I want to search for...

Permit #2024110427

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7025-00550-0160
Total Square Footage: 2286 sqft
Block: 00550
Subdivision: 7025 -
Job Phone: 561-329-2819
Location Address: 33 PANEI LN
Type: WD - WINDOWS/DOORS
Issue Date: 11/18/2024
NOC: RECORDED
Applicant name: SCOTT L BERMAN
Owner: FANNING JENNNIFER & DAVID H&W

Address

33 PANEI LANE

PALM COAST, FL 32164

Lot: 0160
Contracted Stated Job Value: ¤23,760.00
Job Description: INSTALL 10 IMPACT WINDOWS
Type: CN

Contractor

FLORIDA WINDOW & DOOR
Status Location Address State License Number Phone
ACTIVE

1125 N DIXIE HIGHWAY

LAKE WORTH, FL 33460

CGC1509450 (Exp: 08/31/2026) 561-228-1884

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 05/23/2025 FINAL APPROVED JSTEWART
Note: 4/2/2025 - PREVIOUS INSPECTION NOTES 4/2/25: Approved homeowner to remove stickers. All verified. Please make sure that you are fully ready for Final inspection. Anchor covers will need to remain unistalled so anchors can be checked. 1). Living room window pane is still cracked. FBC [A]107.4 2). Dining room center window is missing anchors. FBC [A]107.4 3). Back left bedroom: Window rail guides are hanging up causing them to bend excessively. FBC [A]107.4 4). Right side bathroom window: Window rail guides are hanging up causing them to bend excessively. 5). Left side bathroom window: Missing anchors. FBC [A]107.4 6). Front windows: need to be sealed properly. (installer was working on correcting during the inspection). Re-check. FBC [A]107.4 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25: NOT READY FOR FINAL INSPECTION! (Incomplete Inspection). Examples (Only): Multiple windows are not sealed on the outside or inside, front window has cracked glass, FBC [A]107.4 / frames are over torqued where solid backing is required, gaps and spaces exceed 1/4" maximum shim space - FBCR 609.1
FINAL - BUILDING MISC 04/02/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/2/2025 8:51:36 AM *** Code for deficiencies = FBC [A]107.4 *** NOTES ADDED BY RSIMS 4/2/2025 8:49:52 AM *** 4/2/25: Approved homeowner to remove stickers. All verified. Please make sure that you are fully ready for Final inspection. Anchor covers will need to remain unistalled so anchors can be checked. 1). Living room window pane is still cracked. 2). Dining room center window is missing anchors. 3). Back left bedroom: Window rail guides are hanging up causing them to bend excessively. 4). Right side bathroom window: Window rail guides are hanging up causing them to bend excessively. 5). Left side bathroom window: Missing anchors. 6). Front windows: need to be sealed properly. (installer was working on correcting during the inspection). Re-check. 3/4/2025 - PREVIOUS INSPECTION NOTES 3/4/25: NOT READY FOR FINAL INSPECTION! (Incomplete Inspection). Examples (Only): Multiple windows are not sealed on the outside or inside, front window has cracked glass, FBC [A]107.4 / frames are over torqued where solid backing is required, gaps and spaces exceed 1/4" maximum shim space - FBCR 609.1
FINAL - BUILDING MISC 03/04/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/4/2025 1:38:32 PM *** 3/4/25: NOT READY FOR FINAL INSPECTION! (Incomplete Inspection). Examples (Only): Multiple windows are not sealed on the outside or inside, front window has cracked glass, FBC [A]107.4 / frames are over torqued wherer solid backing is required, gaps and spaces exceed 1/4" maximum shim space - FBCR 609.1

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/20/2025
REINSPECTION RESIDENTIAL ¤40.00 03/25/2025
SURCHARGE FS 533.721 ¤2.00 11/18/2024
SURCHARGE - FS 468.631 ¤2.00 11/18/2024
ADJUSTMENT 10% (¤9.60) 11/18/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/18/2024
INSPECTION - RESIDENTIAL ¤66.00 11/18/2024
Fees Total Due: ¤0.00 Total Paid: ¤170.40