I want to search for...

Permit #2024120520

Permit Details

Status: COED

COMMERCIAL SQUARE FOOTAGE: 2883 sqft
Total Square Footage: 3406 sqft
Block: 000A0
Subdivision: 2342 - POINTE GRAND AT TOWN CENTER
Job Phone: 312-925-1236
Location Address: 746 TOWN CENTER BLVD
Type: BC - BUILDING COMMERCIAL
Issue Date: 10/21/2025
NOC: RECORDED
Applicant name: FREDERICK WILLIAM MAHONEY
Owner: HP-232090 PALM COAST QOZB LLC

Address

101 S NEW YORK AVENUE

WINTER PARK, FL 32789

Address

SUITE 211

WINTER PARK, FL 32789

Lot: 0013
Contracted Stated Job Value: ¤415,000.00
Job Description: Clubhouse
Type: CN

Contractor

HILLPOINTE CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

101 S. NEW YORK AVE, SUITE 211

WINTER PARK, FL 32789

CGC1531505 (Exp: 08/31/2026) 407-752-9004

Sub Contractors

RENE NOUSSIMEE-TOUKO
Status Location Address State License Number Phone
ACTIVE

8830 MACON HWY BLDG 300

WINTER PARK, FL 32789

CAC1821831 (Exp: 08/31/2026) 312-925-1236
RENE NOUSSIMEE-TOUKO
Status Location Address State License Number Phone
ACTIVE

8830 MACON HWY BLDG 300

WINTER PARK, FL 32789

CFC1430843 (Exp: 08/31/2026) 352-363-9162
ERICH MICHAEL SMIT
Status Location Address Mailing Address State License Number Phone
ACTIVE

8830 MACON HWY

WINTER PARK, FL 32789

BLD 300

ATHENS, GA 30606

EC13013930 (Exp: 08/31/2026) 352-363-9162
FREDERICK WILLIAM MAHONEY
Status Location Address State License Number Phone
ACTIVE

