I want to search for...
Permit #2024110518
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00030-0270 |
| GARAGE: 713 sqft |
| CONDITIONED SPACE: 1810 sqft |
| PATIO/DECK (NO ROOF) : 136 sqft |
| OPENED PORCH (WITH ROOF) : 123 sqft |
| Total Square Footage: 2782 sqft |
| Block: 00030 |
| Subdivision: - |
| Job Phone: 904-888-6443 |
| Location Address: 14 FERNGATE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/05/2024 |
| NOC: RECORDED |
| Applicant name: AMIR BENTOV |
| Owner: 3DRE LLC |
|
Address 2800 N 6TH ST ST AUGUSTINE, FL 32084 |
|
Address 790 ST AUGUSTINE, FL 32084 |
| Lot: 0270 |
| Contracted Stated Job Value: ¤280,000.00 |
| Job Description: Residential |
| Type: CN |
Contractor
MAVEN HOMES LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2800 N 6TH ST UNIT 790 , |
CRC1333741 (Exp: 08/31/2026) | 904-667-4330 |
Sub Contractors
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/30/2026 | Approval - Private Provider | PPROVIDER |
| Note: 3/11/2026 3:17:27 PM- PREVIOUS INSPECTION NOTES | |||
| U -UTILITY RESIDENTIAL FINAL | 03/30/2026 | PARTIALLY APPROVED | BWRIGHT |
| Note: Inspector Notes from Inspection 9035 No IRR, No CC | |||
| U -UTILITY RESIDENTIAL FINAL | 03/30/2026 | FINAL APPROVED | BWRIGHT |
| Note: 3/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No IRR, No CC | |||
| BLD - BUILDING FINAL | 03/10/2026 | Disapproved- Private Provider | PPROVIDER |
| ELECTRIC - EARLY POWER | 02/11/2026 | Approval - Private Provider | PPROVIDER |
| ROW - STORMWATER FINAL | 12/26/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 12/9/2025 - PREVIOUS INSPECTION NOTES ** 12/09/25 RIGHT SIDE AT REAR CORNER OF STRUCTURE ALONG PROPERTY LINE YOUR DRAINAGE IS INCONSISTANT AND IS HOLDING WATER ** RIGHT SIDE ROAD SIDE SWALE IS FLOW IS INCONSISTANT WILL HOLD WATER ALSO CENTER OF SWALE NEEDS TO BE RE-ESTABLISHED AND SHOULD BE 8 FT FROM EDGE OF ROAD TO THE CENTER. ** VACANT LOT NEED TO CUT IN SOD TO MATCH EXISTING GRADE __________________________________________________________________________________________________________________________ 11/18/2025 - PREVIOUS INSPECTION NOTES 11-18-25 TPOLACEK*** ENTIRE CULVERT MUST BE FREE AND CLEAR OF SEDIMENT FROM END TO END. RIGHT SIDE FROM BACK CORNER OF STRUCTURE DRAINAGE CONVEYANCE IS HOLDING WATER AND SHOULD BE GRADED TO ALLOW WATER TO FLOW TO FRONT SWALE. THERE IS PLENTY OF ELEVATION TO ACHIEVE THIS. IN FRONT SWALE ON RIGHT SIDE, SWALE SHOULD MATCH GRADE AT PROPERTY LINE AND BE GRADED TO ALLOW DRAINAGE TO FLOW AS REQUIRED. THERE ARE SEVERAL RUTS THAT WILL TRAP DRAINAGE FROM WHERE MACHINE MADE ENTRY. PLEASE MAKE ALL CORRECTIONS BEFORE REQUESTING STORMWATER FINAL ROW INSPECTION Inspector Notes from Inspection 9465 ** 10/20/25 BEFORE THE ROW STORMWATER FINAL YOU ARE REQUIRED TO CLEAN ENTIRE CULVERT PIPE OF ALL SEDIMENT ** YOU ALSO ARE REQUIRED TO CUT GRASS BEFORE ROW STORMWATER FINAL SO THE INSPECTOR CAN BETTER IDENTIFY ALL DRAINAGE FEATURES ** ENSURE ALL TRASH AND CONSTRUCTION DEBRIS IS REMOVED FROM VACANT LOT AND SEED AND STRAW ALL BARE EARTH AREAS | |||
