I want to search for...
Permit #2024100718
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7035-00480-0020 |
| Block: 00480 |
| Subdivision: 7035 - |
| Job Phone: 386-216-9945 |
| Location Address: 33 BUNKER KNOLLS LN |
| Type: PO - POOL |
| Issue Date: 11/07/2024 |
| NOC: RECORDED |
| Applicant name: CASEY C WATSON |
| Owner: KOSHELEV ANTON & INNA H&W & THOMAS F ZIEGLER JTWRO |
|
Address 33 BUNKER KNOLLS LANE PALM COAST, FL 32137 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤87,658.00 |
| Job Description: POOL WITH SCREEN |
| Type: CN |
Contractor
EXQUISITE POOL & SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3895 BRITTING DR DELAND, FL 32724 |
CPC1457932 (Exp: 08/31/2026) | 386-216-9945 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
JOHN LEROY HODGINS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2020 COUNTRY FARMS RD PORT ORANGE, FL 32128 |
CGC1507254 (Exp: 08/31/2026) | 386-547-2998 | 386-788-4028 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 05/08/2025 | FINAL APPROVED | JSTEWART |
| U -UTILITY RESIDENTIAL FINAL | 04/30/2025 | FINAL APPROVED | DHANEY |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/29/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/24/2025 - PREVIOUS INSPECTION NOTES 04/24/25 TPOLACEK*** UPON WALKING THE PROPERTY WITH HOMEOWNER FOUND THE DRAINAGE PATTERN CREATED WILL NOT ALLOW DRAINAGE TO REACH THE FRONT SWALE. IN THE AREA THE CONTRACTOR DUG UP AND LOWERED THE REAR IS OK BUT WHERE IT ENDS ALONG LEFT SIDE IT STOPS TOO SOON. CONTRACTOR MUST CONTINUE TO DIG SWALE AROUND TO AT LEAST THE CORNER LINE OF STRUCTURE. I HAVE EXPLAINED TO HOME OWNER SO SHE IS AWARE OF THE AREA IN QUESTION. AS A NOTE THE LEFT SIDE PROPERTY LINE ALONG VACANT LOT MUST HAVE SEED AND STRAW ON ALL BARE GROUND DISTURBED DURING CONSTRUCTION. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." Lot Grading Permit Requirements (Improved Properties) Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage | |||
| ROW - FINAL INSPECTION | 04/29/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/24/2025 | APPROVED | TPOLACEK |
| Note: 3/27/2025 - PREVIOUS INSPECTION NOTES 03/27/25 TPOLACEK*** FINAL SURVEY INDICATES DRAINAGE IN REAR OF POOL DECK WILL NEGATIVELY IMPACT ADJOINING PROPERTY TO THE REAR. SEE ATTACHED PHOTO. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/24/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/24/25 TPOLACEK*** UPON WALKING THE PROPERTY WITH HOMEOWNER FOUND THE DRAINAGE PATTERN CREATED WILL NOT ALLOW DRAINAGE TO REACH THE FRONT SWALE. IN THE AREA THE CONTRACTOR DUG UP AND LOWERED THE REAR IS OK BUT WHERE IT ENDS ALONG LEFT SIDE IT STOPS TOO SOON. CONTRACTOR MUST CONTINUE TO DIG SWALE AROUND TO AT LEAST THE CORNER LINE OF STRUCTURE. I HAVE EXPLAINED TO HOME OWNER SO SHE IS AWARE OF THE AREA IN QUESTION. AS A NOTE THE LEFT SIDE PROPERTY LINE ALONG VACANT LOT MUST HAVE SEED AND STRAW ON ALL BARE GROUND DISTURBED DURING CONSTRUCTION. 7 Rear Yard Drainage Sec 300.01(4,5,6) "Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet." Lot Grading Permit Requirements (Improved Properties) Sec 300.03 F4-A / V-22 Sec 300.03 F4-The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion. Bare earth and damage to any City roadside swales, drainage ditches, canals or other drainage conveyances must be graded to the proper elevation and sodded to prevent soil erosion. Road damage in the area of construction is also attributable to the Permittee, unless a preconstruction inspection has previously documented the damage | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/27/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 03/27/25 TPOLACEK*** FINAL SURVEY INDICATES DRAINAGE IN REAR OF POOL DECK WILL NEGATIVELY IMPACT ADJOINING PROPERTY TO THE REAR. SEE ATTACHED PHOTO. Finished Floor Elevations (FFE):REAR YARD DRAINAGE Section 300.01 D(6) V-17 6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ELECTRIC AND ALARM | 02/26/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 2/26/2025 3:13:52 PM *** Pool heater requires GFCI Protection... 2020 NEC 680.21(C) / FBCR R4501.16 Please change prior to final inspection. | |||
| POOL DECK | 01/03/2025 | APPROVED | FWILLIS |
| STEEL AND GROUND | 11/19/2024 | APPROVED | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 11/04/2024 | 11/05/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/04/2024 | 11/07/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/30/2024 | 10/30/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Screen plan dimensions do not match revised site plan | |||
| ENGIN1 | COMPLETE | 10/30/2024 | 10/31/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/30/2024 | 11/04/2024 |
| Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/28/2024 | 10/28/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Pool deck doesn't meet the minimum 10ft rear setback | |||
| BLD | COMPLETE | 10/17/2024 | 10/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/17/2024 | 10/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/17/2024 | 10/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/17/2024 | 10/22/2024 |
| Note: Released By: TOM POLACEK - (386)346-8986 - | |||
| ZON | HOLD | 10/17/2024 | 10/17/2024 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM There is a final survey available online for this survey from when the house was completed. The final survey shows that the house is closer to the rear property line than the proposed site plan you submitted. The pool deck and screen that you are proposing will not meet the minimum required 10' rear setback. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤25.86) | 11/07/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/07/2024 |
| INSPECTION- POOL | ¤160.00 | 11/07/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤68.64 | 11/07/2024 |
| SURCHARGE FS 533.721 | ¤2.33 | 11/07/2024 |
| SURCHARGE - FS 468.631 | ¤3.49 | 11/07/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 11/07/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/07/2024 |
| SITE PLAN 30 | ¤30.00 | 11/07/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤328.60 |