-24 1. Emailed FPL at 12:48. | |||
| ELECTRIC - EARLY POWER | 12/03/2024 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: 11/22/2024 - PREVIOUS INSPECTION NOTES 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island. | |||
| ELECTRIC - EARLY POWER | 11/22/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 11-22-24 1. Outlet next to a/c is not safed off. 2. Light in attic is not safed off. 3. Outside outlets need to weather resistant. 4. Outlets under island over hang need to be moved to the sides of the island. | |||
| U-CROSS CONNECTION | 11/22/2024 | APPROVED | BWRIGHT |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/19/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/19/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 11/19/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ***** INSPECTORS NOTE. YOUR DRIVEWAY IS CRACKED FROM EDGE TO EDGE PARRALLEL TO THE ROAD ABOVE THE CULVERT PIPE. IT IS ALSO CRACKED FROM 1/2 WAY UP THE DRIVEWAY TO THE GARAGE PERPENDICULAR TO THE ROAD. YOU NEED TO INSPECT IT AND DEPENDING ON THE EXTENT OF THE DAMAGE, YOU MAY BE REQUIRED TO REPOUR THE DRIVEWAY.****** APPROVING AS NOTED. SEE PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 11/19/24 FFE ELEVATION REQUIRED PROVIDED AT THE TIME OF THIS FINAL SURVEY INSPECTION. APPROVED AS NOTED. _________________________________________________________________________________________________________________________ 11/5/2024 - PREVIOUS INSPECTION NOTES 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/05/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 11/5/24 please include ffe on all iimproved adjoining lots. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) | |||
| ROW- PRE-APRON (PRE-POUR) | 03/15/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTION MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 3/13/2024 - PREVIOUS INSPECTION NOTES THE FORM BOARD ALONG ROAD EDGE NEEDS TO BE FORMED UP WITH STAKES AND NEED TO GIVE YOU 6" OF CONCRETE IN THE APRON. NOT FEEING YOU THIS TIME | |||
| ROW- PRE-APRON (PRE-POUR) | 03/13/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: THE FORM BOARD ALONG ROAD EDGE NEEDS TO BE FORMED UP WITH STAKES AND NEED TO GIVE YOU 6" OF CONCRETE IN THE APRON. NOT FEEING YOU THIS TIME | |||
| ROW- PROJECT STATUS | 02/28/2024 | APPROVED | GBERTOLA |
| Note: CHECKING THE CULVERT PIPE AND GRADE IN THE BACK AND FRONT | |||
| LATH/BRICK/ WATER BARRIER | 12/18/2023 | APPROVED | BTAYLOR |
| INSULATION | 11/29/2023 | APPROVED | BTAYLOR |
| Note: 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23: * Insulation at garage wall is blown in. * Firestop is insufficient at Dryer exhaust, Powder room & Master bathroom plumbing vent stacks allowing air space into attic area. * Firestop missing at right side bathroom - pack out wall. Please resecure cardboard baffles at front entry & back left lanai above slider. | |||
| INSULATION | 11/27/2023 | Disapproved - NO FEE | RSIMS |
| Note: 11/27/23: * Insulation at garage wall is blown in. * Firestop is insufficient at Dryer exhaust, Powder room & Master bathroom plumbing vent stacks allowing air space into attic area. * Firestop missing at right side bathroom - pack out wall. Please resecure cardboard baffles at front entry & back left lanai above slider. | |||
| U - SEWER TIE IN | 11/27/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ALL ROUGH | 11/21/2023 | APPROVED - AS NOTED | BTAYLOR |
| Note: 11/15/2023 - PREVIOUS INSPECTION NOTES 11-15-23 1. No fire alarms in any of the bedrooms. 2. Wires in electrical panel are not phased out. 11-21-23 1. Weather head is way to big. Needs to be between 18" and 3' tall. 2. Wires above panel box need to be secured within 12" from top of panel box. | |||
| ALL ROUGH | 11/15/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 11-15-23 1. No fire alarms in any of the bedrooms. 2. Wires in electrical panel are not phased out. | |||
| GRAVITY SEWER TEST | 11/15/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROOF VALLEY & METAL | 06/07/2023 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/19/2023 | APPROVED | BTAYLOR |
| Note: 5/17/2023 - PREVIOUS INSPECTION NOTES | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/17/2023 | CANCELLED BY APPLICANT | BTAYLOR |
| TIE BEAM / LINTEL | 04/18/2023 | APPROVED | BTAYLOR |
| FOUND SURVEY APPROVED (OFFICE) | 04/13/2023 | APPROVED | TDOAK |
| MONOLITHIC SLAB | 03/30/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase all items addressed | |||
| MONOLITHIC SLAB | 03/28/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Edges caved in everywhere Column pad steel covered with dirt, multipe 03/28/2022: Missing dowel right side of garage Missing ground wire Missing island electrical chase | |||
| MONOLITHIC SLAB | 03/21/2022 | Disapproved - NO FEE | DCUSHING |
| Note: Edges caved in everywhere Column pad steel covered with dirt, multipe | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/16/2022 | CANCELLED BY INSPECTOR | MGIBSON |
