I want to search for...
Permit #2024120478
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7001-00130-0190 |
| Block: 00130 |
| Subdivision: 7001 - |
| Job Phone: 386-252-1878 |
| Location Address: 5 FIRTREE LN |
| Type: WH - WATER HEATER |
| Issue Date: 12/11/2024 |
| NOC: Unknown |
| Applicant name: BRENT JAMES STURGELL |
| Owner: SCHUTZ LESLIE ANN |
|
Address 5 FIRTREE LANE PALM COAST, FL 32137 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤1,450.00 |
| Job Description: HOT WATER HEATER CHANGE OUT |
| Type: CN |
Contractor
KOONTZ HEATING & AIR CONDITIONING
| Status | Location Address | State License Number | Phone |
| ACTIVE |
651 CARSWELL AVE HOLLY HILL , FL 32117 |
CFC1433230 (Exp: 08/31/2026) | 386-252-1878 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 02/24/2025 | FINAL APPROVED | MGIBSON |
| Note: 2/19/2025 - PREVIOUS INSPECTION NOTES 1/24/2025 - PREVIOUS INSPECTION NOTES 1/7/2025 - PREVIOUS INSPECTION NOTES Copper pipes need bonding jumper from cold to hot. E3608.1.1.PVC PIPE NOT APPROVED TO TIE INTO T&P VALVE CAN DROP TO 6'' ABOVE FINISHED GRADE AT FLOOR LEVEL ''PVC IS NOT RATED FOR T&P VALVE!!!!'' SHALL BE ''CPVC'' THIS WAS A VIRTUAL INSPECTION | |||
| PLUMBING FINAL | 02/19/2025 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: 1/24/2025 - PREVIOUS INSPECTION NOTES 1/7/2025 - PREVIOUS INSPECTION NOTES Copper pipes need bonding jumper from cold to hot. E3608.1.1.PVC PIPE NOT APPROVED TO TIE INTO T&P VALVE CAN DROP TO 6'' ABOVE FINISHED GRADE AT FLOOR LEVEL ''PVC IS NOT RATED FOR T&P VALVE!!!!'' SHALL BE ''CPVC'' | |||
| PLUMBING FINAL | 01/24/2025 | Disapproved - NO FEE | MGIBSON |
| Note: 1/7/2025 - PREVIOUS INSPECTION NOTES Copper pipes need bonding jumper from cold to hot. E3608.1.1.PVC PIPE NOT APPROVED TO TIE INTO T&P VALVE CAN DROP TO 6'' ABOVE FINISHED GRADE AT FLOOR LEVEL | |||
| PLUMBING FINAL | 01/07/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: Copper pipes need bonding jumper from cold to hot. E3608.1.1 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/19/2025 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/11/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/11/2024 |
| ADJUSTMENT 10% | (¤9.00) | 12/11/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/11/2024 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 12/11/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤125.00 |