Permit #2024100318

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7011-00010-1680
CONDITIONED SPACE: 316 sqft
OPENED PORCH (WITH ROOF) : 499 sqft
Total Square Footage: 815 sqft
Block: 00010
Subdivision: 7011 -
Job Phone: 530-308-7323
Location Address: 204 BEACHWAY DR
Type: BA - BUILDING ADDITION
Issue Date: 11/09/2024
NOC: RECORDED
Applicant name: DONALD CABRAL
Owner: INDWELLER ARTISTIC INC

Address

774 MUNICH CIR

CANADA N2V 2N6, 0

Address

WATERLOO ON

CANADA N2V 2N6, 0

Lot: 1680
Contracted Stated Job Value: ¤120,000.00
Job Description: Bedroom Bathroom addition. Lanai addition
Type: CN

Contractor

DC CONSTRUCTION PALM COAST LLC
Status Location Address State License Number
ACTIVE

109 UNIVERSAL TRAIL

,

CGC1531039 (Exp: 08/31/2026)

Sub Contractors

SCOTT R WOODARD
Status Location Address State License Number Phone
ACTIVE

51 PINEAPPLE DRIVE

PALM COAST, FL 32164

ES12000383 (Exp: 08/31/2026) 386-264-4964
SCOTT PATRICK RAYMOND
Status Location Address State License Number
ACTIVE

61 FRENEAU LN

PALM COAST, FL 32137

RF11067787 (Exp: 08/31/2027)
JUAN EUGENIO CAMPELO
Status Location Address State License Number Phone Fax
INACTIVE

114 ALLGOOD CIRCLE SUITE #101

ST AUGUSTINE, FL 32086

CAC1813797 (Exp: 08/31/2026) 904-824-4275 904-824-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/07/2025 FINAL APPROVED MCONTRYMAN
U -UTILITY RESIDENTIAL FINAL 05/07/2025 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/25/2025 APPROVED FSLADISH
Note: 3/19/2025 - PREVIOUS INSPECTION NOTES 03/19/25 TPOLACEK** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL FROM THE FFE TO THE SOD ELEVATION ALONG SIDE THE STRUCTURE. COPC REQUIRES 4" OF FALL FOR CBS AND 6" FOR WOOD. THE FINAL SURVEY DOES NOT INDICATE WHAT TYPE OF CONSTRUCTION WAS USED HOWEVER THERE IS NOT EVEN THE 4" FOR CBS. THE SURVEY IONDICATES ONLY A .07 FALL ALONG ADDITION. THE SITE PLAN HAS PROPOSED ELEVATION OF 26.20 AND MOVING BACVK 26.26.30 WITH A 26.20 AT THE LEFT REAR CORNER OF LANAI. PLEASE SEE CODE BELOW AND ATTACHED SNIPS THAT ARE MARKED UP. 12 Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/25/2025 APPROVED FSLADISH
Note: 4/25/25 DRAINAGE IN THE FIELD WORKS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 04/25/2025 APPROVED FSLADISH
Note: 4/25/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/19/2025 Disapproved - NO FEE TPOLACEK
Note: 03/19/25 TPOLACEK** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL FROM THE FFE TO THE SOD ELEVATION ALONG SIDE THE STRUCTURE. COPC REQUIRES 4" OF FALL FOR CBS AND 6" FOR WOOD. THE FINAL SURVEY DOES NOT INDICATE WHAT TYPE OF CONSTRUCTION WAS USED HOWEVER THERE IS NOT EVEN THE 4" FOR CBS. THE SURVEY IONDICATES ONLY A .07 FALL ALONG ADDITION. THE SITE PLAN HAS PROPOSED ELEVATION OF 26.20 AND MOVING BACVK 26.26.30 WITH A 26.20 AT THE LEFT REAR CORNER OF LANAI. PLEASE SEE CODE BELOW AND ATTACHED SNIPS THAT ARE MARKED UP. 12 Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures.
INSULATION 01/08/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling.
LATH/BRICK/ WATER BARRIER 01/08/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling. *** NOTES ADDED BY JSTEWART 1/7/2025 3:16:16 PM *** For Lanai ceiling only
ALL ROUGH 01/07/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling.
WALL SHEATHING 01/06/2025 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 01/06/2025 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/20/2024 APPROVED FWILLIS
Note: 12/19/2024 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2024 CANCELLED BY APPLICANT FWILLIS
ROOF VALLEY & METAL 12/18/2024 APPROVED MCONTRYMAN
Note: 12/17/2024 - PREVIOUS INSPECTION NOTES
ROOF VALLEY & METAL 12/17/2024 CANCELLED BY APPLICANT FWILLIS
TIE BEAM / LINTEL 12/09/2024 APPROVED FWILLIS
MONOLITHIC SLAB 11/26/2024 APPROVED FWILLIS
Note: 11/25/2024 - PREVIOUS INSPECTION NOTES REBAR MISSING AS PER APPROVED DRAWINGS. DOWELS NOT INSTALLED AS PER APPROVED DRAWINGS.
MONOLITHIC SLAB 11/25/2024 Disapproved - NO FEE FWILLIS
Note: REBAR MISSING AS PER APPROVED DRAWINGS. DOWELS NOT INSTALLED AS PER APPROVED DRAWINGS.
PLUMBING 1ST ROUGH UNDERGROUND 11/15/2024 APPROVED MGIBSON

