I want to search for...

Permit #2024110216

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-0350
CONDITIONED SPACE: 2736 sqft
OPENED PORCH (WITH ROOF) : 29 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
GARAGE: 465 sqft
Total Square Footage: 3430 sqft
Block: 00000
Subdivision: -
Job Phone: 386-236-4133
Location Address: 637 MAHOGANY RUN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/05/2024
NOC: RECORDED
Applicant name: LEONARDO CIRO SANCLEMENTE
Owner: VOLUSIA RESIDENTIAL CONSTRUCTION LLC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 0350
Contracted Stated Job Value: ¤314,399.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VOLUSIA RESIDENTIAL CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

CBC1262114 (Exp: 08/31/2026) 386-236-4133

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
HUGH MACDONALD
Status Location Address State License Number Phone
ACTIVE

10825 TOM FOLSOM ROAD, SUITE A

THONOTOSASSA, FL 33592

CCC1329562 (Exp: 08/31/2026) 813-986-4968
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
HARLEY M BRYAN
Status Location Address State License Number Phone
ACTIVE

5223 EDGEWOOD CT

ORMOND BEACH, FL 32174

LI26657 (Exp: 08/31/2028) 386-463-2700

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/25/2025 FINAL APPROVED HCAMACHO
Note: Energy Calcs Approved 6/23/2025 - PREVIOUS INSPECTION NOTES Building is approved, unable to final until Energy calcs for equipment installed is submitted for revision. In the system-GH5SAN44800AAO / FJ4DNXD60L Equipment onsite- GH5SAN54800AAO / FJ5ANXC48L Once revision is submitted and approved, final can be approved. 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25 1. Energy calcs do not match units installed. Breaker sizes are okay FBC(A) 107.4 2. Outdoor kitchen vent duct needs to be sealed up FBC 402.5.1.1 3. Hole behing electrical outlet, under outdoor kitchen vent, needs to be sealed 4. Main master bath has a leak under right side sink 5. Fireplace insert is not installed, leaving an open wall. Please install insert or seal up wall 6. Ice maker box for fridge needs to be secured 7. Right front bedroom needs tile in the shower grouted and sealed. Could not test water in the shower 8. Back wall of garage, right side receptacle, needs to be GFCi protected NEC 210.8 9. Seal up all ceiling penetrations in garage FBC 402.5.1.1 --Noting that the pool is not completed at time of inspection-- New inspection due to canceled inspection Inspector Notes from Inspection 2430 Silt Fence is down all around the property. There is garbage everywhere and blowing into the adjacent properties. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED Inspector Notes from Inspection 2490 Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
BLD - BUILDING FINAL 06/23/2025 Disapproved - NO FEE JSTEWART
Note: Building is approved, unable to final until Energy calcs for equipment installed is submitted for revision. In the system-GH5SAN44800AAO / FJ4DNXD60L Equipment onsite- GH5SAN54800AAO / FJ5ANXC48L Once revision is submitted and approved, final can be approved. 6/18/2025 - PREVIOUS INSPECTION NOTES 6/18/25 1. Energy calcs do not match units installed. Breaker sizes are okay FBC(A) 107.4 2. Outdoor kitchen vent duct needs to be sealed up FBC 402.5.1.1 3. Hole behing electrical outlet, under outdoor kitchen vent, needs to be sealed 4. Main master bath has a leak under right side sink 5. Fireplace insert is not installed, leaving an open wall. Please install insert or seal up wall 6. Ice maker box for fridge needs to be secured 7. Right front bedroom needs tile in the shower grouted and sealed. Could not test water in the shower 8. Back wall of garage, right side receptacle, needs to be GFCi protected NEC 210.8 9. Seal up all ceiling penetrations in garage FBC 402.5.1.1 --Noting that the pool is not completed at time of inspection-- New inspection due to canceled inspection Inspector Notes from Inspection 2430 Silt Fence is down all around the property. There is garbage everywhere and blowing into the adjacent properties. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED Inspector Notes from Inspection 2490 Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
U -UTILITY RESIDENTIAL FINAL 06/18/2025 FINAL APPROVED DHANEY
