Permit #2024100318
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7011-00010-1680 |
| CONDITIONED SPACE: 316 sqft |
| OPENED PORCH (WITH ROOF) : 499 sqft |
| Total Square Footage: 815 sqft |
| Block: 00010 |
| Subdivision: 7011 - |
| Job Phone: 530-308-7323 |
| Location Address: 204 BEACHWAY DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 11/09/2024 |
| NOC: RECORDED |
| Applicant name: DONALD CABRAL |
| Owner: INDWELLER ARTISTIC INC |
|
Address 774 MUNICH CIR CANADA N2V 2N6, 0 |
|
Address WATERLOO ON CANADA N2V 2N6, 0 |
| Lot: 1680 |
| Contracted Stated Job Value: ¤120,000.00 |
| Job Description: Bedroom Bathroom addition. Lanai addition |
| Type: CN |
Contractor
DC CONSTRUCTION PALM COAST LLC
| Status | Location Address | State License Number |
| ACTIVE |
109 UNIVERSAL TRAIL , |
CGC1531039 (Exp: 08/31/2026) |
Sub Contractors
SCOTT R WOODARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
51 PINEAPPLE DRIVE PALM COAST, FL 32164 |
ES12000383 (Exp: 08/31/2026) | 386-264-4964 |
SCOTT PATRICK RAYMOND
| Status | Location Address | State License Number |
| ACTIVE |
61 FRENEAU LN PALM COAST, FL 32137 |
RF11067787 (Exp: 08/31/2027) |
JUAN EUGENIO CAMPELO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
114 ALLGOOD CIRCLE SUITE #101 ST AUGUSTINE, FL 32086 |
CAC1813797 (Exp: 08/31/2026) | 904-824-4275 | 904-824-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/07/2025 | FINAL APPROVED | MCONTRYMAN |
| U -UTILITY RESIDENTIAL FINAL | 05/07/2025 | FINAL APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/25/2025 | APPROVED | FSLADISH |
| Note: 3/19/2025 - PREVIOUS INSPECTION NOTES 03/19/25 TPOLACEK** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL FROM THE FFE TO THE SOD ELEVATION ALONG SIDE THE STRUCTURE. COPC REQUIRES 4" OF FALL FOR CBS AND 6" FOR WOOD. THE FINAL SURVEY DOES NOT INDICATE WHAT TYPE OF CONSTRUCTION WAS USED HOWEVER THERE IS NOT EVEN THE 4" FOR CBS. THE SURVEY IONDICATES ONLY A .07 FALL ALONG ADDITION. THE SITE PLAN HAS PROPOSED ELEVATION OF 26.20 AND MOVING BACVK 26.26.30 WITH A 26.20 AT THE LEFT REAR CORNER OF LANAI. PLEASE SEE CODE BELOW AND ATTACHED SNIPS THAT ARE MARKED UP. 12 Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/25/2025 | APPROVED | FSLADISH |
| Note: 4/25/25 DRAINAGE IN THE FIELD WORKS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 04/25/2025 | APPROVED | FSLADISH |
| Note: 4/25/25 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/19/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 03/19/25 TPOLACEK** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL FROM THE FFE TO THE SOD ELEVATION ALONG SIDE THE STRUCTURE. COPC REQUIRES 4" OF FALL FOR CBS AND 6" FOR WOOD. THE FINAL SURVEY DOES NOT INDICATE WHAT TYPE OF CONSTRUCTION WAS USED HOWEVER THERE IS NOT EVEN THE 4" FOR CBS. THE SURVEY IONDICATES ONLY A .07 FALL ALONG ADDITION. THE SITE PLAN HAS PROPOSED ELEVATION OF 26.20 AND MOVING BACVK 26.26.30 WITH A 26.20 AT THE LEFT REAR CORNER OF LANAI. PLEASE SEE CODE BELOW AND ATTACHED SNIPS THAT ARE MARKED UP. 12 Sod elevation Sec 300.01 (A)(1)(C)(6) Sec300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. | |||
| INSULATION | 01/08/2025 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling. | |||
| LATH/BRICK/ WATER BARRIER | 01/08/2025 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling. *** NOTES ADDED BY JSTEWART 1/7/2025 3:16:16 PM *** For Lanai ceiling only | |||
| ALL ROUGH | 01/07/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 1/7/2025 3:15:28 PM *** 1. Please install mechanical fastener at bath exhaust duct to fan assembly. 2. Added a lath inspection for Lanai ceiling. | |||
| WALL SHEATHING | 01/06/2025 | APPROVED | FWILLIS |
| LATH/BRICK/ WATER BARRIER | 01/06/2025 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/20/2024 | APPROVED | FWILLIS |
| Note: 12/19/2024 - PREVIOUS INSPECTION NOTES | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/19/2024 | CANCELLED BY APPLICANT | FWILLIS |