101 S. NEW YORK AVE, SUITE 211

WINTER PARK, FL 32789

CGC1531505 (Exp: 08/31/2026) 407-752-9004

Inspection History

Type Request Date Result Inspector
FIRE FINAL 05/26/2026 APPROVED RMARTIN
Note: New inspection due to canceled inspection 5/8/2026 - PREVIOUS INSPECTION NOTES Need to close out all other inspections
ELECTRIC FINAL 05/22/2026 APPROVED RMARTIN
Note: 5/6/2026 - PREVIOUS INSPECTION NOTES Need to have approved revision on all electrical added in the building.
FIRE FINAL 05/20/2026 CANCELLED BY APPLICANT WEB
Note: 5/8/2026 - PREVIOUS INSPECTION NOTES Need to close out all other inspections
U - UTILITY COMMERCIAL FINAL 05/20/2026 FINAL APPROVED BHAINES
BUILDING FINAL 05/19/2026 APPROVED HCAMACHO
Note: 5/8/2026 - PREVIOUS INSPECTION NOTES 1. Doors Exiting the club house on the right side of the building do not match plans A101 and door Schedule A300. The doors in question are A113a and A113.
FIRE FINAL 05/08/2026 CANCELLED BY APPLICANT JMUNSON
Note: Need to close out all other inspections
BUILDING FINAL 05/08/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Doors Exiting the club house on the right side of the building do not match plans A101 and door Schedule A300. The doors in question are A113a and A113.
EXTERIOR ARCHITECTURAL FEATURES 05/08/2026 APPROVED RPICATAGI
HVAC FINAL 05/08/2026 APPROVED HCAMACHO
PLUMBING FINAL 05/06/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Need hammer arrestor on dishwasher. Will look at Building Final.
ELECTRIC FINAL 05/06/2026 Disapproved - NO FEE RMARTIN
Note: Need to have approved revision on all electrical added in the building.
GRAVITY SEWER 04/22/2026 APPROVED HCAMACHO
WATER SERVICE 04/22/2026 APPROVED HCAMACHO
ELECTRIC - EARLY POWER 04/15/2026 APPROVED RMARTIN
Note: Inspector Notes from Inspection 3190 Need to have approved revision by electric final on added outlets in club house, many through out. Ufer ground
HORIZONTAL ASSEMB DRYWALL 03/03/2026 APPROVED HCAMACHO
INSULATION 02/25/2026 APPROVED HCAMACHO
BLD - SEWER TIE IN 02/19/2026 APPROVED HCAMACHO
PLUMBING 2ND ROUGH 02/13/2026 APPROVED HCAMACHO
Note: 1/29/2026 - PREVIOUS INSPECTION NOTES Water supply for pool use in pool room calls for 1" and it was reduced to 3/4".
HVAC ROUGH 02/13/2026 APPROVED HCAMACHO
Note: 2/12/2026 - PREVIOUS INSPECTION NOTES 1. Seams on fresh air pipe need to be finished. *Volume Dampers will be installed on the Fresh air, supply and return difusers for balancing. Will check at Final.
HVAC ROUGH 02/12/2026 PARTIALLY APPROVED HCAMACHO
Note: 1. Seams on fresh air pipe need to be finished. *Volume Dampers will be installed on the Fresh air, supply and return difusers for balancing. Will check at Final.
ABOVE CEILING 02/12/2026 APPROVED RMARTIN
ELECTRIC 2ND ROUGH 01/29/2026 APPROVED - AS NOTED RMARTIN
Note: Need to have approved revision by electric final on added outlets in club house, many through out. Ufer ground
PLUMBING 2ND ROUGH 01/29/2026 PARTIALLY APPROVED HCAMACHO
Note: Water supply for pool use in pool room calls for 1" and it was reduced to 3/4".
LINTEL 01/29/2026 CANCELLED BY INSPECTOR HCAMACHO
Note: Inspection not needed do to building being frame
FRAMING 01/29/2026 APPROVED HCAMACHO
FOUNDATION SURVEY - OFFICE USE ONLY 01/28/2026 APPROVED DLEAP
EXTERIOR WALL SHEATHING / SHEARWALL 12/29/2025 APPROVED HCAMACHO
Note: 12/4/2025 - PREVIOUS INSPECTION NOTES Exterior wall sheathing all.
ROOF SHEATHING / BRACE / TIE DOWN 12/29/2025 APPROVED HCAMACHO
Note: 12/4/2025 - PREVIOUS INSPECTION NOTES Roof sheathing, and parapet walls sheathing.
LATH/BRICK/WATER BARRIER 12/17/2025 APPROVED KSANDOE
STOREFRONT 12/16/2025 APPROVED KSANDOE
Note: 12/15/2025 - PREVIOUS INSPECTION NOTES
STOREFRONT 12/15/2025 CANCELLED BY APPLICANT KSANDOE
ROOF IN PROGRESS 12/09/2025 APPROVED KSANDOE
ROOF IN PROGRESS 12/08/2025 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACE / TIE DOWN 12/04/2025 PARTIALLY APPROVED HCAMACHO
Note: Roof sheathing, and parapet walls sheathing.
EXTERIOR WALL SHEATHING / SHEARWALL 12/04/2025 PARTIALLY APPROVED HCAMACHO
Note: Exterior wall sheathing all.
EXTERIOR WALL SHEATHING / SHEARWALL 12/03/2025 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 11/05/2025 APPROVED KSANDOE
FOOTER 11/05/2025 APPROVED KSANDOE
ELECTRIC OTHER 11/05/2025 APPROVED - AS NOTED RMARTIN
Note: Ufer ground
ELECTRIC 1ST ROUGH 11/05/2025 APPROVED RMARTIN
PLUMBING 1ST ROUGH 11/04/2025 APPROVED MGIBSON
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/03/2025 APPROVED JMUNSON

