I want to search for...

Permit #2024110964

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7035-01390-0120
Block: 01390
Subdivision: 7035 -
Job Phone: 386-216-9945
Location Address: 5 BILTVUE PL
Type: PO - POOL
Issue Date: 12/10/2024
NOC: RECORDED
Applicant name: CASEY C WATSON
Owner: ALBERT ANNE D & PHILLIP T H&W

Address

5 BILTVUE PLACE

PALM COAST, FL 32137

Lot: 0120
Contracted Stated Job Value: ¤90,939.00
Job Description: CONCRETE SWIMMING POOL WITH SCREEN ENCLOSURE
Type: CN

Contractor

EXQUISITE POOL & SPA INC
Status Location Address State License Number Phone
ACTIVE

3895 BRITTING DR

DELAND, FL 32724

CPC1457932 (Exp: 08/31/2026) 386-216-9945

Sub Contractors

JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503
JOHN LEROY HODGINS
Status Location Address State License Number Phone Fax
ACTIVE

2020 COUNTRY FARMS RD

PORT ORANGE, FL 32128

CGC1507254 (Exp: 08/31/2026) 386-547-2998 386-788-4028

Inspection History

Type Request Date Result Inspector
POOL FINAL 06/12/2025 FINAL APPROVED FWILLIS
U -UTILITY RESIDENTIAL FINAL 06/09/2025 FINAL APPROVED DHANEY
ROW- PROJECT STATUS 06/06/2025 Status Check EMADISON
Note: ** 06/06/25 SITE MEET FOR GRADE (RIGHT REAR CORNER) OFF POOL STRUCTURE AREA WAS LOW ON FINAL SURVEY/ AREA LOOKS GOOD WATER WILL FLOW TO THE FRONT AS INTENDED
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/06/2025 APPROVED EMADISON
Note: ** 06/06/25THE DRAINAGE WILL WILL WORK WATER WILL FLOW AS INTENDED FROM THE REAR TO THE FRONT ___________________________________________________________________________________________________________________
ROW FIELD SURVEY /GRADING CERTIFICATION 06/06/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 06/06/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PROJECT STATUS 05/29/2025 Status Check EMADISON
Note: ** 05/29/25 MET BUILDER AND HOMEOWNER DISCUSS WHAT NEEDS TI BE CHANGED IN ORDER FOR THE DRAINAGE TO FLOW
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/23/2025 Disapproved - NO FEE EMADISON
Note: ** 05/23/25 LEFT REAR CORNER OFF POOL STRUCTURE IS LOW WILL HOLD WATER AND FLOW UNDER FENCE CAUSING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY ON THE LEFT SIDE ** 6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement.Section 300.01 C(6) V-16 ** "Final Survey. The Final Survey is used to verify compliance with the Topographic Survey, Lot Grading Plan and Swale Plan.(1) A Final Survey must be submitted in person or uploaded online. If the survey is incomplete, unclear, does not adequately show the drainage patterns, or if the constructed drainage is incorrect, it will be disapproved until corrections are made and resubmitted for review and approval. Once any required field changes have been made and the survey has been revised, the contractor shall submit one (1) signed and sealed revised survey for review. If the field changes and/or the revised survey is accepted, a final inspection may be scheduled by the contractor. Section 300.01 F(1) V-17" ** NEED TO HAVEA POSITVE FLOW FROM THE REAR TO FRONT FOR STORMWATER ** 4) Positive fall is considered to be 0.10 of a foot every 20 feet. Section 300.01 D(4) V-17
ELECTRIC AND ALARM 04/25/2025 APPROVED JSTEWART
POOL DECK 02/19/2025 APPROVED FWILLIS
Note: POOL DECK ONLY!! PLEASE NOTE: PERGOLA MUST HAVE A SEPARATE PERMIT.
STEEL AND GROUND 01/07/2025 APPROVED FWILLIS

Review History

Department Status Date In Date Out
ZON COMPLETE 06/11/2025 06/11/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 06/11/2025 06/11/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 03/12/2025 03/19/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Pergola needs to be on separate permit
BADMIN INFORMATION 03/12/2025 03/12/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please see the 'document submittal requirements' and rename your files in accordance.
SW1 COMPLETE 03/12/2025 03/12/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/12/2025 03/12/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please apply for a pergola permit seperately.
SW1 COMPLETE 12/10/2024 12/10/2024
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 12/10/2024 12/10/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 11/19/2024 11/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 11/19/2024 11/21/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/19/2024 11/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/19/2024 11/25/2024
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE FLOW ARROWS OR PROPOSED NUMBERS FOR THE NEW GRADING OF THE LOT AFTER POOL IS DONE
ZON COMPLETE 11/19/2024 11/20/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤26.10) 12/10/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/10/2024
INSPECTION- POOL ¤160.00 12/10/2024
PLAN REVIEW - RESIDENTIAL ¤70.98 12/10/2024
SURCHARGE FS 533.721 ¤2.35 12/10/2024
SURCHARGE - FS 468.631 ¤3.52 12/10/2024
SW ENG INSPECTION 40 ¤40.00 12/10/2024
SW ENG - REVIEW 20 ¤20.00 12/10/2024
SITE PLAN 30 ¤30.00 12/10/2024
Fees Total Due: ¤0.00 Total Paid: ¤330.75