I want to search for...
Permit #2024120025
Permit Details
Status: COED
| Parcel Id: 31-11-31-5145-00000-00A1 |
| Subdivision: 2341 - PONCE PRESERVE SUBDIVISION |
| Job Phone: 904-781-7060 |
| Location Address: 2 PONCE PRESERVE DR |
| Type: CFN - COMMERCIAL FENCE |
| Issue Date: 01/13/2025 |
| NOC: RECORDED |
| Applicant name: DANIEL WILLIAM BUTTERWORTH |
| Owner: RICHMOND AMERICAN HOMES OF FLORIDA LP |
|
Address 10255 FORTUNE PARKWAY SUITE 150 JACKSONVILLE, FL 32256 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: Summer Tide Entry Gates |
| Type: CN |
Contractor
ALL WEATHER CONTRACTORS INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1702 LINDSEY ROAD JACKSONVILLE, FL 32221 |
CGC1523954 (Exp: 08/31/2026) | 904-781-7060 | 904-619-5011 |
Sub Contractors
DEXTER GLENTON ALIE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
864 POYDRAS LN N JACKSONVILLE, FL 32219 |
EC13009280 (Exp: 08/31/2026) | 904-475-2961 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 07/15/2025 | APPROVED | RMARTIN |
| Note: 5/9/2025 - PREVIOUS INSPECTION NOTES 5/9/25 Sent power to FPL, call back in when power is on to test gates 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made | |||
| FINAL | 07/15/2025 | FINAL APPROVED | FWILLIS |
| FIRE FINAL | 07/15/2025 | APPROVED | RMARTIN |
| LDSC- LANDSCAPE FINAL | 05/09/2025 | APPROVED | RPICATAGI |
| ELECTRIC FINAL | 05/09/2025 | PARTIALLY APPROVED | RMARTIN |
| Note: 5/9/25 Sent power to FPL, call back in when power is on to test gates 4/22/2025 - PREVIOUS INSPECTION NOTES 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made | |||
| ELECTRIC FINAL | 04/22/2025 | Disapproved - NO FEE | RMARTIN |
| Note: 4/22/25 Plans call for a 100A MCB to be installed, there is not one installed.... Job needs to match the plan or the plan needs to match the job. FBC 107.4 4/9/2025 - PREVIOUS INSPECTION NOTES 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made | |||
| ELECTRIC FINAL | 04/09/2025 | PARTIALLY APPROVED | MKRASKI |
| Note: 4/4/2025 - PREVIOUS INSPECTION NOTES 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspection Emailed FPL @ 9:30am Call inspection back in once meter is set and revisions have been approved as well as repairs made | |||
| ELECTRIC FINAL | 04/04/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Elec. plans do not match what is installed, No MCB installed, Panel schdule does not match plans FBC (A)107.4 2. Can not locate Ground 2nd ground rod and ground rods not proper size per detail E1.1 NEC 250.53(A)(2) 3. Plans call for 1/0 copper grounding electrode conductor per note 2 per detail E1.1 FBC (A)107.4 Make all repairs before calling back in for re-inspectio n | |||
| ELECTRIC 1ST ROUGH | 03/14/2025 | APPROVED | MKRASKI |
| DOWN CELL | 02/14/2025 | APPROVED | FWILLIS |
| FOOTER | 02/03/2025 | APPROVED | FWILLIS |
| Note: Entrance Gate Ponce DeLeon Drive side. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 05/07/2025 | 05/08/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 01/10/2025 | 01/10/2025 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM A note was added to the plan sheet therefor this has been resolved | |||
| PLLA | COMPLETE | 01/10/2025 | 01/10/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM Landscape review and as-built to be reviewed and inspected under Site Development Permit | |||
| BLD | COMPLETE | 12/02/2024 | 12/09/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 12/02/2024 | 12/03/2024 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| PLLA | HOLD | 12/02/2024 | 12/09/2024 |
| Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide Landscape Plan | |||
| UD1 | COMPLETE | 12/02/2024 | 12/03/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 12/02/2024 | 12/09/2024 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide information on the Knox Key Switch for rapid entry of fire department access into the community and location of Key Switch per NFPA 1, 18.2.2.1 and AHJ And place the following note on the cover sheet. Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 10% | (¤115.75) | 01/13/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 01/13/2025 |
| INSPECTION COMMERCIAL | ¤1,050.00 | 01/13/2025 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 01/13/2025 |
| SURCHARGE FS 533.721 | ¤10.42 | 01/13/2025 |
| SURCHARGE - FS 468.631 | ¤15.63 | 01/13/2025 |
| SW ENG REVIEW- 40 | ¤40.00 | 01/13/2025 |
| SITE PLAN 15 | ¤15.00 | 01/13/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,122.80 |