I want to search for...
Permit #2024120007
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7015-00020-1100 |
| Block: 00020 |
| Subdivision: 7015 - |
| Job Phone: 386-503-0666 |
| Location Address: 11 CRAZY HORSE CT |
| Type: DR - DRIVEWAY |
| Issue Date: 12/09/2024 |
| NOC: Unknown |
| Applicant name: ANTONIO M PAIVA |
| Owner: GAWESKI RAFAL & KRZYSZTOFA GAWESKA H&W |
|
Address 11 CRAZY HORSE COURT PALM COAST, FL 32137 |
| Lot: 1100 |
| Contracted Stated Job Value: ¤4,500.00 |
| Job Description: PAVER DRIVEWAY |
| Type: CN |
Contractor
AVANTI CONCRETE PUMPING INC
| Status | Location Address | Phone | Fax |
| ACTIVE |
PO BOX 351743 SATSUMA, FL 32189 |
386-503-0666 | 386-586-7687 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 02/12/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved. | |||
| ROW - FINAL INSPECTION | 02/12/2025 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection, all minimum city requirements were met. The builder's responsible for ensuring that nothing changes after this Inspection is approved. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/12/2025 | FINAL APPROVED | BWRIGHT |
| ROW- PRE-APRON (PRE-POUR) | 12/27/2024 | APPROVED | PFLANAGAN |
| Note: READY TO LAY PAVERS ------------------------------------------------------------------------- 12/19/2024 - PREVIOUS INSPECTION NOTES 12/19/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9270 ** 12/19/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED | |||
| ROW- PAVER RESTRAINTS | 12/19/2024 | APPROVED | EMADISON |
| Note: ** 12/19/24 READY TO POUR PAVER RESTRAINTS WITH APRON** 12/19/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE | |||
| ROW- PRE-APRON (PRE-POUR) | 12/19/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 12/19/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED | |||
| ROW- PRE-APRON (PRE-POUR) | 12/19/2024 | Disapproved - NO FEE | EMADISON |
| Note: Inspector Notes from Inspection 9270 ** 12/19/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED | |||
| ROW- PRE-APRON (PRE-POUR) | 12/19/2024 | PARTIALLY APPROVED | EMADISON |
| Note: 12/19/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9270 ** 12/19/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 12/06/2024 | 12/06/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/02/2024 | 12/05/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 12/02/2024 | 12/06/2024 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/02/2024 | 12/02/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤3.00) | 12/09/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/09/2024 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 12/09/2024 |
| SW ENG INSPECTION 40 | ¤40.00 | 12/09/2024 |
| SW ENG PRE APRON | ¤30.00 | 12/09/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/09/2024 |
| SITE PLAN 15 | ¤15.00 | 12/09/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤356.00 |