I want to search for...

Permit #2024120037

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00110-0190
CONDITIONED SPACE: 1800 sqft
GARAGE: 410 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2246 sqft
Block: 00110
Subdivision: -
Job Phone: 689-250-2429
Location Address: 13 ROUND TABLE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/17/2024
NOC: RECORDED
Applicant name: RYAN M COURECH
Owner: A AND R-MERIDIAN REAL ESTATE

Address

688 N ORLANDO AVENUE

MAITLAND , FL 32751

Address

SUITE 207

MAITLAND , FL 32751

Lot: 0190
Contracted Stated Job Value: ¤208,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN
Original Permit #: 2024010999

Contractor

MCH CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

668 N ORLANDO AVE, STE 207

MAITLAND, FL 32751

CBC1262898 (Exp: 08/31/2026) 407-602-8257

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DUSTIN ARCHER
Status Location Address State License Number Phone
ACTIVE

2785 WRIGHTS ROAD SUITE 1133

OVIEDO, FL 32765

CMC1251099 (Exp: 08/31/2026) 407-391-1145
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 09/11/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 09/11/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/10/2025 APPROVED RRICKS
ROW FIELD SURVEY /GRADING CERTIFICATION 09/10/2025 APPROVED RRICKS
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
BLD - BUILDING FINAL 09/05/2025 Approval - Private Provider PPROVIDER
ROW- PRE-APRON (PRE-POUR) 08/19/2025 APPROVED - AS NOTED TPOLACEK
Note: 08/19/25 TPOLACEK**** CORRECTIONS MADE, PLEASE BACKFILL AGAINST FORM BOARDS TO PREVENT OVERPOUR AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/13/2025 - PREVIOUS INSPECTION NOTES 08/13/25 TPOLACEK*** CULVERT IS BACKPITCHED AGAINST FLOW, CULVERT IS SET AT 8' HOWEVER FORM BOARD ALONG ROAD EDGE IS NOT SET CORRECTLY TO 8', FOOTERS ARE WASHED IN AND NEED TO BE REESTABLISHED, THERE IS NOT 6" THROUGHOUT THE ROW POUR AREA. 9 Thickness of Concrete in the ROW Sec.900.04A Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. SWALE PLAN 2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow
ROW- PRE-APRON (PRE-POUR) 08/15/2025 CANCELLED BY APPLICANT WEB
Note: 8/13/2025 - PREVIOUS INSPECTION NOTES 08/13/25 TPOLACEK*** CULVERT IS BACKPITCHED AGAINST FLOW, CULVERT IS SET AT 8' HOWEVER FORM BOARD ALONG ROAD EDGE IS NOT SET CORRECTLY TO 8', FOOTERS ARE WASHED IN AND NEED TO BE REESTABLISHED, THERE IS NOT 6" THROUGHOUT THE ROW POUR AREA. 9 Thickness of Concrete in the ROW Sec.900.04A Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. SWALE PLAN 2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow
ROW- PRE-APRON (PRE-POUR) 08/13/2025 Disapproved -FEE REQUIRED TPOLACEK
Note: 08/13/25 TPOLACEK*** CULVERT IS BACKPITCHED AGAINST FLOW, CULVERT IS SET AT 8' HOWEVER FORM BOARD ALONG ROAD EDGE IS NOT SET CORRECTLY TO 8', FOOTERS ARE WASHED IN AND NEED TO BE REESTABLISHED, THERE IS NOT 6" THROUGHOUT THE ROW POUR AREA. 9 Thickness of Concrete in the ROW Sec.900.04A Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. SWALE PLAN 2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 1 The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 Sec.300.01 B3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow, nor shall it be sloped more than 0.10 of a foot in the direction of the drainage flow
ROW- PRE-APRON (PRE-POUR) 07/29/2025 CANCELLED BY APPLICANT WEB
U - SEWER TIE IN 07/15/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U-CROSS CONNECTION 07/15/2025 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cc
GRAVITY SEWER TEST 07/15/2025 Approval - Private Provider PPROVIDER
INSULATION 07/02/2025 Approval - Private Provider PPROVIDER
ELECTRIC - EARLY POWER 06/27/2025 Approval - Private Provider PPROVIDER
