I want to search for...

Permit #2024100402

Permit Details

Status: COED

Parcel Id: 06-12-31-5180-00000-0390
CONDITIONED SPACE: 2115 sqft
GARAGE: 425 sqft
OPENED PORCH (WITH ROOF) : 335 sqft
Total Square Footage: 2875 sqft
Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1
Job Phone: 904-669-7000
Location Address: 40 MAHOGANY WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/18/2024
NOC: RECORDED
Applicant name: PAUL GILBERT AXTELL
Owner: TOLL SOUTHEAST LP CO INC

Address

1140 VIRGINIA DRIVE

FORT WASHINGTON, PA 19034

Lot: 39
Contracted Stated Job Value: ¤403,274.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

TOLL BROS INC
Status Location Address State License Number Phone
ACTIVE

40 EVEREST LN, STE 5

ST JOHNS, FL 32259

CGC60445 (Exp: 08/31/2026) 904-217-3852

Sub Contractors

JAMES F QUINN III
Status Location Address State License Number Phone
ACTIVE

3210 SW 40TH BLVD STE F

GAINESVILLE, FL 32608

EC13010994 (Exp: 08/31/2026) 352-378-9274
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700
JAMES MICHAEL WATSON
Status Location Address State License Number Phone
INACTIVE

38115 YALE CIRCLE

LEESBURG, FL 34748

SCC131152841 (Exp: 08/31/2026) 352-434-0115

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 04/23/2025 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
U -UTILITY RESIDENTIAL FINAL 04/16/2025 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 reclaim irr-no cc
ROW - FINAL APRON (AFTER POUR) 04/16/2025 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
BLD - BUILDING FINAL 04/16/2025 FINAL APPROVED MCONTRYMAN
ROW - STORMWATER FINAL 04/16/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/16/25 AS NOTED IN PREVIOUS INSPECTION ** 04/14/25 WILL NEED TO INSTALL A COURSE OF SOD ON BACK SIDE OF SILT FENCE ALONG BOTH LEFT / RIGHT SIDE PROPERTY LINES UP TO THE BACK OF CURB AND GUTTER TO PREVENT WASHOUTS FROM GUTTERS . _____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 ** 04/14/25 WILL NEED TO INSTALL A COURSE OF SOD ON BACK SIDE OF SILT FENCE ALONG BOTH LEFT / RIGHT SIDE PROPERTY LINES UP TO THE BACK OF CURB AND GUTTER TO PREVENT WASHOUTS FROM GUTTERS . ** NEED TO REMOVE FORM BOARDS FROM SIDEWALK SLAB BE FORE FINALS AND ENSURE SOD AROUND THE END OF SDEWALK ______________________________________________________________________________________________________________________ ** 04/07/25 LEFT SIDE OF DRIVEWAY SIDEWALK SLAB WAS NOT POURED WITH THE DRIVEWAY ** BOTH THE LEFT AD RIGHT SIDE REAR CORNERS NEED TO FINISH SOD AT PROPERTY LINE AND COMMON AREA ** BOTH RIGHT AND LEFT SIDE NEED SILT FENCE INSTALLED ALONG PROPERTY LINE I
ROW FIELD SURVEY /GRADING CERTIFICATION 04/14/2025 APPROVED - AS NOTED EMADISON
Note: ** 04/14/25 WILL NEED TO INSTALL A COURSE OF SOD ON BACK SIDE OF SILT FENCE ALONG BOTH LEFT / RIGHT SIDE PROPERTY LINES UP TO THE BACK OF CURB AND GUTTER TO PREVENT WASHOUTS FROM GUTTERS . ** NEED TO REMOVE FORM BOARDS FROM SIDEWALK SLAB BE FORE FINALS AND ENSURE SOD AROUND THE END OF SDEWALK ______________________________________________________________________________________________________________________ ** 04/07/25 LEFT SIDE OF DRIVEWAY SIDEWALK SLAB WAS NOT POURED WITH THE DRIVEWAY ** BOTH THE LEFT AD RIGHT SIDE REAR CORNERS NEED TO FINISH SOD AT PROPERTY LINE AND COMMON AREA ** BOTH RIGHT AND LEFT SIDE NEED SILT FENCE INSTALLED ALONG PROPERTY LINE I
ROW- PRE-APRON (PRE-POUR) 04/10/2025 APPROVED - AS NOTED EMADISON
Note: ** 04/10/25 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE *** THIS PRWE-POUR INSPECTION IS FOR THE LAST SECTION OF SIDEWALK ON THE LEFT SIDE ADJOINING WITH THE DRIVEWAY *** DO NOT USE ANY EXPANSION JOINT MATERIAL BETWEEN SIDEWALK AND DRIVEWAY*** USE A BONDING AGENT WITH THIS POUR AT THE EXISTING EDGE OF DRIVEWAY
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/07/2025 APPROVED EMADISON
Note: 4/3/2025 - PREVIOUS INSPECTION NOTES ALL ELEVATIONS AGAINST THE STRUCTURE NEEDS TO BE 6" BELOW FFE OF THE HOUSE. FLORIDA BUILDING CODE Chapter 4, R404.1.6- Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/07/2025 Disapproved - NO FEE EMADISON
Note: ** 04/07/25 LEFT SIDE OF DRIVEWAY SIDEWALK SLAB WAS NOT POURED WITH THE DRIVEWAY ** BOTH THE LEFT AD RIGHT SIDE REAR CORNERS NEED TO FINISH SOD AT PROPERTY LINE AND COMMON AREA ** BOTH RIGHT AND LEFT SIDE NEED SILT FENCE INSTALLED ALONG PROPERTY LINE I
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/03/2025 Disapproved - NO FEE PFLANAGAN
