Permit #2024111287

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-0540
CONDITIONED SPACE: 2805 sqft
GARAGE: 762 sqft
OPENED PORCH (WITH ROOF) : 292 sqft
OPENED PORCH (WITH ROOF) : 37 sqft
Total Square Footage: 3896 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-237-0328
Location Address: 681 MAHOGANY RUN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/13/2024
NOC: RECORDED
Applicant name: JAMES JOSEPH ALBANO
Owner: COLALUCA TANYA M TRUSTEE

Address

102 ISLAND ESTATES PARKWAY

PALM COAST, FL 32137

Lot: 0540
Contracted Stated Job Value: ¤450,000.00
Job Description: Two-Story Single Family Residence
Type: CN

Contractor

ALBANO DESIGNS STUDIOS, INC
Status Location Address State License Number Phone
ACTIVE

82 LEE DR

PALM COAST, FL 32137

CBC050078 (Exp: 08/31/2026) 386-237-0328

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
ROBERTO F GONZALEZ
Status Location Address State License Number Phone
ACTIVE

212 PALMETTO AVE

CRESCENT CITY, FL 32112

RF11067887 (Exp: 08/31/2027) 286-559-2885
SHAWN MICHAEL HISS
Status Location Address State License Number Phone
ACTIVE

1315 LPGA BLVD

HOLLY HILL, FL 32117

CAC1813585 (Exp: 08/31/2026) (386)672-8688
SCOTT DALE CRIDER
Status Location Address State License Number Phone
ACTIVE

