Permit #2024101433

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7023-00370-0300
Block: 00370
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 732-421-5880
Location Address: 25 WHITE HAVEN LN
Type: DR - DRIVEWAY
Issue Date: 10/31/2024
NOC: Unknown
Applicant name: CLAUDIO MIGUEL SARAIVA
Owner: SOMMER SARAH A

Address

25 WHITE HAVEN LANE

PALM COAST, FL 32164

Lot: 0300
Contracted Stated Job Value: ¤5,000.00
Job Description: REF 2022080171 CONCRETE DRIVEWAY EXTENSION
Type: CN
Original Permit #: 2022080171

Contractor

CMS CONSTRUCTION LLC
Status Location Address Phone
INACTIVE

19 BRADDOCK LN

PALM COAST, FL 32137

732-421-5880

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 11/04/2024 APPROVED TPOLACEK
Note: 11/04/24 TPOLACEK*** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 1/27/2023 - PREVIOUS INSPECTION NOTES Need more dirt and sod along the outside edge of the new pour. Water will soon infiltrate under the driveway and undermine as graded and left as-is. Inspector Notes from Inspection 9270 08/30/22=BEFORE YOU POUR THE CONCRETE NEED TO PUMP THE WATER OUT ON THE MITER END AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ................................................................................................................................................................................................................................... FOOTERS NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. CULVERT PIPE IS GOOD
ROW - FINAL INSPECTION 01/27/2023 APPROVED RGROSS
Note: Inspector Notes from Inspection 9270 08/30/22=BEFORE YOU POUR THE CONCRETE NEED TO PUMP THE WATER OUT ON THE MITER END AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ................................................................................................................................................................................................................................... FOOTERS NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. CULVERT PIPE IS GOOD
U -UTILITY RESIDENTIAL FINAL 01/27/2023 FINAL APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 01/27/2023 Disapproved -FEE REQUIRED RGROSS
Note: Need more dirt and sod along the outside edge of the new pour. Water will soon infiltrate under the driveway and undermine as graded and left as-is. Inspector Notes from Inspection 9270 08/30/22=BEFORE YOU POUR THE CONCRETE NEED TO PUMP THE WATER OUT ON THE MITER END AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ................................................................................................................................................................................................................................... FOOTERS NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. CULVERT PIPE IS GOOD
ROW- PRE-APRON (PRE-POUR) 08/30/2022 APPROVED - AS NOTED GBERTOLA
Note: 08/30/22=BEFORE YOU POUR THE CONCRETE NEED TO PUMP THE WATER OUT ON THE MITER END AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ................................................................................................................................................................................................................................... FOOTERS NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. CULVERT PIPE IS GOOD
ROW- PRE-APRON (PRE-POUR) 08/26/2022 Disapproved - NO FEE GBERTOLA
Note: FOOTERS NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. CULVERT PIPE IS GOOD

Review History

Department Status Date In Date Out
ZON COMPLETE 08/18/2022 08/18/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 08/15/2022 08/15/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Circular driveways must actually be a "circular" shape. Please remove the top right portion of the proposed circular driveway where it is straight to make it an actual "circular" driveway.
ENGIN1 COMPLETE 08/03/2022 08/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
UTL COMPLETE 08/03/2022 08/04/2022
Note: Released By: LARRY FITZGERALD - - LFITZGERALD@PALMCOASTGOV.COM
ZON HOLD 08/03/2022 08/03/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Circular driveways must actually be a "circular" shape. Site plan must also demonstrate that the circular driveway maintains the width of 16' at it's widest point. Please provide setback from front property line to bottom edge of proposed circular driveway - not edge of pavement.
BADMIN INFORMATION 08/03/2022 08/03/2022
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC NOT RECORDED/CERTIFIED

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤3.00) 10/31/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/31/2024
SW ENG INSPECTION 40 ¤40.00 10/31/2024
Fees Total Due: ¤0.00 Total Paid: ¤67.00