Review History

Department Status Date In Date Out
ELEC COMPLETE 05/21/2026 05/22/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLENG COMPLETE 01/26/2026 01/28/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
PLUM COMPLETE 10/07/2025 10/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/07/2025 10/20/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
FI1 COMPLETE 03/14/2025 03/14/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 HOLD 03/07/2025 03/11/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 3. Please supply a Life Safety Plan and show location of required fire extinguisher per FFPC 1, 13.6.3.2.1.2.2 Fire extinguishers shall be located so that the maximum travel distances shall not exceed 75 ft. 4. 6.1.3.3 Visual Obstructions…. Fire extinguishers shall not be obstructed or obscured from view per NFPA 10, 6.1.3.3.1 5. There wasn't a life safety plan submitted.
ARCHR COMPLETE 03/07/2025 03/20/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD HOLD 03/07/2025 03/24/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. General 1. OK 2. OK 3. OK 4. OK All Architectural Plan Sheets 1. OK Cover Sheet 1. OK REPEAT COMMENT: 2. In Building Information section, provide total design occupant load for building including all areas such as rear porch. FBCB 1004.1. (NO POOL ENGINEERING PROVIDED, AND NO POOL PERMIT APPLIED FOR. PROVIDE OCCUPANT LOAD FOR ENTIRE FACILITY INCLUDING POOL DECK. NEEDS TO BE ON YOUR PLAN PAGES) Plan Sheet A-1 REPEAT COMMENT: 1. Confirm in a response letter the floor area of the building includes areas under roof projections for the front canopy and rea “lounging area poolside” covered porch. FBCB Section 503.1, 202 – definition of “area, building”. If area under roof projections was not included, revise and add it to the building area on the Cover Sheet.. (RESPONSE NOT ACCEPTED. SEE DEFINITION OF AREA OF A BUILDING. NEEDS TO BE ON YOUR PLAN PAGES) 2. OK 3. OK 4. Provide plumbing fixture calculations based on building occupancy, pool bathing load, pool deck occupants and occupants for any other outdoor use area this building will serve. For pool bathing load see FBCB 454.1.1.1. For pool deck occupants see 1004.1, 12004.3 Table 1004.5 (assembly without fixed seats 7 / net OLF). For other use areas, if any, use the appropriate OLF per Table 1004.5. (NO POOL ENGINEERING PROVIDED, AND NO POOL PERMIT APPLIED FOR. PROVIDE OCCUPANT LOAD FOR ENTIRE FACILITY INCLUDING POOL DECK, BATHER LOAD AND OUTSIDE AREAS. NEEDS TO BE ON YOUR PLAN PAGES) Plan Sheet A-2 1. OK 2. OK Plan Sheet A-5. 1. In Life Safety Chart show total building design occupant load. FBCB 1004.1. Include outside area such as rear Lounging Area Poolside / covered porch. If any part of the pool, pool deck or similar outdoor areas associated with the adjacent pool and / or other outdoor areas are intended to pass through the building as part of the means of egress for those areas, include, by separate line item, the total number of occupants expected in the building’s means of egress system. Rear door swing may need to be changed dependent on the number of occupants entering the building from the outdoor areas. Outdoor areas including pool and pool deck may be classified as an A3 occupancy dependent on occupant load and if it exceeds 50 occupants. Use 7 net square feet per occupant to determine number of occupants. FBCB 1004.7, Table 1004.5. Ensure building means of egress system is designed for additional outdoor area occupants. FBCB 1005 and other applicable portions of FBCB Chapter 10. (YOU HAVE INDICATED THAT THERE IS NO EGRESS INTO THE BUILDING. YOU STILL NEED TO PROVIDE CALCULATION OF OCCUPANT LOAD BASED ON B OCCUPANCY) Plan Sheet A-6 1. OK 2. OK All Structural Plan Sheets 1. OK 2. OK 3. OK Plan Sheet S1.0 1. OK 2. OK
PLUM HOLD 03/07/2025 03/20/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLEASE PROVIDE A RESPONSE LETTER FOR COMMENTS General 1. ok 2. ok 3. ok REPEAT COMMENT: 4. Provide roof drain specifications including manufacturer and model. Include published flow rates. FBCP 1105.1, 1105.2. REPEAT COMMENT: 5. Provide specifications for vertical conductors and leaders including materials, sizing, support, etc. FBCP 1106.1, 1106.2, 1106.3, 1106.4. 6. ok 7. ok 8. ok REPEAT COMMENT: 9. Provide complete design for secondary (emergency) roof drainage system. 1108.1, 1108.2, 1108.3. Provide complete specifications for all components. REPEAT COMMENT: 10. Provide complete design of the above through to eventual system outfall, whether it be above ground / overland or connected to below ground storm water system serving the site. FBCP Chapter 11. All Plumbing Plan Sheets 1. ok Plan Sheet P1.0 2. ok 3. ok 4. ok Plan Sheet P2.0 1. ok Plan Sheet P2.1 1. ok 2. ok
ARCHR HOLD 12/11/2024 12/27/2024
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide color schedule for all exteror surfaces. Refer to LDC Section 13.02