BLD - BUILDING FINAL 06/18/2025 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 6/18/25 1. Energy calcs do not match units installed. Breaker sizes are okay FBC(A) 107.4 2. Outdoor kitchen vent duct needs to be sealed up FBC 402.5.1.1 3. Hole behing electrical outlet, under outdoor kitchen vent, needs to be sealed 4. Main master bath has a leak under right side sink 5. Fireplace insert is not installed, leaving an open wall. Please install insert or seal up wall 6. Ice maker box for fridge needs to be secured 7. Right front bedroom needs tile in the shower grouted and sealed. Could not test water in the shower 8. Back wall of garage, right side receptacle, needs to be GFCi protected NEC 210.8 9. Seal up all ceiling penetrations in garage FBC 402.5.1.1 --Noting that the pool is not completed at time of inspection-- New inspection due to canceled inspection Inspector Notes from Inspection 2430 Silt Fence is down all around the property. There is garbage everywhere and blowing into the adjacent properties. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED Inspector Notes from Inspection 2490 Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
BLD - BUILDING FINAL 06/17/2025 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2430 Silt Fence is down all around the property. There is garbage everywhere and blowing into the adjacent properties. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED Inspector Notes from Inspection 2490 Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/17/2025 APPROVED PFLANAGAN
Note: CORRECTIONS MADE TO FINAL SURVEY ------------------------------------------------------------------------ 6/11/2025 - PREVIOUS INSPECTION NOTES RIGHT SIDE DRAINAGE PATTERN IS TOO FLAT NEED TO HAVE POSITIVE FALL EVERY 20'. PER CITY CODE Section 300.01 D(4)
ROW FIELD SURVEY /GRADING CERTIFICATION 06/17/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 06/17/2025 APPROVED PFLANAGAN
Note: TALKED WITH CM AND HE IS GOING TO CLEAN CURB AND GUTTER
ROW - FINAL APRON (AFTER POUR) 06/17/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/11/2025 Disapproved - NO FEE PFLANAGAN
Note: RIGHT SIDE DRAINAGE PATTERN IS TOO FLAT NEED TO HAVE POSITIVE FALL EVERY 20'. PER CITY CODE Section 300.01 D(4)
U-CROSS CONNECTION 06/11/2025 APPROVED DHANEY
GAS FINAL 06/11/2025 APPROVED - AS NOTED MGIBSON
Note: PER ''HOA'' U/G TANK IS REQUIRED. A SEPERATE GAS PERMIT WILL BE SUBMITTED TO BUILDING DEPARTMENT FOR APPROVAL
ELECTRIC - EARLY POWER 05/29/2025 APPROVED HCAMACHO
ROW- PRE-APRON (PRE-POUR) 05/21/2025 APPROVED - AS NOTED EMADISON
Note: ** 05/21/25 READY TO SET PAVERS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ________________________________________________________________________________________________________________ 5/1/2025 - PREVIOUS INSPECTION NOTES 5/1/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 05/01/2025 APPROVED FSLADISH
Note: 5/1/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PRE-APRON (PRE-POUR) 05/01/2025 PARTIALLY APPROVED FSLADISH
Note: 5/1/25 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
FRAMING 04/25/2025 APPROVED - AS NOTED HCAMACHO
Note: Silt Fence is down all around the property. There is garbage everywhere and blowing into the adjacent properties. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED Inspector Notes from Inspection 2490 Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
INSULATION 04/16/2025 APPROVED - AS NOTED JSTEWART
Note: Previous note not rectified. Please submit a revision of Product approval for windows installed, Multiple FL code #'s are not listed. this will need to be submitted prior to calling in for the final. Inspector Notes from Inspection 2420 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
GAS ROUGH 04/11/2025 APPROVED MCONTRYMAN
ALL ROUGH 04/11/2025 APPROVED - AS NOTED MCONTRYMAN
Note: 4/11/25 1. Product approvals must show FPA for window MI 17676. Please revise and get approved by next inspection
GRAVITY SEWER TEST 04/11/2025 APPROVED MGIBSON
Note: 4/10/2025 - PREVIOUS INSPECTION NOTES 4/9/2025 - PREVIOUS INSPECTION NOTES Line are empty. FBCR P2503.5 STILL NO WATER IN SEWER MAIN. FBCR P-2303.5
GRAVITY SEWER TEST 04/10/2025 Disapproved - NO FEE MGIBSON
Note: 4/9/2025 - PREVIOUS INSPECTION NOTES Line are empty. FBCR P2503.5 STILL NO WATER IN SEWER MAIN. FBCR P-2303.5
GRAVITY SEWER TEST 04/09/2025 Disapproved - NO FEE JSTEWART
Note: Line are empty. FBCR P2503.5
SEWER TIE IN 04/09/2025 APPROVED JSTEWART
LATH/BRICK/ WATER BARRIER 04/04/2025 APPROVED HCAMACHO
Note:
ROOF VALLEY & METAL 03/27/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Garbage needs to be contained. FBC 3302.2 NEEDS DUMPSTER 2. Silt fence needs to be put up on the left side of the house. FBC 3307.1 NEEDS SILT FENCE PROPERLY INSTALLED
WALL SHEATHING 03/20/2025 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/20/2025 APPROVED HCAMACHO
ELECTRIC-TUG 03/20/2025 APPROVED HCAMACHO
FOUND SURVEY APPROVED (OFFICE) 03/10/2025 APPROVED RRICKS
TIE BEAM / LINTEL 03/10/2025 APPROVED HCAMACHO
MONOLITHIC SLAB 02/25/2025 APPROVED HCAMACHO