ROW - DRAINAGE 06/23/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2025 - PREVIOUS INSPECTION NOTES 06/16/25 TPOLACEK*** BUILDER MUST REESTABLISH TEMPORARAY PIPE AND OPEN SWALE. NEXT INSPECTION MONDAY 06-23
ALL ROUGH 06/20/2025 Approval - Private Provider PPROVIDER
WALL SHEATHING 06/20/2025 Approval - Private Provider PPROVIDER
ROW - DRAINAGE 06/16/2025 Disapproved - NO FEE TPOLACEK
Note: 06/16/25 TPOLACEK*** BUILDER MUST REESTABLISH TEMPORARAY PIPE AND OPEN SWALE. NEXT INSPECTION MONDAY 06-23
LATH/BRICK/ WATER BARRIER 06/11/2025 Approval - Private Provider PPROVIDER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/30/2025 Approval - Private Provider PPROVIDER
ROOF VALLEY & METAL 05/30/2025 Approval - Private Provider PPROVIDER
TIE BEAM / LINTEL 04/28/2025 Approval - Private Provider PPROVIDER
MONOLITHIC SLAB 04/28/2025 Approval - Private Provider PPROVIDER
FOUND SURVEY APPROVED (OFFICE) 04/11/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 02/18/2025 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 02/18/2025 Approval - Private Provider PPROVIDER
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 01/14/2025 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 01/10/2025 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 08/06/2025 08/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/10/2025 04/11/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/10/2025 04/10/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/09/2025 01/14/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/08/2025 01/09/2025
Note: Released By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM
MECH COMPLETE 12/31/2024 01/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 12/03/2024 12/17/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/02/2024 12/02/2024
Note: Released By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM
MECH COMPLETE 12/02/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 12/02/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 12/02/2024 12/03/2024
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/02/2024 12/03/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/02/2024 12/05/2024
Note: Released By: TONI CHURCHILL - - TCHURCHILL@PALMCOASTGOV.COM
SW1 INFORMATION 12/02/2024 12/16/2024
Note: Marked INFORMATION By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Site plan is approved, however the construction type is needed; either concrete block or wood frame.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/11/2025
PLAN REVIEW - REVISION ¤32.50 09/11/2025
SW ENG REINSPECTION 30 ¤30.00 09/11/2025
SW ENG - INSPECTION 20 ¤20.00 09/11/2025
SW ENG - INSPECTION 20 ¤20.00 09/11/2025
IMPACT FEE TRANSPORTATION ¤1,862.00 12/17/2024
WATER -IRRIGATION INSPECTION ¤25.00 12/17/2024
SURCHARGE FS 533.721 ¤3.27 12/17/2024
SURCHARGE - FS 468.631 ¤4.90 12/17/2024
SW ENG - FOUNDATION SURVEY ¤20.00 12/17/2024
WATER- TURN ON ¤25.00 12/17/2024
ADJUSTMENT 10% (¤11.32) 12/17/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/17/2024
ADMINISTRATIVE - RESID PP ¤225.00 12/17/2024
PLAN REVIEW - APPROVED MASTER ¤83.20 12/17/2024
CONNECTION FEES ¤1,187.26 12/17/2024
CONTRACTOR CHANGE ¤20.00 12/17/2024
FC IMPACT FEE EMS ¤62.00 12/17/2024
IMPACT FEE FIRE ¤434.51 12/17/2024
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 12/17/2024
FC IMPACT FEE LIBRARY ¤268.00 12/17/2024
IMPACT FEE PARKS ¤1,828.01 12/17/2024
IMPACT FEE SCHOOL ¤5,450.00 12/17/2024
SW ENG INSPECTION 80 ¤80.00 12/17/2024
SW ENG PRE APRON ¤30.00 12/17/2024
SW ENG - REVIEW 20 ¤20.00 12/17/2024
SW ENG RES REVIEW 200 ¤200.00 12/17/2024
SEWER CREDIT (¤1,147.00) 12/17/2024
SEWER INSPECTION ¤25.00 12/17/2024
SEWER CAPITAL FACILITY ¤6,120.52 12/17/2024
WATER CAPITAL FACILITY FEE ¤4,351.14 12/17/2024
SITE PLAN 30 ¤30.00 12/17/2024
Fees Total Due: ¤0.00 Total Paid: ¤21,579.49