I want to search for...

Permit #2024120025

Permit Details

Status: COED

Parcel Id: 31-11-31-5145-00000-00A1
Subdivision: 2341 - PONCE PRESERVE SUBDIVISION
Job Phone: 904-781-7060
Location Address: 2 PONCE PRESERVE DR
Type: CFN - COMMERCIAL FENCE
Issue Date: 01/13/2025
NOC: RECORDED
Applicant name: DANIEL WILLIAM BUTTERWORTH
Owner: RICHMOND AMERICAN HOMES OF FLORIDA LP

Address

10255 FORTUNE PARKWAY SUITE 150

JACKSONVILLE, FL 32256

Contracted Stated Job Value: ¤150,000.00
Job Description: Summer Tide Entry Gates
Type: CN

Contractor

ALL WEATHER CONTRACTORS INC
Status Location Address State License Number Phone Fax
ACTIVE

1702 LINDSEY ROAD

JACKSONVILLE, FL 32221

CGC1523954 (Exp: 08/31/2026) 904-781-7060 904-619-5011

Sub Contractors

DEXTER GLENTON ALIE
Status Location Address State License Number Phone
INACTIVE

864 POYDRAS LN N

JACKSONVILLE, FL 32219

EC13009280 (Exp: 08/31/2026) 904-475-2961

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 07/15/2025 APPROVED RMARTIN
Note: 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25 Sent power to FPL, call back in when power is on to test gates 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made
FINAL 07/15/2025 FINAL APPROVED FWILLIS
FIRE FINAL 07/15/2025 APPROVED RMARTIN
LDSC- LANDSCAPE FINAL 05/09/2025 APPROVED RPICATAGI
ELECTRIC FINAL 05/09/2025 PARTIALLY APPROVED RMARTIN
Note: 5/9/25 Sent power to FPL, call back in when power is on to test gates 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made
ELECTRIC FINAL 04/22/2025 Disapproved - NO FEE RMARTIN
Note: 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made
ELECTRIC FINAL 04/09/2025 PARTIALLY APPROVED MKRASKI
Note: 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made
ELECTRIC FINAL 04/04/2025 Disapproved - NO FEE MKRASKI
Note: 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspectio n
ELECTRIC 1ST ROUGH 03/14/2025 APPROVED MKRASKI
DOWN CELL 02/14/2025 APPROVED FWILLIS
FOOTER 02/03/2025 APPROVED FWILLIS
Note: Entrance Gate Ponce DeLeon Drive side.

Review History

Department Status Date In Date Out
ELEC COMPLETE 05/07/2025 05/08/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 01/10/2025 01/10/2025
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM A note was added to the plan sheet therefor this has been resolved
PLLA COMPLETE 01/10/2025 01/10/2025
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM Landscape review and as-built to be reviewed and inspected under Site Development Permit
BLD COMPLETE 12/02/2024 12/09/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
DSD COMPLETE 12/02/2024 12/03/2024
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
PLLA HOLD 12/02/2024 12/09/2024
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide Landscape Plan
UD1 COMPLETE 12/02/2024 12/03/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
FI1 HOLD 12/02/2024 12/09/2024
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide information on the Knox Key Switch for rapid entry of fire department access into the community and location of Key Switch per NFPA 1, 18.2.2.1 and AHJ And place the following note on the cover sheet. Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤115.75) 01/13/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 01/13/2025
INSPECTION COMMERCIAL ¤1,050.00 01/13/2025
PLAN REVIEW - MISC 32.50 ¤32.50 01/13/2025
SURCHARGE FS 533.721 ¤10.42 01/13/2025
SURCHARGE - FS 468.631 ¤15.63 01/13/2025
SW ENG REVIEW- 40 ¤40.00 01/13/2025
SITE PLAN 15 ¤15.00 01/13/2025
Fees Total Due: ¤0.00 Total Paid: ¤1,122.80