| ROW - STORMWATER FINAL | 12/09/2025 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 12/09/25 RIGHT SIDE AT REAR CORNER OF STRUCTURE ALONG PROPERTY LINE YOUR DRAINAGE IS INCONSISTANT AND IS HOLDING WATER ** RIGHT SIDE ROAD SIDE SWALE IS FLOW IS INCONSISTANT WILL HOLD WATER ALSO CENTER OF SWALE NEEDS TO BE RE-ESTABLISHED AND SHOULD BE 8 FT FROM EDGE OF ROAD TO THE CENTER. ** VACANT LOT NEED TO CUT IN SOD TO MATCH EXISTING GRADE __________________________________________________________________________________________________________________________ 11/18/2025 - PREVIOUS INSPECTION NOTES 11-18-25 TPOLACEK*** ENTIRE CULVERT MUST BE FREE AND CLEAR OF SEDIMENT FROM END TO END. RIGHT SIDE FROM BACK CORNER OF STRUCTURE DRAINAGE CONVEYANCE IS HOLDING WATER AND SHOULD BE GRADED TO ALLOW WATER TO FLOW TO FRONT SWALE. THERE IS PLENTY OF ELEVATION TO ACHIEVE THIS. IN FRONT SWALE ON RIGHT SIDE, SWALE SHOULD MATCH GRADE AT PROPERTY LINE AND BE GRADED TO ALLOW DRAINAGE TO FLOW AS REQUIRED. THERE ARE SEVERAL RUTS THAT WILL TRAP DRAINAGE FROM WHERE MACHINE MADE ENTRY. PLEASE MAKE ALL CORRECTIONS BEFORE REQUESTING STORMWATER FINAL ROW INSPECTION Inspector Notes from Inspection 9465 ** 10/20/25 BEFORE THE ROW STORMWATER FINAL YOU ARE REQUIRED TO CLEAN ENTIRE CULVERT PIPE OF ALL SEDIMENT ** YOU ALSO ARE REQUIRED TO CUT GRASS BEFORE ROW STORMWATER FINAL SO THE INSPECTOR CAN BETTER IDENTIFY ALL DRAINAGE FEATURES ** ENSURE ALL TRASH AND CONSTRUCTION DEBRIS IS REMOVED FROM VACANT LOT AND SEED AND STRAW ALL BARE EARTH AREAS | |||
| ROW - STORMWATER FINAL | 11/18/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 11-18-25 TPOLACEK*** ENTIRE CULVERT MUST BE FREE AND CLEAR OF SEDIMENT FROM END TO END. RIGHT SIDE FROM BACK CORNER OF STRUCTURE DRAINAGE CONVEYANCE IS HOLDING WATER AND SHOULD BE GRADED TO ALLOW WATER TO FLOW TO FRONT SWALE. THERE IS PLENTY OF ELEVATION TO ACHIEVE THIS. IN FRONT SWALE ON RIGHT SIDE, SWALE SHOULD MATCH GRADE AT PROPERTY LINE AND BE GRADED TO ALLOW DRAINAGE TO FLOW AS REQUIRED. THERE ARE SEVERAL RUTS THAT WILL TRAP DRAINAGE FROM WHERE MACHINE MADE ENTRY. PLEASE MAKE ALL CORRECTIONS BEFORE REQUESTING STORMWATER FINAL ROW INSPECTION Inspector Notes from Inspection 9465 ** 10/20/25 BEFORE THE ROW STORMWATER FINAL YOU ARE REQUIRED TO CLEAN ENTIRE CULVERT PIPE OF ALL SEDIMENT ** YOU ALSO ARE REQUIRED TO CUT GRASS BEFORE ROW STORMWATER FINAL SO THE INSPECTOR CAN BETTER IDENTIFY ALL DRAINAGE FEATURES ** ENSURE ALL TRASH AND CONSTRUCTION DEBRIS IS REMOVED FROM VACANT LOT AND SEED AND STRAW ALL BARE EARTH AREAS | |||
| ROW - FINAL APRON (AFTER POUR) | 11/18/2025 | APPROVED - AS NOTED | TPOLACEK |
| Note: 11-18-25 TPOLACEK*** APPROVING AFTER POUR AS NOTED, CULVERT IS STILL 1/2 FULL OF SEDIMENT AND MUST BE CLEANED END TO END, INSPECTOR WILL ADD THIS TO THE FINAL ROW INSPECTION RESULTS. Inspector Notes from Inspection 9465 ** 10/20/25 BEFORE THE ROW STORMWATER FINAL YOU ARE REQUIRED TO CLEAN ENTIRE CULVERT PIPE OF ALL SEDIMENT ** YOU ALSO ARE REQUIRED TO CUT GRASS BEFORE ROW STORMWATER FINAL SO THE INSPECTOR CAN BETTER IDENTIFY ALL DRAINAGE FEATURES ** ENSURE ALL TRASH AND CONSTRUCTION DEBRIS IS REMOVED FROM VACANT LOT AND SEED AND STRAW ALL BARE EARTH AREAS | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/20/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** 10/20/25 BEFORE THE ROW STORMWATER FINAL YOU ARE REQUIRED TO CLEAN ENTIRE CULVERT PIPE OF ALL SEDIMENT ** YOU ALSO ARE REQUIRED TO CUT GRASS BEFORE ROW STORMWATER FINAL SO THE INSPECTOR CAN BETTER IDENTIFY ALL DRAINAGE FEATURES ** ENSURE ALL TRASH AND CONSTRUCTION DEBRIS IS REMOVED FROM VACANT LOT AND SEED AND STRAW ALL BARE EARTH AREAS | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/30/2025 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 09/30/25 CANCELLED ON SITE BY CONSTRUCTION MANAGER ____________________________________________________________________________________________________________ 9/23/2025 - PREVIOUS INSPECTION NOTES ** 09/23/25 RIGHT REAR CORNER OFF REAR