BLD HOLD 12/11/2024 12/27/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. General 1. Provide complete truss design package, signed and sealed by a Florida Professional Engineer. If not available, list truss package as a deferred submittal. FBCB 107.3.4.1. 2. Provide City of Palm Coast Product Approval Worksheet for all exterior components, including windows, doors, soffits, exterior cladding materials, etc. AHJ. 3. Provide roof framing plan sufficient to document location and material types for required attic draft stopping. FBCB 718.4, 718.4.1, 718.4.2, 718.4.3. Provide notes and details for fire blocking as well. FBCB 718.1, 718.2 through 718.2.7. 4. Revision number for TPO on roofing worksheet is from a previous code cycle. All Architectural Plan Sheets 1. Provide architectural business firm qualifier number in title block. FS 481.221, FAC 61G1-16.004 Cover Sheet 1. Plan sheet index does not match the number of architectural plan sheets uploaded to permit. Reconcile. AHJ. 2. In Building Information section, provide total design occupant load for building including all areas such as rear porch. FBCB 1004.1. Plan Sheet A-1 1. Confirm in a response letter the floor area of the building includes areas under roof projections for the front canopy and rea “lounging area poolside” covered porch. FBCB Section 503.1, 202 – definition of “area, building”. If area under roof projections was not included, revise and add it to the building area on the Cover Sheet. 2. Show sufficient area beyond rear Lounging Area Poolside to verify no-step accessible connection to future pool deck. Show location of accessible connection. FBCA 401.1, 402.1, 403.1 404.1. 3. Identify service sink and drinking fountain. FBCB Chapter 29, 2902.1 Tale 2902.1 No. 2. 4. Provide plumbing fixture calculations based on building occupancy, pool bathing load, pool deck occupants and occupants for any other outdoor use area this building will serve. For pool bathing load see FBCB 454.1.1.1. For pool deck occupants see 1004.1, 12004.3 Table 1004.5 (assembly without fixed seats 7 / net OLF). For other use areas, if any, use the appropriate OLF per Table 1004.5. Plan Sheet A-2 1. Provide clearance dimensions in front of water closet. Identify / label dimensions of all clearance boxes / circles. Label dimensions on these as well as 60 inch wheelchair turning space and clearance dimensions in front of lavatory. FBCA 604.8.1.1. 2. Provide accessible maneuverability details for coffee lounge sink based on direction of approach including knee and toe clearance if required and reach ranges to faucet etc. FBCA 606. Plan Sheet A-5. 1. In Life Safety Chart show total building design occupant load. FBCB 1004.1. Include outside area such as rear Lounging Area Poolside / covered porch. If any part of the pool, pool deck or similar outdoor areas associated with the adjacent pool and / or other outdoor areas are intended to pass through the building as part of the means of egress for those areas, include, by separate line item, the total number of occupants expected in the building’s means of egress system. Rear door swing may need to be changed dependent on the number of occupants entering the building from the outdoor areas. Outdoor areas including pool and pool deck may be classified as an A3 occupancy dependent on occupant load and if it exceeds 50 occupants. Use 7 net square feet per occupant to determine number of occupants. FBCB 1004.7, Table 1004.5. Ensure building means of egress system is designed for additional outdoor area occupants. FBCB 1005 and other applicable portions of FBCB Chapter 10. Plan Sheet A-6 1. Exterior wall sections shall provide complete design from surface of interior finish to surface of exterior cladding materials. It appears vapor retarder and water-resistive barrier details are missing. FBCB 107.2.4, 1405.3.1 through 1405.3.3, 1404.2. 2. How are roofs slopped to scuppers and in between scuppers? Over-framing? Tapered insulation? Please provide details indicating how water will be directed from spaces in between scuppers to the scuppers. If structural over-framing is to be used, structural plans shall be revised to reflect construction details. FBCB 1503.4, FBCP Chapter 11. All Structural Plan Sheets 1. All structural plan sheets shall be provided with a verifiable digital seal and signature. Seal provided is neither digital or verifiable. FS 471.025, FAC 61G15-23.004 2. All structural plan sheets shall include the project address: 746 Town Center Blvd. FAC 61G15-23.001. 3. Provide Plan Sheet Index for all submitted structural plan sheets. FS 481. Plan Sheet S1.0 1. In Structural Design Criteria SDC-2 B. provide roof rain load data. FBCB 1603.1.9. 2. In Structural Design Criteria SDC-2 B. provide design rain loads per Chapter 8 ASCE7-22 using Equation 16-19. The MEP engineer will need this data for storm drainage design. See Plumbing Plan Review Comments for further information.
DSD COMPLETE 12/11/2024 12/30/2024
