I want to search for...
Permit #2024101006
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00630-0180 |
| CONDITIONED SPACE: 1800 sqft |
| GARAGE: 410 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 2246 sqft |
| Block: 00630 |
| Subdivision: 7026 - |
| Job Phone: 689-250-2429 |
| Location Address: 3 PINTO LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/13/2024 |
| NOC: RECORDED |
| Applicant name: RYAN M COURECH |
| Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC |
|
Address 688 N ORLANDO AVENUE MAITLAND, FL 32751 |
|
Address 207 MAITLAND, FL 32751 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Original Permit #: 2024010999 |
Contractor
MCH CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
668 N ORLANDO AVE, STE 207 MAITLAND, FL 32751 |
CBC1262898 (Exp: 08/31/2026) | 407-602-8257 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
DUSTIN ARCHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2785 WRIGHTS ROAD SUITE 1133 OVIEDO, FL 32765 |
CMC1251099 (Exp: 08/31/2026) | 407-391-1145 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 09/02/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9272 08/28/25 TPOLACEK**** HOT PATCH IS NOT COMPLETED AT THIS TIME. BUILDER HAS NOT REQUESTED THE FINAL ROW SO I WILL APPROVE THE AFTER POUR AS NOTED AND WAIT FOR FINAL ROW FOR HOT PATCH. CULVERT IS FILLED WITH WATER AT THIS TIME AS WELL SO AT THE TIME OF FINAL ROW INSPECTOR SHALL CHECK CULVERT IS CLEAR OF DEBRIS AND OVER POUR CONCRETE. | |||
| ROW - FINAL APRON (AFTER POUR) | 08/28/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 08/28/25 TPOLACEK**** HOT PATCH IS NOT COMPLETED AT THIS TIME. BUILDER HAS NOT REQUESTED THE FINAL ROW SO I WILL APPROVE THE AFTER POUR AS NOTED AND WAIT FOR FINAL ROW FOR HOT PATCH. CULVERT IS FILLED WITH WATER AT THIS TIME AS WELL SO AT THE TIME OF FINAL ROW INSPECTOR SHALL CHECK CULVERT IS CLEAR OF DEBRIS AND OVER POUR CONCRETE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/27/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/27/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 08/25/2025 | Approval - Private Provider | PPROVIDER |
| ROW- PRE-APRON (PRE-POUR) | 07/30/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| U - SEWER TIE IN | 07/15/2025 | APPROVED | MGIBSON |
| U-CROSS CONNECTION | 07/15/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: noirr-no cc | |||
| GRAVITY SEWER TEST | 07/15/2025 | Approval - Private Provider | PPROVIDER |
| PEP TANK INSTALLATION REQUEST | 06/13/2025 | APPROVED | CBOWERMASTER |
| WALL SHEATHING | 05/30/2025 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/30/2025 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 05/28/2025 | Approval - Private Provider | PPROVIDER |
| INSULATION | 05/28/2025 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 05/28/2025 | Approval - Private Provider | PPROVIDER |
| ELECTRIC - EARLY POWER | 05/13/2025 | Approval - Private Provider | PPROVIDER |
| GRAVITY SEWER TEST | 04/29/2025 | CANCELLED BY APPLICANT | WEB |
| U-CROSS CONNECTION | 04/29/2025 | CANCELLED BY APPLICANT | WEB |
| U - SEWER TIE IN | 04/29/2025 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 04/23/2025 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 04/22/2025 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 04/21/2025 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 04/21/2025 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 02/06/2025 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 01/21/2025 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/08/2025 | Approval - Private Provider | PPROVIDER |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 01/06/2025 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 11/27/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 08/28/2025 | 08/28/2025 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 08/27/2025 | 08/27/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No inspection codes provided | |||
| MECH | COMPLETE | 08/06/2025 | 08/06/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/13/2025 | 06/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/28/2025 | 05/28/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM wrong code on the inspecton report for a lintel | |||
| BADMIN | INFORMATION | 04/21/2025 | 04/21/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| ENGIN1 | COMPLETE | 02/06/2025 | 02/06/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/06/2025 | 02/06/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/30/2024 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/20/2024 | 12/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/16/2024 | 12/19/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This was deferred submittal of geotech. Submit preliminary report | |||
| BLD | HOLD | 12/09/2024 | 12/13/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit certification letter and density reports. Must be digitally signed and sealed. | |||
| BLD | COMPLETE | 11/05/2024 | 11/13/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 10/29/2024 | 11/05/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/29/2024 | 11/05/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 2. product approval sheet is not filled out completely. 3. Need to update revision numbers. | |||
| LOCATE | COMPLETE | 10/23/2024 | 10/29/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/23/2024 | 10/23/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | COMPLETE | 10/23/2024 | 10/25/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/23/2024 | 10/29/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 10/23/2024 | 10/29/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need shop drawing approval stamp on truss packet or truss layout. 2. product approval sheet is not filled out completely. 3. Need to update revision numbers. 4. Submit truss layout | |||
| CUSVC | COMPLETE | 10/23/2024 | 10/24/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/23/2024 | 10/23/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 10/23/2024 | 10/23/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For future private provider submittals. The owner name on the priviate provider forms need to match the legal owners name in every area where the owner is identified. Example, A and R Meridian .... is the owner. Not MCH or other names that were entered in as owners in the 'fee owner' name area and signature owner name area. The certificate of insurance from the private provider should have the City of Palm Coast lsited as the certificate holder. Certificates holders are notified if there is a lapse in insurance. | |||
| SWALE | COMPLETE | 10/23/2024 | 12/06/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 09/02/2025 |
| CONNECTION FEES | ¤1,187.26 | 11/13/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 11/13/2024 |
| IMPACT FEE FIRE | ¤434.51 | 11/13/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 11/13/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 11/13/2024 |
| IMPACT FEE PARKS | ¤1,828.01 | 11/13/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 11/13/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 11/13/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/13/2024 |
| SURCHARGE FS 533.721 | ¤3.43 | 11/13/2024 |
| SURCHARGE - FS 468.631 | ¤5.14 | 11/13/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/13/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/13/2024 |
| SW ENG PRE APRON | ¤30.00 | 11/13/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/13/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/13/2024 |
| SEWER CREDIT | (¤2,089.25) | 11/13/2024 |
| SEWER INSPECTION | ¤25.00 | 11/13/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 11/13/2024 |
| WATER CREDIT | (¤620.28) | 11/13/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 11/13/2024 |
| SITE PLAN 30 | ¤30.00 | 11/13/2024 |
| WATER- TURN ON | ¤25.00 | 11/13/2024 |
| ADJUSTMENT 50% | (¤342.60) | 11/13/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/13/2024 |
| INSPECTION - RESIDENTIAL | ¤572.00 | 11/13/2024 |
| PLAN REVIEW - APPROVED MASTER | ¤83.20 | 11/13/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,910.58 |