PO BOX 353092

PALM COAST, FL 32137

CCC1333991 (Exp: 08/31/2026) 386-276-0758

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 09/09/2025 APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 09/08/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 09/08/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 09/08/2025 FINAL APPROVED BHAINES
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/05/2025 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 09/05/2025 APPROVED - AS NOTED EMADISON
Note: ** 09/05/25 BUILDER NEEDS TO LAY SOD ALONG BOTH PROPERTY LINE LEFT AND RIGHT IN THE DRAINAGE CONVEYANCE TO PREVENT BARK MULCH FROM WASHING OUT AS IT HAS DONE ON THE LEFT SIDE ** BEFORE THE ROW STORMWATER FINAL BUILDER NEEDS TO RAISE ALL POP-UP DRAINS SO THEY ARE ON TOP OF THE SOD NOT BELOW AS THIS WILL WASHOUT UNDERNEATH THE SOD ** SOD NEEDS TO BE BEHIND THE CURB AND GUTTER AT ROADSIDE NOT SET OVER CURB AND GUTTER
BLD - BUILDING FINAL 09/05/2025 FINAL APPROVED JSTEWART
Note: 8/29/2025 - PREVIOUS INSPECTION NOTES 1. Need SPD outside at service.NEC 230.67 2. Need to seal attic access in garage or install attic stairs.R302.5 3. Need to revise Energy Calcs for A/C Equipment.FBC [A] 107.4 4. Seal cealing around ducts in the A/C closet.
BLD - BUILDING FINAL 08/29/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Need SPD outside at service.NEC 230.67 2. Need to seal attic access in garage or install attic stairs.R302.5 3. Need to revise Energy Calcs for A/C Equipment.FBC [A] 107.4 4. Seal cealing around ducts in the A/C closet.
ROW- PRE-APRON (PRE-POUR) 07/29/2025 APPROVED PFLANAGAN
Note: READY FOR PAVERS ----------------------------------------------------------------------------- 7/23/2025 - PREVIOUS INSPECTION NOTES ** 07/23/25 READY TO POUR APRON AND PAVER RESTRAINTS ** APRON READY TO POUR WITH PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED _____________________________________________________________________________________________________________________ 7/22/2025 - PREVIOUS INSPECTION NOTES ** 07/22/25 APRON FILLED WITH WATER
ROW- PAVER RESTRAINTS 07/23/2025 APPROVED EMADISON
Note: ** 07/23/25 ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE _________________________________________________________________________________________________________________ 7/22/2025 - PREVIOUS INSPECTION NOTES ** 07/22/25 PAVER RESTRAINTAT TOP OF DRIVEWAY FILLED WITH WATER
ROW- PRE-APRON (PRE-POUR) 07/23/2025 PARTIALLY APPROVED EMADISON
Note: ** 07/23/25 READY TO POUR APRON AND PAVER RESTRAINTS ** APRON READY TO POUR WITH PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED _____________________________________________________________________________________________________________________ 7/22/2025 - PREVIOUS INSPECTION NOTES ** 07/22/25 APRON FILLED WITH WATER
ROW- PRE-APRON (PRE-POUR) 07/22/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/22/25 APRON FILLED WITH WATER
ROW- PAVER RESTRAINTS 07/22/2025 Disapproved - NO FEE EMADISON
Note: ** 07/22/25 PAVER RESTRAINTAT TOP OF DRIVEWAY FILLED WITH WATER
ELECTRIC - EARLY POWER 07/18/2025 APPROVED HCAMACHO
GRAVITY SEWER TEST 07/15/2025 APPROVED - AS NOTED MGIBSON
Note: THIS IS APPROVED AS WELL AS SEWER TIE IN. " THIS IS NOT THE RESPONSIBILITY OF THE INSPECTOR"
SEWER TIE IN 07/15/2025 APPROVED MGIBSON
LATH/BRICK/ WATER BARRIER 06/17/2025 APPROVED HCAMACHO
Note: 4/21/2025 - PREVIOUS INSPECTION NOTES 2nd floor left side main wall to window bands only. Windows are not set do not cover till water barrier is approved within the window band detail. 4/15/2025 - PREVIOUS INSPECTION NOTES This is only a Partial inspection on the second floor Lath that is directly above the 1st floor roof. 4/14/2025 - PREVIOUS INSPECTION NOTES Not ready, Please cancel if the job is not ready for inspection. FBC (A)107.4
WINDOW NAILING 06/12/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 1. Need to seal kitchen duct to the roof.FBCR M1601.4.1 2. Kitchen duct missing screws at connections. FBCR M1601.4.1 3. Missing nail plates in laundry room water lines.FBCR P2603.2.1 4. No 5' head on plumbing. FBCR P2503.7 5. A/C layout needs to be revised. Different pipe sizes in several locations and different layout.FBC [A]107.4 6. Dryer vent needs correct nail plates.FBCR M1308.2 7. Several pipes are crushed and twisted especially the ones in the floor trusses down stairs. FBC M1301.3 8. A/C MISSING GASKETS ON BOOT/ REGISTER Upstairs R402.4.1.1 *Will check at Insualtion* Note- Missing all the windows and doors. Openings are covered with plastic. Will add a Window Nail inspection.
INSULATION 06/12/2025 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2420 1. Need to seal kitchen duct to the roof.FBCR M1601.4.1 2. Kitchen duct missing screws at connections. FBCR M1601.4.1 3. Missing nail plates in laundry room water lines.FBCR P2603.2.1 4. No 5' head on plumbing. FBCR P2503.7 5. A/C layout needs to be revised. Different pipe sizes in several locations and different layout.FBC [A]107.4 6. Dryer vent needs correct nail plates.FBCR M1308.2 7. Several pipes are crushed and twisted especially the ones in the floor trusses down stairs. FBC M1301.3 8. A/C MISSING GASKETS ON BOOT/ REGISTER Upstairs R402.4.1.1 *Will check at Insualtion* Note- Missing all the windows and doors. Openings are covered with plastic. Will add a Window Nail inspection.
