I want to search for...

Permit #2024110580

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00250-0100
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00250
Subdivision: -
Job Phone: 689-250-2429
Location Address: 29 PRINCETON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/10/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE DEVELOPMENT LLC

Address

688 N ORLANDO AVENUE

MAITLAND, FL 32751

Address

SUITE 207

MAITLAND, FL 32751

Lot: 0100
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 08/29/2025 APPROVED - AS NOTED TPOLACEK
Note: 08/29/25 TPOLACEK*** BUILDER NEEDS TO REMOVE ALL SEDIMENT FROM CULVERT. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 08/29/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/28/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/28/2025 APPROVED TPOLACEK
Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
BLD - BUILDING FINAL 08/22/2025 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 08/04/2025 APPROVED - AS NOTED TPOLACEK
Note: 08/04/25 TPOLACEK*** MAKE SURE TO REESTABLISH FOOTERS PRIOR TO POURING CONCRETE AS WELL AS BACK FILLING ALL BOARDS TO PREVENT OVER POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. 8/1/2025 - PREVIOUS INSPECTION NOTES 08/01/25 TPOLACEK*** WASHOUTS HAVE BEEN RAKED OUT HOWEVER THE FOOTERS ARE STILL WASHED IN AND APRON SLOPE IS STILL PITCHED BACK TOWARDS CULVERT. PLEASE MAKE CORRECTIONS BEFORE REQUESTING INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/30/2025 - PREVIOUS INSPECTION NOTES 07/30/25 TPOLACEK**** CULVERT ELEVATION IS GOOD. HOWEVER, RIGHT SIDE APRON WING IS SLOPED TOWARDS THE CULVERT INSTEAD OF THE ROAD, POUR AREA IS WSHED OUT AND FOOTERS NEED TO BE REESTABLISHED BEFORE POUR WILL BE APPROVED.
ROW- PRE-APRON (PRE-POUR) 08/01/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 08/01/25 TPOLACEK*** WASHOUTS HAVE BEEN RAKED OUT HOWEVER THE FOOTERS ARE STILL WASHED IN AND APRON SLOPE IS STILL PITCHED BACK TOWARDS CULVERT. PLEASE MAKE CORRECTIONS BEFORE REQUESTING INSPECTION. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 7/30/2025 - PREVIOUS INSPECTION NOTES 07/30/25 TPOLACEK**** CULVERT ELEVATION IS GOOD. HOWEVER, RIGHT SIDE APRON WING IS SLOPED TOWARDS THE CULVERT INSTEAD OF THE ROAD, POUR AREA IS WSHED OUT AND FOOTERS NEED TO BE REESTABLISHED BEFORE POUR WILL BE APPROVED.
INSULATION 07/31/2025 Approval - Private Provider PPROVIDER
ALL ROUGH 07/30/2025 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 07/30/2025 Disapproved - NO FEE TPOLACEK
Note: 07/30/25 TPOLACEK**** CULVERT ELEVATION IS GOOD. HOWEVER, RIGHT SIDE APRON WING IS SLOPED TOWARDS THE CULVERT INSTEAD OF THE ROAD, POUR AREA IS WSHED OUT AND FOOTERS NEED TO BE REESTABLISHED BEFORE POUR WILL BE APPROVED.
ROOF VALLEY & METAL 07/24/2025 Approval - Private Provider PPROVIDER
ELECTRIC - EARLY POWER 07/11/2025 Approval - Private Provider PPROVIDER
GRAVITY SEWER TEST 06/27/2025 Approval - Private Provider PPROVIDER
U-CROSS CONNECTION 06/27/2025 APPROVED - AS NOTED LFITZGERALD
Note: NOO= irr-no cc
U - SEWER TIE IN 06/27/2025 APPROVED MGIBSON
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/29/2025 Approval - Private Provider PPROVIDER
LATH/BRICK/ WATER BARRIER 05/29/2025 Approval - Private Provider PPROVIDER
PLUMBING 1ST ROUGH UNDERGROUND 05/29/2025 Approval - Private Provider PPROVIDER
TIE BEAM / LINTEL 04/23/2025 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 04/23/2025 Approval - Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 04/11/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 02/18/2025 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 01/28/2025 APPROVED CBOWERMASTER
Note: 1/24/2025 2:15:27 PM- PREVIOUS INSPECTION NOTES 1/13/2025 9:37:39 AM- PREVIOUS INSPECTION NOTES 1/6/2025 7:42:13 AM- PREVIOUS INSPECTION NOTES lot not cleared still clearing garbage right side of property
WATER METER INSTALLATION REQUEST 01/24/2025 Disapproved -FEE REQUIRED CBOWERMASTER
Note: 1/13/2025 9:37:39 AM- PREVIOUS INSPECTION NOTES 1/6/2025 7:42:13 AM- PREVIOUS INSPECTION NOTES lot not cleared still clearing garbage right side of property
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/22/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/10/2025 Disapproved -FEE REQUIRED CBOWERMASTER
Note: 1/6/2025 7:42:13 AM- PREVIOUS INSPECTION NOTES lot not cleared still clearing
WATER METER INSTALLATION REQUEST 01/03/2025 Disapproved -FEE REQUIRED CBOWERMASTER
Note: lot not cleared