Review History

Department Status Date In Date Out
MECH COMPLETE 11/01/2024 11/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/01/2024 11/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 11/01/2024 11/07/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 11/01/2024 11/01/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH HOLD 10/22/2024 10/25/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by AC contractor showing supply and return air for bedroom/ bathroom (Second Request) 2. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition 3. Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2023 8Th edition
ELEC HOLD 10/22/2024 10/28/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need outlet in bathroom next to sink. NEC 2020 210.52 (D) 2. Need smoke alarm inside of bedroom. FRC 2020 314 3. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4. 2nd REQUEST
BLD HOLD 10/22/2024 10/28/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise all general notes and engineering notes to show current code years. (Second Request) 2. Provide soffit dimensions on plans. 107.2.1 3. Provide soffit detail showing midpoint span if over than 12 inches 704.2.1-704.2.4 FBC Residential 2023
ZON COMPLETE 10/22/2024 10/22/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 10/08/2024 10/14/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Plans shall be in compliance with the current building codes and referenced standards. 2023 Florida Building Code, Residential , 8th Edition. 2. Needs soffit detail per FBC [A] 107.3 3. Needs EOR acceptance of truss engineering FBC [A] 107.3
ELEC HOLD 10/08/2024 10/11/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need outlet in bathroom next to sink. NEC 2020 210.52 (D) 2. Need smoke alarm inside of bedroom. FRC 2020 314 3. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4.
ENGIN1 COMPLETE 10/08/2024 10/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 10/08/2024 10/09/2024
MECH HOLD 10/08/2024 10/09/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calc needs to be for addition. Not total house. Heatlaod can be from total house. Revise energy calcs. Submit as one document except for state card. 2. Provide duct layout signed by AC contractor showing supply and return air for bedroom/ bathroom
PLUM COMPLETE 10/08/2024 10/14/2024
Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM
SW1 COMPLETE 10/08/2024 10/14/2024
Note: Released By: TOM POLACEK - (386)346-8986 -
ZON COMPLETE 10/08/2024 10/08/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤45.36) 11/09/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/09/2024
INSPECTION - RESIDENTIAL ¤330.00 11/09/2024
PLAN REVIEW - RESIDENTIAL ¤93.60 11/09/2024
SURCHARGE FS 533.721 ¤4.08 11/09/2024
SURCHARGE - FS 468.631 ¤6.12 11/09/2024
SW ENG - INSPECTION 20 ¤20.00 11/09/2024
SW ENG - REVIEW 20 ¤20.00 11/09/2024
SITE PLAN 30 ¤30.00 11/09/2024
Fees Total Due: ¤0.00 Total Paid: ¤488.44