ALL ROUGH 05/28/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. Need to seal kitchen duct to the roof.FBCR M1601.4.1 2. Kitchen duct missing screws at connections. FBCR M1601.4.1 3. Missing nail plates in laundry room water lines.FBCR P2603.2.1 4. No 5' head on plumbing. FBCR P2503.7 5. A/C layout needs to be revised. Different pipe sizes in several locations and different layout.FBC [A]107.4 6. Dryer vent needs correct nail plates.FBCR M1308.2 7. Several pipes are crushed and twisted especially the ones in the floor trusses down stairs. FBC M1301.3 8. A/C MISSING GASKETS ON BOOT/ REGISTER Upstairs R402.4.1.1 *Will check at Insualtion* Note- Missing all the windows and doors. Openings are covered with plastic. Will add a Window Nail inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/23/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. GB02 in the rear needs strapping. 2. B10 missing nails on strap. 3. Please check all tread, some are loose after loading the roof with tile.
LATH/BRICK/ WATER BARRIER 04/21/2025 PARTIALLY APPROVED JSTEWART
Note: 2nd floor left side main wall to window bands only. Windows are not set do not cover till water barrier is approved within the window band detail. 4/15/2025 - PREVIOUS INSPECTION NOTES This is only a Partial inspection on the second floor Lath that is directly above the 1st floor roof. 4/14/2025 - PREVIOUS INSPECTION NOTES Not ready, Please cancel if the job is not ready for inspection. FBC (A)107.4
LATH/BRICK/ WATER BARRIER 04/15/2025 PARTIALLY APPROVED HCAMACHO
Note: This is only a Partial inspection on the second floor Lath that is directly above the 1st floor roof. 4/14/2025 - PREVIOUS INSPECTION NOTES Not ready, Please cancel if the job is not ready for inspection. FBC (A)107.4
LATH/BRICK/ WATER BARRIER 04/14/2025 Disapproved -FEE REQUIRED MKRASKI
Note: Not ready, Please cancel if the job is not ready for inspection. FBC (A)107.4
ROOF VALLEY & METAL 04/01/2025 APPROVED HCAMACHO
WALL SHEATHING 04/01/2025 APPROVED HCAMACHO
ELECTRIC-TUG 03/07/2025 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 3/7/2025 9:49:10 AM *** 1. Post address prior to next inspection. FBCR 319.1 2. Authorize release of email to FPL.
TIE BEAM / LINTEL 02/24/2025 APPROVED HCAMACHO
FOUND SURVEY APPROVED (OFFICE) 02/13/2025 APPROVED TBAKER
MONOLITHIC SLAB 02/03/2025 APPROVED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 2/3/2025 12:41:08 PM *** A revision to foundation Plan was submitted and approved for Previous mentioned Notes. 1/29/2025 - PREVIOUS INSPECTION NOTES 1. Footers in Garage, front entry and lanai not per plans. Marked on plan.FBC [A]107.4
MONOLITHIC SLAB 01/29/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Footers in Garage, front entry and lanai not per plans. Marked on plan.FBC [A]107.4
PLUMBING 1ST ROUGH UNDERGROUND 01/21/2025 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 12/16/2024 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 09/04/2025 09/04/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 08/28/2025 08/28/2025
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Missing Blower Door
BLD COMPLETE 06/11/2025 06/18/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 06/11/2025 06/13/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/20/2025 05/22/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/13/2025 02/13/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/13/2025 02/13/2025
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2025 01/31/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 01/29/2025 01/31/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plan has to have a digital verifiable signature F.S. 471.025
BLD COMPLETE 12/13/2024 12/13/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 11/27/2024 12/06/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 11/27/2024 12/06/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Florida product approval revision for underlayment is expired. revise roofing worksheet 2. Provide completed City of Palm Coast product approval worksheet
CUSVC COMPLETE 11/27/2024 12/03/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 11/27/2024 12/09/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/27/2024 12/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 11/27/2024 12/05/2024
LOCATE COMPLETE 11/27/2024 12/04/2024
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 11/27/2024 12/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 11/27/2024 12/13/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM
ZON COMPLETE 11/27/2024 11/27/2024
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
URB COMPLETE 11/27/2024 12/02/2024
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/08/2025
SW ENG REINSPECTION 30 ¤30.00 09/08/2025
REINSPECTION RESIDENTIAL ¤40.00 05/20/2025
CONNECTION FEES ¤25.00 12/13/2024
FC IMPACT FEE EMS ¤62.00 12/13/2024
IMPACT FEE FIRE ¤434.51 12/13/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/13/2024
FC IMPACT FEE LIBRARY ¤268.00 12/13/2024
IMPACT FEE PARKS ¤1,828.01 12/13/2024
IMPACT FEE SCHOOL ¤5,450.00 12/13/2024
IMPACT FEE TRANSPORTATION ¤3,404.00 12/13/2024
SURCHARGE FS 533.721 ¤17.46 12/13/2024
SURCHARGE - FS 468.631 ¤26.19 12/13/2024
SW ENG - FOUNDATION SURVEY ¤20.00 12/13/2024
SW ENG INSPECTION 80 ¤80.00 12/13/2024
SW ENG PRE APRON ¤30.00 12/13/2024
SW ENG - REVIEW 20 ¤20.00 12/13/2024
SW ENG RES REVIEW 200 ¤200.00 12/13/2024
SEWER INSPECTION ¤25.00 12/13/2024
SITE PLAN 30 ¤30.00 12/13/2024
WATER-METER ¤514.49 12/13/2024
ADJUSTMENT 10% (¤193.97) 12/13/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/13/2024
INSPECTION - RESIDENTIAL ¤1,487.75 12/13/2024
PLAN REVIEW - RESIDENTIAL ¤421.98 12/13/2024
Fees Total Due: ¤0.00 Total Paid: ¤14,500.92