I want to search for...
Permit #2024100009
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7034-00280-0010 |
| Block: 00280 |
| Subdivision: 7034 - |
| Job Phone: 386-931-5275 |
| Location Address: 1 EASTWICK PL |
| Type: DR - DRIVEWAY |
| Issue Date: 10/23/2024 |
| NOC: Unknown |
| Applicant name: DANIELLE COPSY |
| Owner: FERREIRA ANTONIO L & MARIA N H&W |
|
Address 732 LINDEN AVE ELIZABETH, NJ 07202 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤2,400.00 |
| Job Description: CONCRETE DRIVEWAY |
| Type: CN |
Contractor
J & D COPSY ENTERPRISES, INC
| Status | Location Address | Mailing Address | Phone |
| INACTIVE |
2280 WEST COUNTY ROAD BUNNELL, FL 32110 |
2006 BUNNELL, FL 32110 |
386-931-5275 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 10/25/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE TO MITER END FORMS IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ----------------------------------------------------------------------------- 10/24/2024 - PREVIOUS INSPECTION NOTES 10/24/24 YOUR MITERED ENDS MEASUREMENTS NEED TO BE 18" FROMTHE TOP OF THE MITERED END FORMBOARDS TO THE EDGE OF THE CULVERT PIPE ON BOTH SIDES. THE BOTTOM OF THE CULVERT PIPE NEEDS TO BE 9" FROM THE FORMBOARDS TO THE EDGE OF THE CULVERT PIPE ON BOTH SIDES. AT THE BOTOM OF THE CULVERT PIPE END TO THE FORMBOARD SHOULD BE NO FURTHER THAN 6" AWAY. PLEASE FEEL FREE TO REACH OUT IF YOU DO NOT UNDERSTAND WHAT IS REQUIRED. I AM NOT GOING TO FEE YOU FOR TODAYS INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR A REINSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/24/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 10/24/24 YOUR MITERED ENDS MEASUREMENTS NEED TO BE 18" FROMTHE TOP OF THE MITERED END FORMBOARDS TO THE EDGE OF THE CULVERT PIPE ON BOTH SIDES. THE BOTTOM OF THE CULVERT PIPE NEEDS TO BE 9" FROM THE FORMBOARDS TO THE EDGE OF THE CULVERT PIPE ON BOTH SIDES. AT THE BOTOM OF THE CULVERT PIPE END TO THE FORMBOARD SHOULD BE NO FURTHER THAN 6" AWAY. PLEASE FEEL FREE TO REACH OUT IF YOU DO NOT UNDERSTAND WHAT IS REQUIRED. I AM NOT GOING TO FEE YOU FOR TODAYS INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR A REINSPECTION. | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 10/01/2024 | 10/03/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 10/01/2024 | 10/01/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/01/2024 | 10/01/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please use a copy of the survey from this property. I will email a copy. Please make sure that you have width of driveway and walkway shown on the site plan | |||
| ZON | COMPLETE | 10/01/2024 | 10/01/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 10/23/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/23/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 10/23/2024 |
| SW ENG PRE APRON | ¤30.00 | 10/23/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/23/2024 |
| SITE PLAN 15 | ¤15.00 | 10/23/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤312.00 |