Note: ALL ELEVATIONS AGAINST THE STRUCTURE NEEDS TO BE 6" BELOW FFE OF THE HOUSE. FLORIDA BUILDING CODE Chapter 4, R404.1.6- Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures.
U-CROSS CONNECTION 04/02/2025 APPROVED - AS NOTED LFITZGERALD
Note: reclaim irr-no cc
ELECTRIC - EARLY POWER 03/25/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 3/25/25 Okay to release e-mail to FPL 1. ODU does not match energy calcs (breakers are okay) FBC(A) 107.4 --moving forward, energy calcs are required at all early power inspections--
ELECTRIC-TUG 03/11/2025 APPROVED CVANSTRAHLEN
ELECTRIC-TUG 03/05/2025 Disapproved - NO FEE MCONTRYMAN
Note: 3/5/25 1. Please secure conduit for service wire (missing bracket) NEC 352.3 2. Please secure GFCI outlet to building and tighten line to panel 3. Install surge protection at meter/main only NEC 230.67
ROW- PRE-APRON (PRE-POUR) 02/25/2025 APPROVED FSLADISH
Note: 2/25/25 READY TO POUR AT THE TIME OF THIS INSPECTION. . BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE CONCRETE IS 3000 PSI BUILDER RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
GRAVITY SEWER TEST 01/08/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 01/08/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 01/03/2025 APPROVED RSIMS
Note: 1/2/2025 - PREVIOUS INSPECTION NOTES 1/2/25: NOTE: Solid wood over SGD is good. Please foam perimeter. 1). Missing firestop at top plate area above breaker panel in garage. Stud below marked with FS. 2). Missing firestop at top plate penetration for pest control lines in right side bathroom and in left side bedrooms along with left back wall. Stud below marked with FS. 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/2024 Not Ready. Installers on site. Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders. Inspector Notes from Inspection 2420 12/26/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders.
INSULATION 01/02/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/2/2025 10:48:32 AM *** 1/2/25: NOTE: Solid wood over SGD is good. Please foam perimeter. 1). Missing firestop at top plate area above breaker panel in garage. Stud below marked with FS. 2). Missing firestop at top plate penetration for pest control lines in right side bathroom and in left side bedrooms along with left back wall. Stud below marked with FS. 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/2024 Not Ready. Installers on site. Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders. Inspector Notes from Inspection 2420 12/26/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders.
INSULATION 12/30/2024 Disapproved - NO FEE PKNAPIK
Note: 12/30/2024 Not Ready. Installers on site. Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders. Inspector Notes from Inspection 2420 12/26/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders.
LATH/BRICK/ WATER BARRIER 12/30/2024 APPROVED - AS NOTED PKNAPIK
Note: 12/30/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders. Inspector Notes from Inspection 2420 12/26/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders.
ALL ROUGH 12/26/2024 APPROVED - AS NOTED PKNAPIK
Note: 12/26/2024 Check at insulation. 1. Gap above Sliders too big. Please fill with wood. FBCR 609.1 2. FL approval, u-factor, and SHGC missing on sliders.
LATH/BRICK/ WATER BARRIER 12/26/2024 Disapproved - NO FEE PKNAPIK
Note: 12/26/2024 1. Left side of slider, edge needs to be taped.
ROOF VALLEY & METAL 12/13/2024 APPROVED PKNAPIK
Note: 12/9/2024 - PREVIOUS INSPECTION NOTES Not ready.
ROOF VALLEY & METAL 12/09/2024 Disapproved - NO FEE PKNAPIK
Note: Not ready.
WALL SHEATHING 12/03/2024 APPROVED PKNAPIK
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/03/2024 APPROVED - AS NOTED PKNAPIK
Note: 12/3/2024 Check at next inspection 1. (3) 2x6 post - one cut at bottom for dtt2z. need to add another to other side - marked on plans.
WATER METER INSTALLATION REQUEST 11/26/2024 APPROVED CBOWERMASTER
FOUND SURVEY APPROVED (OFFICE) 11/25/2024 APPROVED JMYERS
MONOLITHIC SLAB 11/07/2024 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 11/06/2024 APPROVED MGIBSON
Note: 11/5/2024 - PREVIOUS INSPECTION NOTES 11/4/2024 - PREVIOUS INSPECTION NOTES FBCR-P-2504.5 HEAD TEST. NOT RESOLVED
PLUMBING 1ST ROUGH UNDERGROUND 11/05/2024 Disapproved -FEE REQUIRED MGIBSON
Note: 11/4/2024 - PREVIOUS INSPECTION NOTES FBCR-P-2504.5 HEAD TEST. NOT RESOLVED
PLUMBING 1ST ROUGH UNDERGROUND 11/04/2024 Disapproved -FEE REQUIRED MGIBSON
Note: FBCR-P-2504.5 HEAD TEST

