Permit #2024110635
Permit Details
Status: COED
| Parcel Id: 07-11-31-7022-00020-0010 |
| Block: 00020 |
| Subdivision: 7022 - |
| Job Phone: 813-540-8807 |
| Location Address: 16 WEISS PL |
| Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC |
| Issue Date: 11/14/2024 |
| NOC: RECORDED |
| Applicant name: DANIEL JAY GAWRYCH |
| Owner: BEXLEY THOMAS W & STACY S H&W |
|
Address 16 WEISS PLACE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤56,833.00 |
| Job Description: installation of solar pv modules on roof of residence |
| Type: CN |
Contractor
LUNEX POWER INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4721 N GRADY AVE TAMPA, FL 33614 |
CVC57085 (Exp: 08/31/2026) | 813-540-8807 |
Inspection History
| Type | Request Date | Result | Inspector |
| SOLAR ELECTRIC FINAL | 02/14/2025 | FINAL APPROVED | RMARTIN |
| Note: 1/28/2025 - PREVIOUS INSPECTION NOTES 1/28/25 1. Repair not made met with contractor on site FBCR 324.6 1/14/2025 - PREVIOUS INSPECTION NOTES 1/14/25 1. Fireset backs STILL not met per plans 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Panel layout does not match what is installed FBCR 324.6 2. Support panel wiring under panels off roof decking 3. Fire set backs not met per plans FBCR 324.6 12/12/2024 - PREVIOUS INSPECTION NOTES 12/12/24 Not ready 12/11/2024 - PREVIOUS INSPECTION NOTES 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** | |||
| SOLAR ELECTRIC FINAL | 01/28/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1/28/25 1. Repair not made met with contractor on site FBCR 324.6 1/14/2025 - PREVIOUS INSPECTION NOTES 1/14/25 1. Fireset backs STILL not met per plans 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Panel layout does not match what is installed FBCR 324.6 2. Support panel wiring under panels off roof decking 3. Fire set backs not met per plans FBCR 324.6 12/12/2024 - PREVIOUS INSPECTION NOTES 12/12/24 Not ready 12/11/2024 - PREVIOUS INSPECTION NOTES 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** | |||
| SOLAR ELECTRIC FINAL | 01/14/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1/14/25 1. Fireset backs STILL not met per plans 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Panel layout does not match what is installed FBCR 324.6 2. Support panel wiring under panels off roof decking 3. Fire set backs not met per plans FBCR 324.6 12/12/2024 - PREVIOUS INSPECTION NOTES 12/12/24 Not ready 12/11/2024 - PREVIOUS INSPECTION NOTES 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** | |||
| SOLAR ELECTRIC FINAL | 12/31/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 12/31/24 1. Panel layout does not match what is installed FBCR 324.6 2. Support panel wiring under panels off roof decking 3. Fire set backs not met per plans FBCR 324.6 12/12/2024 - PREVIOUS INSPECTION NOTES 12/12/24 Not ready 12/11/2024 - PREVIOUS INSPECTION NOTES 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** | |||
| SOLAR ELECTRIC FINAL | 12/12/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/12/24 Not ready 12/11/2024 - PREVIOUS INSPECTION NOTES 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** | |||
| SOLAR ELECTRIC FINAL | 12/11/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Need a full set of plans on site with City stamp of approval from Building Dept. FBC 107.3.1 *** 1 set on site was printed on to small of a sheet of paper and cut part of the plans off and no stamp, 2nd set of prints are wet*** |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/30/2025 | 01/31/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/06/2025 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/06/2025 | 01/06/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/06/2025 | 01/06/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/17/2024 | 12/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/17/2024 | 12/17/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/17/2024 | 12/17/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/13/2024 | 11/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/13/2024 | 11/14/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/13/2024 | 11/13/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/15/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/30/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/11/2024 |
| SURCHARGE FS 533.721 | ¤2.27 | 11/14/2024 |
| SURCHARGE - FS 468.631 | ¤3.40 | 11/14/2024 |
| ADJUSTMENT 10% | (¤25.18) | 11/14/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/14/2024 |
| INSPECTION - RESIDENTIAL | ¤156.75 | 11/14/2024 |
| SOLAR PLAN REVIEW | ¤65.00 | 11/14/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤352.24 |