I want to search for...

Permit #2024111155

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00050-0110
GARAGE: 566 sqft
SCREEN PORCH (SOLID ROOF) : 292 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
CONDITIONED SPACE: 2400 sqft
Total Square Footage: 3316 sqft
Block: 00050
Subdivision: -
Job Phone: 386-283-2035
Location Address: 21 COLUMBIA LN
Type: DU - DUPLEX
Issue Date: 12/26/2024
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: WOLF JOHN & MARIA H&W

Address

8 SUNRISE CIRCLE

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
SERGEY A VORONIN
Status Location Address State License Number Phone
ACTIVE

7631 SEVERN

JACKSONVILLE, FL 32224

EC13011326 (Exp: 08/31/2026) 360-798-2819
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/15/2025 APPROVED CVANSTRAHLEN
Note:
U-CROSS CONNECTION 07/14/2025 APPROVED DHANEY
BLD - BUILDING FINAL 07/14/2025 Disapproved - NO FEE JSTEWART
Note: 1. Please label main disconnects with unit. 2. Please check all exterior Receptacles required Weather Resistant listing. Side A: 1. Please seal garage ceiling penetrations. 2. Please seal wall penetration in AHU closet. 3. Please tighten Anchors at header height at garage door bucks. per plan Side B: 1. Please seal garage ceiling penetrations. 2. Please seal wall penetration in AHU closet. 3. Please install Anchors at header height (cut off) at garage door bucks. per plan
U -UTILITY RESIDENTIAL FINAL 07/14/2025 FINAL APPROVED DHANEY
ROW - FINAL INSPECTION 07/11/2025 APPROVED - AS NOTED PFLANAGAN
Note: PLEASE CLEAN ALL DIRT FROM CULVERT PIPE
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/11/2025 APPROVED PFLANAGAN
Note: CORRECTION MADE TO FINAL SURVEY ------------------------------------------------------------------------ 7/7/2025 - PREVIOUS INSPECTION NOTES LEFT SIDE DRAINAGE PATTERN STATES THAT YOU DON'T HAVE POSITIVE FALL FINAL SURVEY STATES YOU GO FROM A 11.20 TO A 11.50.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/11/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - FINAL APRON (AFTER POUR) 07/11/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/07/2025 Disapproved - NO FEE PFLANAGAN
Note: LEFT SIDE DRAINAGE PATTERN STATES THAT YOU DON'T HAVE POSITIVE FALL FINAL SURVEY STATES YOU GO FROM A 11.20 TO A 11.50.
ROW- PROJECT STATUS 06/09/2025 Status Check EMADISON
Note: ** 06/09/25 SITE MEET WITH BUILDER REGARDING NATURAL AREA AT REAR OF PROPERTY ALSO PRESENT ONSITE G. BERTOLA, AND P. FLANAGAN
ROW- PROJECT STATUS 06/06/2025 Status Check EMADISON
Note: ** 06/06/25 MET ON SITE WITH BUILDER AREA BEYOND PROPERTY LINE HAS BEEN LEF NATURAL WATER WILL FLOW FROM REAR TO THE FRONT AS NOTED ON THE REVISED STE PLAN
ROW - DRAINAGE 05/23/2025 APPROVED - AS NOTED EMADISON
Note: ** 05/23/25 CORRECTIONS HAVE BEEN MADE ** IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE DRAINAGE, SEDIMENT AND EROSION CONTROL OF THE JOB SITE THROUGH OUT THE PROJECT SO AS NOT TO HAVE A NEGATIVE IMPACT ON ANY ADJACENT PROPERTIES OR THE ROADWAY _____________________________________________________________________________________________________________________ 5/19/2025 - PREVIOUS INSPECTION NOTES ** 05/25 BUILDER CONTACTED THIS INSPECTOR REQUESTED UNTIL 05/23/25 TO GET FILTER SOCK TO PROTECT DRAINAGE BASIN INLET. IF NOT CORRECTED AT THE TIME OF THE NEXT INSPECTION YOUR PERMIT WILL BE PLACED ON AN INSPECTION HOLD UNTIL ALL REQUIRED CORRECTIONS HAVE BEEN MADE AS NOTED IN PREVIOUS INSPECTIONS. SEE ALL NOTES ** REPLAIR ALL SILT FENCE AROUND SITE ** BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** FOLLOW UP INSPECTION ON 05/23/25 ______________________________________________________________________________________________________________________ 5/15/2025 - PREVIOUS INSPECTION NOTES ** 05/15/25 NO CORRECTIONS HAVE BEEN MADE AS NOTED IN PREVIOUS INSPECTION BUILDER WILL HAVE UP TO 05/20/25 TO MAKE ALL CORRECTIONS NOTED IF ALL CORRECTIONS HAVE NOT BEEN COMPLETED YOUR PERMIT WILL BE PLACED ON AN INSPECTION HOLD PRIORITY (1) STATUS IN ADDITION TO THE PREVIOUS CORRECTIONS NEEDED YOU ARE REQUIRED TO: ** REPLAIR ALL SILT FENCE AROUND SITE ** BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** FOLLOW UP INSPECTION ON 05/20/25 ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 05/15/25