Review History

Department Status Date In Date Out
MECH COMPLETE 03/31/2025 04/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/14/2025 01/17/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/12/2024 12/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/10/2024 12/11/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/25/2024 12/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/18/2024 11/21/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/18/2024 11/25/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/18/2024 11/18/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 10/11/2024 10/17/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/11/2024 10/15/2024
Note: Released By: JPI
CUSVC COMPLETE 10/11/2024 10/14/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Water/Sewer impact fees will be added at a later date after all utility agreements are final. Please note, meter will not be installed until all agreements complete and fees paid.
ELEC COMPLETE 10/11/2024 10/14/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/11/2024 10/15/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS COMPLETE 10/11/2024 10/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 10/11/2024 10/16/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 10/11/2024 10/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/11/2024 10/14/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 10/11/2024 10/11/2024
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
URB COMPLETE 10/11/2024 10/18/2024
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 04/17/2025
CONTRACTOR CHANGE ¤20.00 03/06/2025
REINSPECTION RESIDENTIAL ¤40.00 11/08/2024
REINSPECTION RESIDENTIAL ¤40.00 11/08/2024
CONNECTION FEES ¤25.00 10/18/2024
FC IMPACT FEE EMS ¤62.00 10/18/2024
IMPACT FEE FIRE ¤434.51 10/18/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/18/2024
FC IMPACT FEE LIBRARY ¤268.00 10/18/2024
IMPACT FEE PARKS ¤1,828.01 10/18/2024
IMPACT FEE SCHOOL ¤5,450.00 10/18/2024
IMPACT FEE TRANSPORTATION ¤2,638.00 10/18/2024
SURCHARGE FS 533.721 ¤13.11 10/18/2024
SURCHARGE - FS 468.631 ¤19.66 10/18/2024
SW ENG - FOUNDATION SURVEY ¤20.00 10/18/2024
SW ENG INSPECTION 80 ¤80.00 10/18/2024
SW ENG PRE APRON ¤30.00 10/18/2024
SW ENG - REVIEW 20 ¤20.00 10/18/2024
SW ENG RES REVIEW 200 ¤200.00 10/18/2024
SEWER INSPECTION ¤25.00 10/18/2024
SITE PLAN 30 ¤30.00 10/18/2024
WATER-METER ¤514.49 10/18/2024
WATER-METER ¤427.42 10/18/2024
ADJUSTMENT 10% (¤145.61) 10/18/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/18/2024
INSPECTION - RESIDENTIAL ¤1,111.00 10/18/2024
PLAN REVIEW - RESIDENTIAL ¤315.12 10/18/2024
Fees Total Due: ¤0.00 Total Paid: ¤13,733.71