| Note: WRONG INSPECTION CALLED IN | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/04/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS IS A REINSPECTION PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1'' MEET WITH PLUMBING CONTRACTOR ALL WAS TAKEN CARE OF | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/15/2022 | CANCELLED BY APPLICANT | AWS_IVR |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/15/2022 | Disapproved - NO FEE | MGIBSON |
| Note: PLANS DO NOT INDICATE L/T AND WATER PIPES GOING THROUGH FOOTERS IN MULTIPLE PLACES NEED SLEEVED WITH 2X THE DIAMETER OF PIPE PASSING THROUGH EXP..3/4'' NEEDS 1 1/2'' 1/2'' NEEDS 1'' | |||
| WATER METER INSTALLATION REQUEST | 02/14/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 01/27/2025 | 01/29/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 11/04/2024 | 11/04/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM nothing attached | |||
| BADMIN | INFORMATION | 09/09/2024 | 09/09/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM CAN NOT SCHEDULE FINAL SURVEY INSPECTION. MAIN CONTRACTOR CERTIFICATE NOT ACTIVE | |||
| BADMIN | INFORMATION | 09/06/2024 | 09/06/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO FINAL SURVEY.PDF | |||
| BADMIN | INFORMATION | 09/03/2024 | 09/03/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Could not schedule the final survey review Expired NOC. Provide a current one | |||
| ENGIN1 | COMPLETE | 04/11/2023 | 04/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/11/2023 | 04/11/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/22/2023 | 03/22/2023 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM PAID ALREADY | |||
| PLUM | COMPLETE | 02/25/2022 | 02/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/24/2022 | 02/25/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 02/24/2022 | 02/25/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| PLUM | HOLD | 02/18/2022 | 02/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| BLD | HOLD | 02/18/2022 | 02/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Plans submitted were altered. Plans altered by someone other than the Engineer of record are not accepted and in violation of F.S. 568. 2. Per the inspector comments dated 2/15/2022, plans do not indicate size and multiple locations of the propose sleeve. Plans call-out a 6 inch sleeve in one location. A revision to the plans required to reflect the multiple locations and sizes of the proposed sleeves. | |||
| MECH | COMPLETE | 08/25/2021 | 08/25/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/25/2021 | 08/26/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/25/2021 | 08/26/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/20/2021 | 08/20/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS 1. Revised plans where alternated and resubmitted. Per the architects copyright and State of Florida laws, plans are required to be revised and resubmitted. | |||
| MECH | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. (Second Request) | |||
| ELEC | HOLD | 08/20/2021 | 08/23/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Can not write on sealed plans | |||
| ZON | COMPLETE | 08/20/2021 | 08/20/2021 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/20/2021 | 08/24/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/20/2021 | 12/01/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/12/2021 | 08/12/2021 |
| Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Per 302.6 2020 FBCR, 20 min rated door is required. Plans shows a 2868 but a callout for 6068 slider is noted per the door schedule. A revision is required to reflect the requirements of the Code section mentioned above. 2. Product Approval for the proposed roof underlayment is not correct. Please revise and resubmit. | |||
| CUSVC | COMPLETE | 08/12/2021 | 08/19/2021 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need outlet on the front of the house. NEC 2017 210.52 (E) (1) Outlets in garage need to be GFCI protected NEC 2017 210.8 | |||
| ENGIN1 | HOLD | 08/12/2021 | 08/12/2021 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No Survey or Site Plan in submittal | |||
| LOCATE | COMPLETE | 08/12/2021 | 08/16/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment on Manual J/S exceeds the maximum of 1.15 times the load calculated. 2. Duct Layout needs to be signed by AC contractor | |||
| SW1 | HOLD | 08/12/2021 | 08/19/2021 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM no site plan uploaded for review | |||
| ZON | HOLD | 08/12/2021 | 08/13/2021 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Please submit a Site Plan Landscape plan needs: Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. Please include the proposed shrubs that will provide coverage for the mechanical equipment. also provide what type of grass will be used at this site and if it will require an irrigation system. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/04/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/04/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/04/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/04/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 11/04/2024 |
| ADJUSTMENT 10% | (¤15.00) | 11/04/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/04/2024 |
| INSPECTION - RESIDENTIAL | ¤120.00 | 11/04/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤271.50 |