ROW - DRAINAGE 05/20/2025 Disapproved - NO FEE EMADISON
Note: ** 05/25 BUILDER CONTACTED THIS INSPECTOR REQUESTED UNTIL 05/23/25 TO GET FILTER SOCK TO PROTECT DRAINAGE BASIN INLET. IF NOT CORRECTED AT THE TIME OF THE NEXT INSPECTION YOUR PERMIT WILL BE PLACED ON AN INSPECTION HOLD UNTIL ALL REQUIRED CORRECTIONS HAVE BEEN MADE AS NOTED IN PREVIOUS INSPECTIONS. SEE ALL NOTES ** REPLAIR ALL SILT FENCE AROUND SITE ** BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** FOLLOW UP INSPECTION ON 05/23/25 ______________________________________________________________________________________________________________________ 5/15/2025 - PREVIOUS INSPECTION NOTES ** 05/15/25 NO CORRECTIONS HAVE BEEN MADE AS NOTED IN PREVIOUS INSPECTION BUILDER WILL HAVE UP TO 05/20/25 TO MAKE ALL CORRECTIONS NOTED IF ALL CORRECTIONS HAVE NOT BEEN COMPLETED YOUR PERMIT WILL BE PLACED ON AN INSPECTION HOLD PRIORITY (1) STATUS IN ADDITION TO THE PREVIOUS CORRECTIONS NEEDED YOU ARE REQUIRED TO: ** REPLAIR ALL SILT FENCE AROUND SITE ** BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** FOLLOW UP INSPECTION ON 05/20/25 ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 05/15/25
ROW- PRE-APRON (PRE-POUR) 05/20/2025 APPROVED FSLADISH
Note: 5/20/25 READY TO LAY PAVERS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________ 5/15/2025 - PREVIOUS INSPECTION NOTES ** 05/15/25 CORRECTIONS MADE ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ________________________________________________________________________________________________________________ 5/14/2025 - PREVIOUS INSPECTION NOTES ** 05/14/25 RIGHT SIDE CULVERT IS TWISTED AND NOT INSTALLED FLAT BUILDER NEEDS TO STRAIGHTEN THE CULVERT ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 ENTIRE POUR AREA TOO WET WATER FLOWING INTO POUR AREA. ** SEE ATTACHED PHOTOS
ROW- PAVER RESTRAINTS 05/15/2025 APPROVED - AS NOTED EMADISON
Note: ** 05/15/25 ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
ROW- PRE-APRON (PRE-POUR) 05/15/2025 PARTIALLY APPROVED EMADISON
Note: ** 05/15/25 CORRECTIONS MADE ** APRON READY TO POUR WITH PAVER RESTRAINT ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED ________________________________________________________________________________________________________________ 5/14/2025 - PREVIOUS INSPECTION NOTES ** 05/14/25 RIGHT SIDE CULVERT IS TWISTED AND NOT INSTALLED FLAT BUILDER NEEDS TO STRAIGHTEN THE CULVERT ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 ENTIRE POUR AREA TOO WET WATER FLOWING INTO POUR AREA. ** SEE ATTACHED PHOTOS
ROW - DRAINAGE 05/15/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/15/25 NO CORRECTIONS HAVE BEEN MADE AS NOTED IN PREVIOUS INSPECTION BUILDER WILL HAVE UP TO 05/20/25 TO MAKE ALL CORRECTIONS NOTED IF ALL CORRECTIONS HAVE NOT BEEN COMPLETED YOUR PERMIT WILL BE PLACED ON AN INSPECTION HOLD PRIORITY (1) STATUS IN ADDITION TO THE PREVIOUS CORRECTIONS NEEDED YOU ARE REQUIRED TO: ** REPLAIR ALL SILT FENCE AROUND SITE ** BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** FOLLOW UP INSPECTION ON 05/20/25 ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 05/15/25
ROW- PRE-APRON (PRE-POUR) 05/14/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/14/25 RIGHT SIDE CULVERT IS TWISTED AND NOT INSTALLED FLAT BUILDER NEEDS TO STRAIGHTEN THE CULVERT ____________________________________________________________________________________________________________________ 5/12/2025 - PREVIOUS INSPECTION NOTES ** 05/12/25 ENTIRE POUR AREA TOO WET WATER FLOWING INTO POUR AREA. ** SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/12/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/12/25 ENTIRE POUR AREA TOO WET WATER FLOWING INTO POUR AREA. ** SEE ATTACHED PHOTOS
ROW - DRAINAGE 05/12/2025 Disapproved - NO FEE EMADISON
Note: ** 05/12/25 BUILDER NEEDS TO INSTALL DRAINAGE PROTECTION AROUND THE CATCH BASIN ON THE RIGHT SIDE IN SWALE TO PREVENT THE EROSION OF SEDIMENT AND OTHER DEBRIS INTO THE STORMWATER SYSTEM ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 05/15/25
