I want to search for...

Permit #2024120171

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00200-0200
Total Square Footage: 32 sqft
Block: 00200
Subdivision: 7028 -
Job Phone: 386-546-4942
Location Address: 5 POTTERVILLE LN
Type: RF - REROOF
Issue Date: 12/05/2024
NOC: RECORDED
Applicant name: MORGAN STRICKLAND
Owner: APPRAISING ST JOHNS COUNTY LLC

Address

704 ALDEN WAY

SAINT AUGUSTINE, FL 32086

Lot: 0200
Contracted Stated Job Value: ¤15,575.00
Job Description: Tear off existing roof and install new metal roof on house
Type: CN

Contractor

GEORGIA METALS ROOFING, LLC
Status Location Address State License Number Phone
ACTIVE

153 US HWY 17 SOUTH

EAST PALATKA, FL 32131

CCC1326728 (Exp: 08/31/2026) 386-328-5509

Inspection History

Type Request Date Result Inspector
ROOF SHEATHING 02/11/2025 APPROVED - AS NOTED HCAMACHO
Note: Engineer's letter has been accepted and approved by building department.
ROOF IN PROGRESS- MIDROOF 02/11/2025 APPROVED - AS NOTED HCAMACHO
Note: Engineer's letter has been accepted and approved by building department.
ROOF FINAL 02/11/2025 FINAL APPROVED HCAMACHO
Note: Engineer's letter has been accepted and approved by building department. Installed per letter.
ROOF IN PROGRESS- MIDROOF 01/07/2025 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2025 4:11:03 PM *** 1/7/25: Roof is completely covered prior to approved Mid-roof inspection. 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Engineering letter has not been approved by building officials. Please schedule inspection when letter has been approved. No work is to be completed until approval and inspection 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/24: First stop at 10:45 not ready for Mid-roof inspection yet. (Checked sheathing - not approved due to existing OSB - See roof sheathing inspection). 2nd stop at 12:30. Not ready. Missing field nails at 12" OC as required. Valley areas are not double layered underlayment. 905.1.1.1(4)
ROOF AFFIDAVIT 01/07/2025 APPROVED CGONCALVES
ROOF SHEATHING 01/07/2025 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 1/7/2025 4:12:10 PM *** 1/7/25: Engineer's letter is only accepted must be approved prior to inspection approval. 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Engineering letter has not been approved by building officials. Please schedule inspection when letter has been approved. No work is to be completed until approval and inspection 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/24: Product approval code document on site shows FPA# 28363.2 which requires 15/32" min. 4-ply CDX plywood or approved equivelant by others. Engineer's letter confirms the 15/32" min 4-ply CDX or other rated/approved wood structural roof deck constructions which meet or exceed the fastener holding strength as tested. However, the existing roof sheathing is 15/32" - OSB. Correction or revision (which includes Engineer's stamped letter stating approval of OSB) will be required.
ROOF SHEATHING 12/31/2024 Disapproved - NO FEE MCONTRYMAN
Note: 12/31/24 1. Engineering letter has not been approved by building officials. Please schedule inspection when letter has been approved. No work is to be completed until approval and inspection 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/24: Product approval code document on site shows FPA# 28363.2 which requires 15/32" min. 4-ply CDX plywood or approved equivelant by others. Engineer's letter confirms the 15/32" min 4-ply CDX or other rated/approved wood structural roof deck constructions which meet or exceed the fastener holding strength as tested. However, the existing roof sheathing is 15/32" - OSB. Correction or revision (which includes Engineer's stamped letter stating approval of OSB) will be required.
ROOF IN PROGRESS- MIDROOF 12/31/2024 Disapproved - NO FEE MCONTRYMAN
Note: 12/31/24 1. Engineering letter has not been approved by building officials. Please schedule inspection when letter has been approved. No work is to be completed until approval and inspection 12/30/2024 - PREVIOUS INSPECTION NOTES 12/30/24: First stop at 10:45 not ready for Mid-roof inspection yet. (Checked sheathing - not approved due to existing OSB - See roof sheathing inspection). 2nd stop at 12:30. Not ready. Missing field nails at 12" OC as required. Valley areas are not double layered underlayment. 905.1.1.1(4)
ROOF IN PROGRESS- MIDROOF 12/30/2024 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 12/30/2024 12:51:19 PM *** 12/30/24: First stop at 10:45 not ready for Mid-roof inspection yet. (Checked sheathing - not approved due to existing OSB - See roof sheathing inspection). 2nd stop at 12:30. Not ready. Missing field nails at 12" OC as required. Valley areas are not double layered underlayment. 905.1.1.1(4)
ROOF SHEATHING 12/30/2024 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 12/30/2024 10:55:25 AM *** 12/30/24: Product approval code document on site shows FPA# 28363.2 which requires 15/32" min. 4-ply CDX plywood or approved equivelant by others. Engineer's letter confirms the 15/32" min 4-ply CDX or other rated/approved wood structural roof deck constructions which meet or exceed the fastener holding strength as tested. However, the existing roof sheathing is 15/32" - OSB. Correction or revision (which includes Engineer's stamped letter stating approval of OSB) will be required.

Review History

Department Status Date In Date Out
BLD COMPLETE 01/29/2025 01/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 01/21/2025 01/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 01/06/2025 01/06/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Letter needs to be digitally signed and sealed.
BLD COMPLETE 12/04/2024 12/05/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 01/14/2025
REINSPECTION RESIDENTIAL ¤40.00 12/30/2024
SURCHARGE FS 533.721 ¤2.00 12/05/2024
SURCHARGE - FS 468.631 ¤2.00 12/05/2024
ADJUSTMENT 10% (¤9.00) 12/05/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/05/2024
INSPECTION - RESIDENTIAL ¤60.00 12/05/2024
Fees Total Due: ¤0.00 Total Paid: ¤165.00