I want to search for...
Permit #2024101233
Permit Details
Status: COED
| Parcel Id: 03-12-31-1125-00000-R010 |
| Block: 01010 |
| Subdivision: 2112 - COLBERT LANDINGS PH 1 |
| Job Phone: 904-294-2220 |
| Location Address: 5 ARMOYAN DR |
| Type: CPO - COMMERCIAL POOL |
| Issue Date: 12/20/2024 |
| NOC: RECORDED |
| Applicant name: JUDSON CLARKSON |
| Owner: MERITAGE HOMES OF FLORIDA INC |
|
Address 8800 E RAINTREE DRIVE SCOTTSDALE, AZ 85260 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤309,472.00 |
| Job Description: SWIMMING POOL - COLBERT LANDING |
| Type: CN |
Contractor
POOLS BY JOHN CLARKSON INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
600 ST JOHNS RD N , |
CPC1459376 (Exp: 08/31/2026) | 904-294-2220 |
Sub Contractors
DAVID THOMAS PRUETTE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
331-8 PARKRIDGE AVE ORANGE PARK , FL 32065 |
EC0002923 (Exp: 08/31/2026) | 904-272-7225 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC- LANDSCAPE FINAL | 07/21/2025 | APPROVED | RPICATAGI |
| Note: 7/8/2025 2:15:01 PM- PREVIOUS INSPECTION NOTES Two Items require screening with 30" ht shrubs near the west entrance (closest to building) 1. Backflow preventer piping 2. Large white utility box must leave min 36" clearance from utility box and screen planting must block view from roadway and entrance road. Screening is not required at the back side of the white utility box | |||
| POOL CERTIFICATION/ OPERATING PERMIT - STATE DOH | 07/17/2025 | APPROVED | JMUNSON |
| BUILDING POOL FINAL | 07/11/2025 | FINAL APPROVED | KSANDOE |
| FIRE FINAL | 07/08/2025 | APPROVED | RMARTIN |
| LDSC- LANDSCAPE FINAL | 07/08/2025 | Disapproved - NO FEE | RPICATAGI |
| Note: Two Items require screening with 30" ht shrubs near the west entrance (closest to building) 1. Backflow preventer piping 2. Large white utility box must leave min 36" clearance from utility box and screen planting must block view from roadway and entrance road. Screening is not required at the back side of the white utility box | |||
| ELECTRIC FINAL | 06/24/2025 | APPROVED | RMARTIN |
| Note: 6/20/2025 - PREVIOUS INSPECTION NOTES 1. No pool electrical plans on site. FBC 107.3.1 2. Fence around pool equipment must be bonded NEC 680.26 3. Pool panel does not have 3' of working clearence NEC 110.26 | |||
| PLUMBING FINAL | 06/20/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 6/20/2025 9:59:33 AM *** This inspection is for the pool and pool equipment only. Related permit for the Amenity Center (2024070081) will cover any building related items including right front side cleanout needs to be flush with final grade. | |||
| ELECTRIC FINAL | 06/20/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. No pool electrical plans on site. FBC 107.3.1 2. Fence around pool equipment must be bonded NEC 680.26 3. Pool panel does not have 3' of working clearence NEC 110.26 | |||
| POOL SAFETY | 06/11/2025 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 3590 Must add electrical inspection for bonding of deck and handrails. Expose connections | |||
| POOL DECK | 06/05/2025 | APPROVED - AS NOTED | KSANDOE |
| Note: Must add electrical inspection for bonding of deck and handrails. Expose connections | |||
| ELECTRIC 1ST ROUGH | 05/08/2025 | APPROVED | JMUNSON |
| Note: 5/7/2025 - PREVIOUS INSPECTION NOTES Need equal potential bonding around pool deck nec 680.26 | |||
| ELECTRIC 1ST ROUGH | 05/07/2025 | Disapproved - NO FEE | RMARTIN |
| Note: Need equal potential bonding around pool deck nec 680.26 | |||
| PLUMBING 2ND ROUGH | 04/02/2025 | APPROVED | MGIBSON |
| Note: 3/31/2025 - PREVIOUS INSPECTION NOTES | |||
| PLUMBING 2ND ROUGH | 03/31/2025 | CANCELLED BY APPLICANT | MGIBSON |
| PLUMBING 2ND ROUGH | 03/28/2025 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH | 03/07/2025 | APPROVED | MGIBSON |
| POOL STEEL AND GROUND | 03/07/2025 | APPROVED | HCAMACHO |
Review History
| Department | Status | Date In | Date Out |
| DSD | COMPLETE | 12/09/2024 | 12/20/2024 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/09/2024 | 12/20/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 12/09/2024 | 12/20/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/28/2024 | 11/12/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-BUILDING AND FLORIDA BUILDING CODE-ACCESSIBILITY PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. 1. Per FBC 454.1.2.5.6 Disabled access. ADA requirement for newly constructed commercial pool. 2. Per FBCA 206, 207, 402, 403, 404, Please show maneuverability at access gates (show route dimensions, slope, cross slope, maneuverable spaces at push and pull side of latches). 3. Note indicates deck slope 2% for 1st 4 feet around pool. Per FCBA 305 please show deck slope requirement for accessibility for the remainder of the deck. | |||
| DSD | HOLD | 10/28/2024 | 11/04/2024 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Need to apply for fence permit or provide fence details color material and a color elevation of the commercial fence and gate for the pool area. | |||
| ELEC | COMPLETE | 10/28/2024 | 11/08/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/28/2024 | 11/08/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 10/28/2024 | 11/12/2024 |
| Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-PLUMBING AND FLORIDA BUILDING CODE-ACCESSIBILITY PLAN RE-SUBMITTALS SHALL BE ACCOMPANIED BY AN ARCHITECT’S AND / OR ENGINEER’S (DEPENDING ON PLAN SHEETS RE-SUBMITTED), PLAN REVIEW COMMENT RESPONSE LETTER. LETTER SHALL BE SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL AND CONTAIN A VERIFIABLE DIGITAL SIGNATURE AND SEAL COMPLYING WITH FAC. 61G1-16.005 (ARCHITECTS) AND FAC 61G15-23.004 (ENGINEERS). REVISIONS SHALL BE APPROPRIATELY CLOUDED ON PLAN SHEETS. ONLY PLAN SHEETS CONTAINING REVISIONS SHALL BE UPLOADED ON RE-SUBMITTAL. FAILURE TO PROVIDE SIGNED AND SEALED RESPONSE LETTER AND / OR CLOUDING PLAN REVISIONS WILL RESULT IN THE REJECTION OF RE-SUBMITTED PLANS RE-SUBMITTAL BEING REJECTED AND THE PLAN REVIEW(S) NOT COMPLETED. 1. Per FBC 454.1.6. 3 indicate the backflow prevention device used to protect potable water for the pool equipment and deck shower. Please indicate the source of water for the pool. 2. Per Table 454.1.6.1 two (2) water closets are required in the men's restroom, three (3) waters closets are required in the women's restroom. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤260.15) | 12/20/2024 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 12/20/2024 |
| INSPECTION COMMERCIAL | ¤2,170.00 | 12/20/2024 |
| PLAN REVIEW - COMMERCIAL | ¤356.50 | 12/20/2024 |
| SURCHARGE FS 533.721 | ¤23.41 | 12/20/2024 |
| SURCHARGE - FS 468.631 | ¤35.12 | 12/20/2024 |
| SITE PLAN 30 | ¤30.00 | 12/20/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤2,429.88 |