I want to search for...

Permit #2024110495

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7025-00450-0230
Block: 00450
Subdivision: 7025 -
Job Phone: 386-999-1042
Location Address: 65 PUTTER DR
Type: PO - POOL
Issue Date: 11/18/2024
NOC: RECORDED
Applicant name: RYDER N BRAY
Owner: TRAUBERT CHARLES LIFE ESTATE

Address

65 PUTTER DRIVE

PALM COAST, FL 32164

Lot: 0230
Contracted Stated Job Value: ¤120,000.00
Job Description: POOL, SCREEN ENCLOSURE
Type: CN

Contractor

HAVEN POOLS LLC
Status Location Address State License Number Phone
ACTIVE

25 PUTTER LANE

PALM COAST, FL 32164

CPC1460243 (Exp: 08/31/2026) 386-999-1042

Sub Contractors

JOSEPH DEREK CARTWRIGHT
Status Location Address State License Number Phone Fax
ACTIVE

151 RODEO ROAD

ORMOND BEACH, FL 32174

SCC131150000 (Exp: 08/31/2026) 386-310-7962 (386)615-3713
JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144

Inspection History

Type Request Date Result Inspector
POOL FINAL 02/27/2025 APPROVED CVANSTRAHLEN
Note: 2/26/2025 - PREVIOUS INSPECTION NOTES 2/26/25). 1). Trash and excess material needs to be removed from driveway prior to Final Inspection. FBC [A]107.4 2). Remote alarm is sitting on the table on Lanai. Remote alarm needs to be placed inside the house close to a window or door so that it is both visible and can be heard from outside for the inspection. FBC- R4501.17.1.9 3). Ground wire at the back center part of the pool outside the screen enclosure needs to be protected from damage as required. NEC 250-92 1/6/25: Right side of House: Swale at front of job site and immedietely adjacent at Neighboring lot will need to be repaired from damage caused by build process.
POOL FINAL 02/26/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/26/2025 2:44:09 PM *** 2/26/25). 1). Trash and excess material needs to be removed from driveway prior to Final Inspection. FBC [A]107.4 2). Remote alarm is sitting on the table on Lanai. Remote alarm needs to be placed inside the house close to a window or door so that it is both visible and can be heard from outside for the inspection. FBC- R4501.17.1.9 3). Ground wire at the back center part of the pool outside the screen enclosure needs to be protected from damage as required. NEC 250-92 1/6/25: Right side of House: Swale at front of job site and immedietely adjacent at Neighboring lot will need to be repaired from damage caused by build process.
U -UTILITY RESIDENTIAL FINAL 02/24/2025 FINAL APPROVED LFITZGERALD
Note: 2/18/2025 - PREVIOUS INSPECTION NOTES locate existing sewer clean out and make avaiable
U -UTILITY RESIDENTIAL FINAL 02/18/2025 Disapproved -FEE REQUIRED LFITZGERALD
Note: locate existing sewer clean out and make avaiable
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/14/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 02/14/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 02/14/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC AND ALARM 02/05/2025 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/5/2025 1:52:38 PM *** M1307.2/M1401.1 *** NOTES ADDED BY RSIMS 2/5/2025 1:52:07 PM *** 2/5/25: Pool heating unit will need the 4 required anchors prior to Pool Final Inspection.
POOL DECK 01/06/2025 APPROVED RSIMS
STEEL AND GROUND 12/06/2024 APPROVED RSIMS

Review History

Department Status Date In Date Out
BLD COMPLETE 11/12/2024 11/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 11/12/2024 11/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/12/2024 11/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/12/2024 11/13/2024
Note: Released By: TOM POLACEK - (386)346-8986 -
ZON COMPLETE 11/12/2024 11/12/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/26/2025
REINSPECTION FEE ¤40.00 02/25/2025
SURCHARGE FS 533.721 ¤2.55 11/18/2024
SURCHARGE - FS 468.631 ¤3.83 11/18/2024
SW ENG INSPECTION 40 ¤40.00 11/18/2024
SW ENG - REVIEW 20 ¤20.00 11/18/2024
SITE PLAN 30 ¤30.00 11/18/2024
ADJUSTMENT 10% (¤28.36) 11/18/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/18/2024
INSPECTION- POOL ¤160.00 11/18/2024
PLAN REVIEW - RESIDENTIAL ¤93.60 11/18/2024
Fees Total Due: ¤0.00 Total Paid: ¤431.62