ELECTRIC - EARLY POWER 05/01/2025 APPROVED - AS NOTED HCAMACHO
Note: Outdoor Outlets need to be WR. What is currently installed is TR. NEC 406.9(B)(1)
FIREWALL FINAL 04/11/2025 APPROVED HCAMACHO
Note:
FIREWALL DRYWALL NAILING 04/07/2025 APPROVED - AS NOTED JSTEWART
Note: Inspector Notes from Inspection 2490 Energy Calcs were submitted for revision of R5 insulation on block wall.
INSULATION 04/03/2025 APPROVED - AS NOTED HCAMACHO
Note: Energy Calcs were submitted for revision of R5 insulation on block wall.
GRAVITY SEWER TEST 03/31/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 WATEWR SERVICE NOT RAN THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 03/31/2025 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 WATEWR SERVICE NOT RAN THIS WAS A VIRTUAL INSPECTION
INSULATION 03/26/2025 Disapproved - NO FEE HCAMACHO
Note: 1. 3/4" R5 Insulation board installed on block wall and partition wall. Energy calcs call for R6. Energy calcs need to be revised because it could affect type of equipment and other things installed. * This was mentioned at Rough inspection. See Notes from Rough inspection.*
LATH/BRICK/ WATER BARRIER 03/19/2025 APPROVED HCAMACHO
ALL ROUGH 03/19/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. (3) A/C boots in side B need gasket/seal.R402.4.1.1 2. Move Smoke detector in living room outside master away from Fan blades 3'. NFPA 72 SMOKE DETECTORS NEED TO BE 3` FROM FAN BLADES AND A/C VENT 3. Need to Fire caulk pipe for service passing throug Fire Wall both sides.FBC EC R402.4.5 4. All bath Fans need second mechanical attachemnt.FBCR M1604.4.1 5. Move outlet in kitchen wall to make sure it is over the peninsula counter so it counts for counter space.NEC 210.52 Note- Doing Blown insulation. Energy Calcs calls for R6 on block walls, but only R5 is installed. Please Revise for insulation Inspection.
FIREWALL FINAL 03/12/2025 PARTIALLY APPROVED HCAMACHO
Note: The wall above the ceiling is ok. Need to sheetrock bottom wall.
FIREWALL DRYWALL NAILING 03/05/2025 APPROVED HCAMACHO
ROOF VALLEY & METAL 03/04/2025 APPROVED HCAMACHO
FIREWALL FRAMING 03/03/2025 APPROVED HCAMACHO
WALL SHEATHING 02/25/2025 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/25/2025 APPROVED FWILLIS
TIE BEAM / LINTEL 02/14/2025 APPROVED BTAYLOR
TIE BEAM / LINTEL 02/13/2025 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 02/06/2025 APPROVED TBAKER
MONOLITHIC SLAB 01/23/2025 APPROVED HCAMACHO
PLUMBING 1ST ROUGH UNDERGROUND 01/21/2025 APPROVED - AS NOTED MGIBSON
Note: WATEWR SERVICE NOT RAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/17/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/03/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 05/29/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SW1 COMPLETE 05/29/2025 06/02/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved contigent on final survey to ensure changes to property line on left side does not negative impact lot 10'.
ZON COMPLETE 05/29/2025 05/29/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 04/02/2025 04/03/2025
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON HOLD 04/01/2025 04/01/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM This property is deeded in a trust. You must submit the correct Right of Way Utilization Agreement for Paver Driveways for properties deeded in a trust. The Agreement must be filled out completely and once the correct form is complete, please submit the Agreement electronically for staff review.
SW1 COMPLETE 04/01/2025 04/04/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2025 04/04/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON HOLD 04/01/2025 04/01/2025
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM This property is deeded in a trust. You must submit the correct Right of Way Utilization Agreement for Paver Driveways for PROPERTIES DEEDED IN A TRUST (THIS IS A DIFFERENT AGREEMENT THAN YOU SUBMITTED - THE ONE YOU USED WAS FOR PROPERTIES NOT DEEDED IN A TRUST). The Agreement must be filled out completely and once the correct form is complete, please submit the Agreement electronically for staff review.
