Permit #2024101111

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7035-01620-0170
Block: 01620
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 904-750-3404
Location Address: 77 BIRCHWOOD DR
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 10/28/2024
NOC: RECORDED
Applicant name: PATRICK ANTHONY PIZZULO
Owner: WILLIAMS LAKISHA

Address

77 BIRCHWOOD DRIVE

PALM COAST, FL 32137

Lot: 0170
Contracted Stated Job Value: ¤11,493.78
Job Description: REPLACE INSULATION AND DRYWALL DUE TO FIRE DAMAGE REF 2023101312
Type: CN
Original Permit #: 2023101312

Contractor

ONERESTORE, LLC
Status Location Address State License Number Phone
ACTIVE

1540 SW 5TH AVE, SUITE 101

SAINT AUGUSTINE, FL 32084

CRC1326353 (Exp: 08/31/2026) 904-750-3404

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/14/2025 Disapproved - NO FEE JSTEWART
Note: LIFE SAFTEY....Bathroom at master bedroom, receptacle at vanity requires gfci Protection. Note: GFCI Receptacle is installed but is not functioning to test, does not trip). at time of restoration all receptacles and lights were removed and new installed. Please make repair and reschedule for re inspection. 1/27/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/27/2025 1:56:38 PM *** 1. Knocked at door twice No answer. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS 2. Electric Permit is expired, and requires a final inspection approval. Since electric work was part of the restoration. Please obtain a re issued permit.
BLD - BUILDING FINAL 01/27/2025 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 1/27/2025 1:56:38 PM *** 1. Knocked at door twice No answer. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS 2. Electric Permit is expired, and requires a final inspection approval. Since electric work was part of the restoration. Please obtain a re issued permit.
INSULATION 01/21/2025 CANCELLED BY APPLICANT WEB
Note: 11/22/2024 - PREVIOUS INSPECTION NOTES 11/22/24 - Could not verify correct amount of insulation in the attic. Please provide access to this area. Masterbedroom area, could not verify Insulation in the walls, Area is covered. Sheetrock must be removed to verify Insulation in this wall. Side Note: People are actively living here so DoNot use the key in the lock box to enter.
INSULATION 01/17/2025 APPROVED FWILLIS
Note: 1/17/25 - INSULATION HAS BEEN INSTALLED IN THE GARAGE WALL SEPARATING GARAGE AND MASTER BEDROOM, ONLY. New inspection due to canceled inspection 11/22/2024 - PREVIOUS INSPECTION NOTES 11/22/24 - Could not verify correct amount of insulation in the attic. Please provide access to this area. Masterbedroom area, could not verify Insulation in the walls, Area is covered. Sheetrock must be removed to verify Insulation in this wall. Side Note: People are actively living here so DoNot use the key in the lock box to enter.
INSULATION 11/22/2024 Disapproved -FEE REQUIRED FWILLIS
Note: 11/22/24 - Could not verify correct amount of insulation in the attic. Please provide access to this area. Masterbedroom area, could not verify Insulation in the walls, Area is covered. Sheetrock must be removed to verify Insulation in this wall. Side Note: People are actively living here so DoNot use the key in the lock box to enter.
BLD - BUILDING FINAL
Note: 7/14/2025 - PREVIOUS INSPECTION NOTES LIFE SAFTEY....Bathroom at master bedroom, receptacle at vanity requires gfci Protection. Note: GFCI Receptacle is installed but is not functioning to test, does not trip). at time of restoration all receptacles and lights were removed and new installed. Please make repair and reschedule for re inspection. 1/27/2025 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 1/27/2025 1:56:38 PM *** 1. Knocked at door twice No answer. FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS 2. Electric Permit is expired, and requires a final inspection approval. Since electric work was part of the restoration. Please obtain a re issued permit.

Review History

Department Status Date In Date Out
BLD COMPLETE 11/02/2023 11/03/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 11/01/2023 11/02/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide insulation value to be installed. The R value not dollar amount.
ZON COMPLETE 10/30/2023 10/30/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD HOLD 10/29/2023 10/31/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide insulation value to be installed. 2. Fire was in Master bedroom area is this where you are repairing?
ELEC CANCEL 10/29/2023 10/31/2023
MECH CANCEL 10/29/2023 10/31/2023
PLUM CANCEL 10/29/2023 10/31/2023

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - EXTENSION ¤40.00 07/23/2025
REINSPECTION RESIDENTIAL ¤40.00 12/06/2024
SURCHARGE FS 533.721 ¤2.00 10/28/2024
SURCHARGE - FS 468.631 ¤2.00 10/28/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/28/2024
INSPECTION - RESIDENTIAL ¤60.00 10/28/2024
ADJUSTMENT 10% (¤9.00) 10/28/2024
Fees Total Due: ¤0.00 Total Paid: ¤165.00