I want to search for...
Permit #2024120035
Permit Details
Status: COED
| Parcel Id: 07-11-31-7033-00480-0250 |
| CONDITIONED SPACE: 1403 sqft |
| GARAGE: 478 sqft |
| OPENED PORCH (WITH ROOF) : 83 sqft |
| Total Square Footage: 1964 sqft |
| Block: 00480 |
| Subdivision: - |
| Job Phone: 386-586-6180 |
| Location Address: 13 RENN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/14/2025 |
| NOC: RECORDED |
| Applicant name: FLAGLER HABITAT |
| Owner: FLAGLER HABITAT FOR HUMANITY INC |
|
Address PO BOX BUNNELL, FL 32110 |
| Lot: 0250 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
FLAGLER HABITAT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 WEST MOODY BLVD BUNNELL, FL 32110 |
HABITAT | 386-931-2131 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
MICHAEL A PENAGOS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3321 GLENSHANE WAY ORMOND BEACH, FL 32174 |
CCC1330460 (Exp: 08/31/2026) | 386-569-9133 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/03/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| BLD - BUILDING FINAL | 07/01/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC [A] 107.4-MECHANICAL EQUIPMENT DOES NOT MATCH ENERGY CALCS ( Ah do not match model number ) #2-FBC [A]107.4 -NOT READY - WORK INCOMPLETE ( garage full of aquitment tools , still have personel working aroung interior of the house , paint ) #3- Electrical outlet plate have opening on sides , in a few outlets arounf the house | |||
| U -UTILITY RESIDENTIAL FINAL | 06/27/2025 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 06/25/2025 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 06/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/24/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/24/2025 | APPROVED | TPOLACEK |
| Note: UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 06/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ELECTRIC - EARLY POWER | 06/09/2025 | APPROVED | CVANSTRAHLEN |
| ROW- PRE-APRON (PRE-POUR) | 05/16/2025 | APPROVED | FSLADISH |
| Note: 5/16/25 PIPE ELEVATION GOOD. BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE CONCRETE IS 3000 PSI BUILDER RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| GRAVITY SEWER TEST | 05/15/2025 | APPROVED | MGIBSON |
| SEWER TIE IN | 05/15/2025 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 05/08/2025 | APPROVED | CBOWERMASTER |
| INSULATION | 05/01/2025 | APPROVED | CVANSTRAHLEN |
| Note: | |||
| ALL ROUGH | 04/28/2025 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection : #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE #2- MIssing FL Approval sheet for windows and door | |||
| WALL SHEATHING | 04/25/2025 | APPROVED | CVANSTRAHLEN |
| ROOF VALLEY & METAL | 04/24/2025 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/15/2025 | APPROVED | CVANSTRAHLEN |
| LATH/BRICK/ WATER BARRIER | 03/25/2025 | APPROVED | CVANSTRAHLEN |
| Note: nealing inspection for window was made . all windows been proper nealing ans seal , Approved to install sidding | |||
| WALL SHEATHING | 03/13/2025 | PARTIALLY APPROVED | CVANSTRAHLEN |
| Note: *** NOTES ADDED BY CVANSTRAHLEN 3/13/2025 8:56:45 AM *** PLease moved porta-join out of swell Need trusses install | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/12/2025 | APPROVED | MGIBSON |
| Note: 2/14/2025 - PREVIOUS INSPECTION NOTES WATER SERVICE NOT RAN YET, FINISH LEFT SIDE SILT FENCE ON LEFT SIDE OF PROPERTY BY SLAB INSPECTION | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/05/2025 | APPROVED | RRICKS |
| MONOLITHIC SLAB | 02/18/2025 | APPROVED | CVANSTRAHLEN |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/14/2025 | PARTIALLY APPROVED | MGIBSON |
| Note: WATER SERVICE NOT RAN YET, FINISH LEFT SIDE SILT FENCE ON LEFT SIDE OF PROPERTY BY SLAB INSPECTION | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 02/13/2025 | APPROVED | PKNAPIK |
| ELECTRIC TEMP POLE | 02/07/2025 | APPROVED | CVANSTRAHLEN |
| WATER METER INSTALLATION REQUEST | 01/23/2025 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/01/2025 | 07/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/05/2025 | 03/05/2025 |
| Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/05/2025 | 03/05/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/14/2025 | 02/14/2025 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/06/2025 | 02/06/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/05/2025 | 02/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/05/2025 | 02/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/05/2025 | 02/06/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/05/2025 | 02/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/05/2025 | 02/06/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/05/2025 | 02/05/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Revised plans are for garage right but Elevation page for garage left | |||
| BADMIN | INFORMATION | 02/04/2025 | 02/04/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME TO SITE PLAN.PDF, A.5.PDF, E1.PDF, ... | |||
| BADMIN | INFORMATION | 02/04/2025 | 02/04/2025 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME TO REVISED SITE PLAN.PDF 2. SELECT 'REVISED SITE PLAN' FROM DROP DOWN MENU | |||
| ELEC | COMPLETE | 01/08/2025 | 01/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/08/2025 | 01/08/2025 |
| Note: Held By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM 1. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| BLD | COMPLETE | 01/07/2025 | 01/08/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/02/2025 | 01/08/2025 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/02/2025 | 01/03/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/02/2025 | 01/02/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM No zoning changes | |||
| SWALE | COMPLETE | 12/04/2024 | 12/17/2024 |
| Note: Released By: LEVI SALYERDS - - LSALYERDS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 12/02/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/02/2024 | 12/09/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) 2. Provide florida product approval number for underlayment on roofing worksheet 3. Florida product approval number 17676.5 is not valid | |||
| CUSVC | COMPLETE | 12/02/2024 | 12/03/2024 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 12/02/2024 | 12/09/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical load calcs. | |||
| ENGIN1 | COMPLETE | 12/02/2024 | 12/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 12/02/2024 | 12/06/2024 |
| LOCATE | COMPLETE | 12/02/2024 | 12/05/2024 |
| Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/02/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/02/2024 | 12/16/2024 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Revise grading to have right side match Lot 26 with a B Drainage, left side may remain an A Drainage to match Lot 24. Please review left side to see if a common swale may be achievable. | |||
| ZON | COMPLETE | 12/02/2024 | 12/02/2024 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/03/2025 |
| CONNECTION FEES | ¤1,187.26 | 01/14/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 01/14/2025 |
| IMPACT FEE FIRE | ¤434.51 | 01/14/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/14/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/14/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 01/14/2025 |
| IMPACT FEE TRANSPORTATION | ¤1,916.00 | 01/14/2025 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/14/2025 |
| SURCHARGE FS 533.721 | ¤8.91 | 01/14/2025 |
| SURCHARGE - FS 468.631 | ¤13.37 | 01/14/2025 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/14/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/14/2025 |
| SW ENG PRE APRON | ¤30.00 | 01/14/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/14/2025 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/14/2025 |
| SEWER CREDIT | (¤1,466.00) | 01/14/2025 |
| SEWER INSPECTION | ¤25.00 | 01/14/2025 |
| SEWER CAPITAL FACILITY | ¤6,120.52 | 01/14/2025 |
| WATER CAPITAL FACILITY FEE | ¤4,351.14 | 01/14/2025 |
| SITE PLAN 30 | ¤30.00 | 01/14/2025 |
| WATER- TURN ON | ¤25.00 | 01/14/2025 |
| ADJUSTMENT 10% | (¤99.02) | 01/14/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/14/2025 |
| INSPECTION - RESIDENTIAL | ¤748.00 | 01/14/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤212.16 | 01/14/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,327.86 |