Review History

Department Status Date In Date Out
BADMIN INFORMATION 08/27/2025 08/27/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please submit the inspection summary and the certificate of compliance at the same time. Summarization of all inspections performed o A notarized statement signed by the private provider “To the best of my knowledge and belief, the building components and site improvements outlined herein and inspected under my authority have been completed in conformance with the approved plans and the applicable codes”.
BADMIN INFORMATION 08/21/2025 08/21/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM INSPECTION NOT SCHEDULED FOR 2750 (BUILDING FINAL)
MECH COMPLETE 08/06/2025 08/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 04/22/2025 04/22/2025
Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Inspection notice shall be requested through the online permitting portal, Alexa or the 24 hour inspection line 386-986-4747. Cannot process the uploaded results until the inspection has been requested
ENGIN1 COMPLETE 04/11/2025 04/11/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/11/2025 04/11/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 01/15/2025 01/22/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 12/20/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 11/19/2024 11/19/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/19/2024 11/20/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/19/2024 12/05/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
SWALE COMPLETE 11/13/2024 12/12/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 11/12/2024 11/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 11/12/2024 11/15/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/12/2024 11/13/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 11/12/2024 11/15/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
SW1 COMPLETE 11/12/2024 11/13/2024
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any deviation from the approved site plan with significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD
ZON HOLD 11/12/2024 11/18/2024
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plans must show width of walkway
MECH COMPLETE 11/12/2024 11/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/29/2025
REINSPECTION FEE ¤40.00 08/29/2025
REINSPECTION FEE ¤40.00 08/29/2025
REINSPECTION FEE ¤40.00 08/29/2025
SW ENG REINSPECTION 30 ¤30.00 08/29/2025
SW ENG - REVIEW 20 ¤20.00 12/10/2024
SW ENG RES REVIEW 200 ¤200.00 12/10/2024
SEWER CREDIT (¤1,147.00) 12/10/2024
SEWER INSPECTION ¤25.00 12/10/2024
SEWER CAPITAL FACILITY ¤6,120.52 12/10/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 12/10/2024
SITE PLAN 30 ¤30.00 12/10/2024
WATER- TURN ON ¤25.00 12/10/2024
ADJUSTMENT 10% (¤11.32) 12/10/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/10/2024
ADMINISTRATIVE - RESID PP ¤225.00 12/10/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 12/10/2024
SURCHARGE FS 533.721 ¤3.27 12/10/2024
SURCHARGE - FS 468.631 ¤4.90 12/10/2024
SW ENG - FOUNDATION SURVEY ¤20.00 12/10/2024
SW ENG INSPECTION 80 ¤80.00 12/10/2024
SW ENG PRE APRON ¤30.00 12/10/2024
CONNECTION FEES ¤1,187.26 12/10/2024
FC IMPACT FEE EMS ¤62.00 12/10/2024
IMPACT FEE FIRE ¤434.51 12/10/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/10/2024
FC IMPACT FEE LIBRARY ¤268.00 12/10/2024
IMPACT FEE PARKS ¤1,828.01 12/10/2024
IMPACT FEE SCHOOL ¤5,450.00 12/10/2024
IMPACT FEE TRANSPORTATION ¤1,862.00 12/10/2024
WATER -IRRIGATION INSPECTION ¤25.00 12/10/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,606.99