Permit Details

Status: FINAL

Parcel Id: 07-11-31-7026-00380-0080
Block: 00380
Subdivision: -
Job Phone: 508-685-5863
Location Address: 15 PICKSTON LN
Type: EL - ELECTRICAL
Issue Date: 04/08/2025
NOC: Unknown
Applicant name: COREY E PRICE
Owner: RAY, CHARLES LOGAN & ERICA ANN

Address

15 PICKSTON LANE

PALM COAST, FL 32164

Lot: 0080
Contracted Stated Job Value: ¤2,000.00
Job Description: REPLACE PANEL 150AMP
Type: CN

Contractor

MISTER SPARKY
Status Location Address State License Number Phone Fax
INACTIVE

11290 ST JOHNS INDUSTRIAL PKWY N #7

JACKSONVILLE, FL 32246

ER13015630 (Exp: 08/31/2026) 904-222-2121 904-222-8891

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 06/05/2025 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/5/2025 12:07:22 PM *** 5/15/2025 - PREVIOUS INSPECTION NOTES 5/15/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). _____ 1). Newly installed LFMC installed to well pump needs to be secured to the wall and re-run in a manner that protects it from damage as required. --- >>> NEC 300.4 - Protection Against Physical Damage: Where subject to physical damage, conductors, raceways, and cables shall be protected. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4
ELECTRIC FINAL 05/15/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/15/2025 11:43:56 AM *** 5/15/25: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). _____ 1). Newly installed LFMC installed to well pump needs to be secured to the wall and re-run in a manner that protects it from damage as required. --- >>> NEC 300.4 - Protection Against Physical Damage: Where subject to physical damage, conductors, raceways, and cables shall be protected. 4/9/2025 - PREVIOUS INSPECTION NOTES 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4
ELECTRIC FINAL 04/09/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2025 10:20:23 AM *** 4/9/25: 1). Surge protector needs to be located on the buss bar at the point of power entry. (very first spots on buss bar) per Manufacturer and NEC-230.67(A)/(B) 2). LFMC feed for well pump: feed needs to be safed off properly 2020 NEC 110.27 and LFMC raceway needs to be securerly fastened within 12" of junction box. 3). Hole in ceiling where LFMC enters attic space needs to be sealed with approved material. FBC-302.11.4

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/24/2024 10/24/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 10/14/2024 10/15/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/04/2025
REINSPECTION RESIDENTIAL ¤40.00 05/14/2025
SURCHARGE FS 533.721 ¤2.00 04/08/2025
SURCHARGE - FS 468.631 ¤2.00 04/08/2025
ADJUSTMENT 10% (¤12.25) 04/08/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/08/2025
INSPECTION- ELECTRICAL ¤60.00 04/08/2025
PLAN REVIEW - MISC 32.50 ¤32.50 04/08/2025
Fees Total Due: ¤0.00 Total Paid: ¤194.25