PLUMBING 1ST ROUGH UNDERGROUND 02/20/2025 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/10/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 06/23/2025 06/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 06/10/2025 06/10/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO FINAL SURVEY.PDF
ENGIN1 COMPLETE 03/10/2025 03/10/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/10/2025 03/10/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/10/2025 02/12/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 02/10/2025 02/13/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 02/10/2025 02/10/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/10/2025 02/11/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/30/2025 01/30/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 01/30/2025 01/30/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/30/2025 01/30/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 01/08/2025 01/08/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 01/08/2025 01/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 01/08/2025 01/09/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/08/2025 01/13/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
BADMIN INFORMATION 01/06/2025 01/06/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM PLANS MUST BE SUBMITTED INDIVIDUALLY
BADMIN INFORMATION 01/06/2025 01/06/2025
Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM must completet the previous hold on (12/30 - changed site plan) before you can proceed with another revision.
ENGIN1 COMPLETE 12/30/2024 12/31/2024
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 12/30/2024 12/31/2024
Note: Held By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM Please state changes.
ZON HOLD 12/30/2024 12/30/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM PLease advise what changes took place
BLD COMPLETE 12/19/2024 12/27/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 11/26/2024 12/04/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/14/2024 11/25/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
MECH HOLD 11/14/2024 11/19/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State card is one page with preparers signature, not entire energy calc. Upload that page only (Second Request)
ENGIN1 COMPLETE 11/14/2024 11/14/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/14/2024 11/14/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 HOLD 11/07/2024 11/08/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please show proposed elevations at the rear of the lot. These elevations need to be 10' offset from the structure and be at least 0.50' lower than the sod elevations at the structure.
URB COMPLETE 11/07/2024 11/14/2024
Note: Released By: MATTHEW SIERRA - -
BADMIN COMPLETE 11/05/2024 11/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/05/2024 11/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 11/05/2024 11/07/2024
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 11/05/2024 11/08/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/05/2024 11/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS COMPLETE 11/05/2024 11/12/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 11/05/2024 11/13/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 11/05/2024 11/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State card is one page with preparers signature, not entire energy calc. Upload that page only
SW1 HOLD 11/05/2024 11/06/2024
Note: Held By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM Please show proposed elevations at the rear of the lot. These elevations need to be 10' offset from the structure and be at least 0.50' lower than the sod elevations at the structure.
ZON COMPLETE 11/05/2024 11/07/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/25/2025
PLAN REVIEW - REVISION ¤32.50 06/25/2025
REINSPECTION RESIDENTIAL ¤40.00 06/25/2025
CONNECTION FEES ¤25.00 12/05/2024
FC IMPACT FEE EMS ¤62.00 12/05/2024
IMPACT FEE FIRE ¤434.51 12/05/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/05/2024
FC IMPACT FEE LIBRARY ¤268.00 12/05/2024
IMPACT FEE PARKS ¤1,828.01 12/05/2024
IMPACT FEE SCHOOL ¤5,450.00 12/05/2024
IMPACT FEE TRANSPORTATION ¤3,404.00 12/05/2024
SURCHARGE FS 533.721 ¤16.25 12/05/2024
SURCHARGE - FS 468.631 ¤24.38 12/05/2024
SW ENG - FOUNDATION SURVEY ¤20.00 12/05/2024
SW ENG INSPECTION 80 ¤80.00 12/05/2024
SW ENG PRE APRON ¤30.00 12/05/2024
SW ENG - REVIEW 20 ¤20.00 12/05/2024
SW ENG RES REVIEW 200 ¤200.00 12/05/2024
SEWER INSPECTION ¤25.00 12/05/2024
SITE PLAN 30 ¤30.00 12/05/2024
WATER-METER ¤514.49 12/05/2024
ADJUSTMENT 10% (¤180.56) 12/05/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/05/2024
INSPECTION - RESIDENTIAL ¤1,383.25 12/05/2024
PLAN REVIEW - RESIDENTIAL ¤392.34 12/05/2024
Fees Total Due: ¤0.00 Total Paid: ¤14,379.67