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC COMPLETE 12/11/2024 12/30/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 HOLD 12/11/2024 12/18/2024
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter, provide clouded response changes on plan sheets and add page locations for each response. Please include FFPC 8th edition in the code analysis Please include FBC 8th edition in the code analysis If the building will have sprinklers and or alarm systems. Please provide the basis of design for the Sprinkler and Alarm systems as a governing document for the separate permit submittals required for fire sprinklers and alarms. 1. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 And place the following note on the cover sheet: Please call Fire Marshal, Randy Holmes at: 386-986-2303 for proper placement and verification of proper design and notification for the Fire Fighters Safety Building Marking System prior to placement. 2. Please place the following note on the plans. Water supply for fire protection must be made available and hydrants must be installed, completed, tested, and in service prior to prior to storage of materials and or commencing construction on any structure per NFPA 1 16.5.3.1.1 and NFPA 1, 16.5.3.1.3 3. Please supply a Life Safety Plan and show location of required fire extinguisher per FFPC 1, 13.6.3.2.1.2.2 Fire extinguishers shall be located so that the maximum travel distances shall not exceed 75 ft. 4. 6.1.3.3 Visual Obstructions…. Fire extinguishers shall not be obstructed or obscured from view per NFPA 10, 6.1.3.3.1
GAS CANCEL 12/11/2024 12/23/2024
MECH COMPLETE 12/11/2024 12/23/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 12/11/2024 12/27/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). General 1. Provide new plumbing plan sheet for roof drainage design in accordance with FBCP Chapter 11. 2. Coordinate with structural engineer to determine roof has been designed for the maximum possible depth of water that will pond, relative to the levels of roof deck and overflow weirs, scuppers or serviceable drains or combination thereof. FBCP 1101.7. 3. Provide material specifications for all materials used in design of roof storm drainage system. FBCP 1102.1, 1102.6, 1102.7. 4. Provide roof drain specifications including manufacturer and model. Include published flow rates. FBCP 1105.1, 1105.2. 5. Provide specifications for vertical conductors and leaders including materials, sizing, support, etc. FBCP 1106.1, 1106.2, 1106.3, 1106.4. 6. Provide rainfall rate conversion method. Show complete calculation for each roof / roof section / roof level. Show flows to each roof drain in g.p.m. and verify g.p.m. does not exceed published flow rates. FBCP 1106.2.1. 7. Provide size, location and inlet elevation for parapet wall scuppers. 8. Provide size of horizontal roof gutters, if any. FBCP 1106.6, Table 1106.6. 9. Provide complete design for secondary (emergency) roof drainage system. 1108.1, 1108.2, 1108.3. Provide complete specifications for all components. 10. Provide complete design of the above through to eventual system outfall, whether it be above ground / overland or connected to below ground storm water system serving the site. FBCP Chapter 11. All Plumbing Plan Sheets 1. Provide street address for project in Title Block. 746 Town Center Blvd. Plan Sheet P1.0 2. In piping schedule provide material specification for sanitary drain, waste and vent system. DWV is not a material type. Check the standard referenced (ASTM D1784) I do not see that standard in any of the tables. Provide schedule for both above ground and below ground pipe. Include design standards references for both. FBCP 702.1, 702.2 Table 702.1, Table 702.2. 3. In piping schedule provide material specifications for building sewer pipe. FBCB Section 702.3, Table 702.3. 4. In piping schedule provide material specification for both above ground water distribution piping and below ground. Only above ground has been provided. Include reference design standard. FBCP Plan Sheet P2.0 1. Is sanitary drain, waste and vent system is to be extended beyond building exterior walls to serve plumbing associated with future pool, show stub location and add notations as necessary. Plan Sheet P2.1 1. Since you are showing a piping diagram for pool equipment, also show piping to outdoor pool rinse shower and drinking fountain. 2. Identify that all hose-bibbs will be provided with back-flow protection. Identify type.
UD1 COMPLETE 12/11/2024 12/12/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤366.48) 10/21/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 10/21/2025
INSPECTION COMMERCIAL ¤2,905.00 10/21/2025
INSPECTION - FIRE COMMERCIAL ¤103.75 10/21/2025
PLAN REVIEW - COMMERCIAL ¤581.00 10/21/2025
IMPACT FEE FIRE ¤7,459.20 10/21/2025
SURCHARGE FS 533.721 ¤32.98 10/21/2025
SURCHARGE - FS 468.631 ¤49.47 10/21/2025
SITE PLAN 30 ¤30.00 10/21/2025
Fees Total Due: ¤0.00 Total Paid: ¤10,869.92