| ROOF VALLEY & METAL | 12/18/2024 | APPROVED | MCONTRYMAN |
| Note: 12/17/2024 - PREVIOUS INSPECTION NOTES | |||
| ROOF VALLEY & METAL | 12/17/2024 | CANCELLED BY APPLICANT | FWILLIS |
| TIE BEAM / LINTEL | 12/09/2024 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 11/26/2024 | APPROVED | FWILLIS |
| Note: 11/25/2024 - PREVIOUS INSPECTION NOTES REBAR MISSING AS PER APPROVED DRAWINGS. DOWELS NOT INSTALLED AS PER APPROVED DRAWINGS. | |||
| MONOLITHIC SLAB | 11/25/2024 | Disapproved - NO FEE | FWILLIS |
| Note: REBAR MISSING AS PER APPROVED DRAWINGS. DOWELS NOT INSTALLED AS PER APPROVED DRAWINGS. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/15/2024 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 11/01/2024 | 11/06/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/01/2024 | 11/06/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/01/2024 | 11/07/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/01/2024 | 11/01/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/22/2024 | 10/25/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by AC contractor showing supply and return air for bedroom/ bathroom (Second Request) 2. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2023 8TH Edition 3. Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2023 8Th edition | |||
| ELEC | HOLD | 10/22/2024 | 10/28/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need outlet in bathroom next to sink. NEC 2020 210.52 (D) 2. Need smoke alarm inside of bedroom. FRC 2020 314 3. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4. 2nd REQUEST | |||
| BLD | HOLD | 10/22/2024 | 10/28/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Revise all general notes and engineering notes to show current code years. (Second Request) 2. Provide soffit dimensions on plans. 107.2.1 3. Provide soffit detail showing midpoint span if over than 12 inches 704.2.1-704.2.4 FBC Residential 2023 | |||
| ZON | COMPLETE | 10/22/2024 | 10/22/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/08/2024 | 10/14/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. Plans shall be in compliance with the current building codes and referenced standards. 2023 Florida Building Code, Residential , 8th Edition. 2. Needs soffit detail per FBC [A] 107.3 3. Needs EOR acceptance of truss engineering FBC [A] 107.3 | |||
| ELEC | HOLD | 10/08/2024 | 10/11/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need outlet in bathroom next to sink. NEC 2020 210.52 (D) 2. Need smoke alarm inside of bedroom. FRC 2020 314 3. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4. | |||
| ENGIN1 | COMPLETE | 10/08/2024 | 10/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 10/08/2024 | 10/09/2024 |
| MECH | HOLD | 10/08/2024 | 10/09/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calc needs to be for addition. Not total house. Heatlaod can be from total house. Revise energy calcs. Submit as one document except for state card. 2. Provide duct layout signed by AC contractor showing supply and return air for bedroom/ bathroom | |||
| PLUM | COMPLETE | 10/08/2024 | 10/14/2024 |
| Note: Released By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/08/2024 | 10/14/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | COMPLETE | 10/08/2024 | 10/08/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤45.36) | 11/09/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/09/2024 |
| INSPECTION - RESIDENTIAL | ¤330.00 | 11/09/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤93.60 | 11/09/2024 |
| SURCHARGE FS 533.721 | ¤4.08 | 11/09/2024 |
| SURCHARGE - FS 468.631 | ¤6.12 | 11/09/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 11/09/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/09/2024 |
| SITE PLAN 30 | ¤30.00 | 11/09/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤488.44 |