MECH COMPLETE 03/27/2025 03/28/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2025 03/21/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/11/2025 03/11/2025
Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 03/11/2025 03/17/2025
Note: Held By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM Per Gabriel, drainage in the back pass the natural buffer needs to flow to the front of property and not towards the Parkway.
ZON HOLD 03/11/2025 03/11/2025
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please fillout the correct right away agreement with the trust as John and Maria are trustees for the trust and the home is in the name of the trust
ENGIN1 COMPLETE 02/05/2025 02/06/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/05/2025 02/05/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/14/2025 01/17/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 12/23/2024 12/23/2024
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 12/18/2024 12/18/2024
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment LANDSCAPE PLAN IS MISSING ONE TREE. THIS LOT SIZE REQUIRES 5 TREES
CUSVC COMPLETE 12/18/2024 12/20/2024
Note: Released By: PAMELA MILLER - -
MECH COMPLETE 12/18/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 12/18/2024 12/19/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/18/2024 12/19/2024
Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM
SWALE COMPLETE 11/25/2024 12/16/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 11/25/2024 11/25/2024
Note: Held By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM LANDSCAPE PLAN IS MISSING ONE TREE. THIS LOT SIZE REQUIRES 5 TREES.
BADMIN COMPLETE 11/22/2024 12/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/22/2024 12/03/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC HOLD 11/22/2024 11/27/2024
Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please correct the utility application to reflect the correct property address
ELEC COMPLETE 11/22/2024 12/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/22/2024 11/25/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/22/2024 12/02/2024
LOCATE COMPLETE 11/22/2024 12/02/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 11/22/2024 12/02/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy calcs and state cards need to be signed by the builders 2. State card needs to have a file name of state card
SW1 HOLD 11/22/2024 12/11/2024
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Common swales are preferred and can be achieved with the existing grades, please review and revise the inside swales on both the right and the left sides. Please show type of construction, either concrete block or wood frame. Culvert for Lot 12 needs to be shown.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG - INSPECTION 20 ¤20.00 07/11/2025
SW ENG - INSPECTION 20 ¤20.00 05/16/2025
SW ENG REINSPECTION 30 ¤30.00 05/16/2025
RECORDING FEE REIMBURSE DOC ¤44.00 03/11/2025
IMPACT FEE TRANSPORTATION ¤2,890.00 12/26/2024
SURCHARGE FS 533.721 ¤14.95 12/26/2024
SURCHARGE - FS 468.631 ¤22.42 12/26/2024
SW ENG - FOUNDATION SURVEY ¤20.00 12/26/2024
SW ENG INSPECTION 80 ¤80.00 12/26/2024
SW ENG PRE APRON ¤30.00 12/26/2024
ADJUSTMENT 10% (¤166.09) 12/26/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/26/2024
INSPECTION - RESIDENTIAL ¤1,270.50 12/26/2024
PLAN REVIEW - RESIDENTIAL ¤360.36 12/26/2024
FC IMPACT FEE EMS ¤124.00 12/26/2024
IMPACT FEE FIRE ¤869.02 12/26/2024
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 12/26/2024
FC IMPACT FEE LIBRARY ¤536.00 12/26/2024
IMPACT FEE PARKS ¤3,656.02 12/26/2024
IMPACT FEE SCHOOL ¤3,600.00 12/26/2024
SW ENG - REVIEW 20 ¤20.00 12/26/2024
SW ENG RES REVIEW 200 ¤200.00 12/26/2024
SITE PLAN 30 ¤30.00 12/26/2024
SEWER CREDIT (¤1,147.00) 12/26/2024
SEWER INSPECTION ¤25.00 12/26/2024
SEWER CAPITAL FACILITY ¤12,241.04 12/26/2024
WATER CAPITAL FACILITY FEE ¤8,702.28 12/26/2024
CONNECTION FEES ¤2,374.52 12/26/2024
WATER- TURN ON ¤50.00 12/26/2024
WATER -IRRIGATION INSPECTION ¤50.00 12/26/2024
Fees Total Due: ¤0.00 Total Paid: ¤36,433.02