PATIO AND DOWN ENTIRE RIGHT SIDE HOLDING WATER NEED TO HAVE POSITIVE FALL OF WATER FROM THE REAR TO THE FRONT YOUR DRAINAGE CONVEYANCE HAS INCONSISTANT FLOW. ** 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 ** ROAD SIDE SWALE RIGHT FRONT HAS LOW AREA NEED TO ALSO HAVE POSITIVE FALL FROM LEFT TO RIGHT | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/23/2025 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/23/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 09/23/25 RIGHT REAR CORNER OFF REAR PATIO AND DOWN ENTIRE RIGHT SIDE HOLDING WATER NEED TO HAVE POSITIVE FALL OF WATER FROM THE REAR TO THE FRONT YOUR DRAINAGE CONVEYANCE HAS INCONSISTANT FLOW. ** 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17 ** ROAD SIDE SWALE RIGHT FRONT HAS LOW AREA NEED TO ALSO HAVE POSITIVE FALL FROM LEFT TO RIGHT | |||
| U-CROSS CONNECTION | 09/23/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: No IRR, No CC | |||
| ROW- PRE-APRON (PRE-POUR) | 07/15/2025 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| GRAVITY SEWER TEST | 07/01/2025 | Approval - Private Provider | PPROVIDER |
| SEWER TIE IN | 07/01/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 06/20/2025 | Approval - Private Provider | PPROVIDER |
| INSULATION | 06/10/2025 | Approval - Private Provider | PPROVIDER |
| Note: 6/5/2025 4:34:42 PM- PREVIOUS INSPECTION NOTES | |||
| INSULATION | 06/05/2025 | Disapproved- Private Provider | PPROVIDER |
| ALL ROUGH | 05/28/2025 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 03/19/2025 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/19/2025 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 03/19/2025 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 02/04/2025 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 02/04/2025 | APPROVED | RRICKS |
| TIE BEAM / LINTEL | 02/03/2025 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 01/31/2025 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 01/24/2025 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 01/22/2025 | CANCELLED BY APPLICANT | WEB |
| ROW - DRAINAGE | 01/22/2025 | APPROVED - AS NOTED | EMADISON |
| Note: ** CORRECTIONS MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY ________________________________________________________________________________________________________________________ 1/15/2025 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. 2) NEED TO INSTALL A SILT FENCE AROUND LOT. 3) NEED TO KEEP TEMP. CULVERT OPEN AT ALL TIMES DURING CONSTRUCTION SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAYS TO CORRECT ALL OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/21/2025 | Approval - Private Provider | PPROVIDER |
| ROW - DRAINAGE | 01/15/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO REMOVE PORTER JOHN FROM THE RIGHT OF WAY AND PLACE IT ON YOUR LOT. 2) NEED TO INSTALL A SILT FENCE AROUND LOT. 3) NEED TO KEEP TEMP. CULVERT OPEN AT ALL TIMES DURING CONSTRUCTION SO WATER CAN FLOW TO OUTFALL. YOU WILL HAVE 7DAYS TO CORRECT ALL OR THERE WILL BE A INSPECTION HOLD ON THIS PERMIT. | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 12/31/2024 | APPROVED | JMUNSON |
| WATER METER INSTALLATION REQUEST | 12/11/2024 | APPROVED | CBOWERMASTER |
| WILDLIFE CHECK - ENVIRONMENTAL | 11/20/2024 | APPROVED | DRODRIGUEZ |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 01/30/2025 | 02/04/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/30/2025 | 01/30/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/20/2024 | 12/31/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/20/2024 | 11/20/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 11/20/2024 | 11/20/2024 |
| Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Attached letter from the QEP meets city requirements for compliance With 10.04.01 of the LDC. If any Gopher Tortoises or their burrows are found in the future, further coordination may be needed. | |||
| MECH | COMPLETE | 11/20/2024 | 11/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/20/2024 | 11/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 11/12/2024 | 11/19/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/12/2024 | 11/19/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Truss packet or truss layout need shop drawing approval stamp by EOR 2. Geo Tech needs to be digitally signed and sealed. | |||
| CUSVC | COMPLETE | 11/12/2024 | 11/15/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/12/2024 | 11/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/12/2024 | 11/12/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 11/12/2024 | 11/18/2024 |
| LOCATE | COMPLETE | 11/12/2024 | 11/14/2024 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 11/12/2024 | 11/18/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State Card needs to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition | |||
| SW1 | COMPLETE | 11/12/2024 | 11/13/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | HOLD | 11/12/2024 | 11/13/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM House layout and ac location does not match on landscape plan | |||
| PLENV | HOLD | 11/12/2024 | 11/14/2024 |
| Note: Held By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 11/14/24 and found potentially occupied Gopher Tortoise burrow. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed. | |||
| SWALE | COMPLETE | 11/12/2024 | 12/12/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/30/2026 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/30/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/30/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 03/30/2026 |
| SURCHARGE FS 533.721 | ¤5.09 | 12/05/2024 |
| SURCHARGE - FS 468.631 | ¤7.64 | 12/05/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/05/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/05/2024 |
| SW ENG PRE APRON | ¤30.00 | 12/05/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/05/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/05/2024 |
| SEWER CREDIT | (¤3,042.43) | 12/05/2024 |
| SEWER INSPECTION | ¤25.00 | 12/05/2024 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 12/05/2024 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 12/05/2024 |
| SITE PLAN 30 | ¤30.00 | 12/05/2024 |
| WATER- TURN ON | ¤25.00 | 12/05/2024 |
| ADJUSTMENT 10% | (¤31.55) | 12/05/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/05/2024 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 12/05/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤285.48 | 12/05/2024 |
| CONNECTION FEES | ¤1,187.26 | 12/05/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 12/05/2024 |
| IMPACT FEE FIRE | ¤434.51 | 12/05/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 12/05/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 12/05/2024 |
| IMPACT FEE PARKS | ¤1,828.01 | 12/05/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 12/05/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,862.00 | 12/05/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/05/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,825.67 |