Permit #2024100514
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00380-0080 |
| Block: 00380 |
| Subdivision: - |
| Job Phone: 508-685-5863 |
| Location Address: 15 PICKSTON LN |
| Type: EL - ELECTRICAL |
| Issue Date: 04/08/2025 |
| NOC: Unknown |
| Applicant name: COREY E PRICE |
| Owner: RAY, CHARLES LOGAN & ERICA ANN |
|
Address 15 PICKSTON LANE PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤2,000.00 |
| Job Description: REPLACE PANEL 150AMP |
| Type: CN |
Contractor
MISTER SPARKY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11290 ST JOHNS INDUSTRIAL PKWY N #7 JACKSONVILLE, FL 32246 |
ER13015630 (Exp: 08/31/2026) | 904-222-2121 | 904-222-8891 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 06/05/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/5/2025 12:07:22 PM *** 5/15/2025 - PREVIOUS INSPECTION NOTES 5/15/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). _____ 1). Newly installed LFMC installed to well pump needs to be secured to the wall and re-run in a manner that protects it from damage as required. --- >>> NEC 300.4 - Protection Against Physical Damage: Where subject to physical damage, conductors, raceways, and cables shall be protected. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4 | |||
| ELECTRIC FINAL | 05/15/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/15/2025 11:43:56 AM *** 5/15/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). _____ 1). Newly installed LFMC installed to well pump needs to be secured to the wall and re-run in a manner that protects it from damage as required. --- >>> NEC 300.4 - Protection Against Physical Damage: Where subject to physical damage, conductors, raceways, and cables shall be protected. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4 | |||
| ELECTRIC FINAL | 04/09/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/9/2025 10:20:23 AM *** 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4 |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 10/24/2024 | 10/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 10/14/2024 | 10/15/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/04/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/14/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/08/2025 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/08/2025 |
| ADJUSTMENT 10% | (¤12.25) | 04/08/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/08/2025 |
| INSPECTION- ELECTRICAL | ¤60.00 | 04/08/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 04/08/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤194.25 |