Permit Details

Status: COED

Parcel Id: 05-12-31-0650-000A0-0013
CONDITIONED SPACE: 27633 sqft
Total Square Footage: 27633 sqft
Block: 000A0
Subdivision: 2342 - POINTE GRAND AT TOWN CENTER
Job Phone: 312-925-1236
Location Address: 746 TOWN CENTER BLVD
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 08/12/2025
NOC: RECORDED
Applicant name: FREDERICK WILLIAM MAHONEY
Owner: HP-232090 PALM COAST QOZB LLC

Address

101 S NEW YORK AVENUE

WINTER PARK, FL 32789

Address

SUITE 211

WINTER PARK, FL 32789

Lot: 0013
Contracted Stated Job Value: ¤2,317,728.00
Job Description: Building 1000 - 24 unit Apartment
Type: CN

Contractor

HILLPOINTE CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

101 S. NEW YORK AVE, SUITE 211

WINTER PARK, FL 32789

CGC1531505 (Exp: 08/31/2026) 407-752-9004

Sub Contractors

RENE NOUSSIMEE-TOUKO
Status Location Address State License Number Phone
ACTIVE

8830 MACON HWY BLDG 300

WINTER PARK, FL 32789

CAC1821831 (Exp: 08/31/2026) 312-925-1236
RENE NOUSSIMEE-TOUKO
Status Location Address State License Number Phone
ACTIVE

8830 MACON HWY BLDG 300

WINTER PARK, FL 32789

CFC1430843 (Exp: 08/31/2026) 352-363-9162
ERICH MICHAEL SMIT
Status Location Address Mailing Address State License Number Phone
ACTIVE

8830 MACON HWY

WINTER PARK, FL 32789

BLD 300

ATHENS, GA 30606

EC13013930 (Exp: 08/31/2026) 352-363-9162
FREDERICK WILLIAM MAHONEY
Status Location Address State License Number Phone
ACTIVE

101 S. NEW YORK AVE, SUITE 211

WINTER PARK, FL 32789

CGC1531505 (Exp: 08/31/2026) 407-752-9004

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 05/21/2026 FINAL APPROVED BWRIGHT
U-CROSS CONNECTION 05/20/2026 APPROVED - AS NOTED BHAINES
Note: No CC, IRR with reclaim
U -UTILITY RESIDENTIAL FINAL 05/20/2026 FINAL APPROVED BWRIGHT
FIRE FINAL 05/20/2026 APPROVED RMARTIN
DEMOLITION 05/20/2026 CANCELLED BY INSPECTOR KSANDOE
PLUMBING FINAL 05/14/2026 APPROVED HCAMACHO
BUILDING FINAL 05/14/2026 APPROVED HCAMACHO
EXTERIOR ARCHITECTURAL FEATURES 05/12/2026 APPROVED RPICATAGI
HVAC FINAL 05/12/2026 APPROVED HCAMACHO
ELECTRIC FINAL 05/12/2026 APPROVED RMARTIN
FIREWALL FINAL 05/08/2026 APPROVED HCAMACHO
WATER METER INSTALLATION REQUEST 05/08/2026 APPROVED ISANDERSON
Note: Private
HORIZONTAL ASSEMB FINAL 05/08/2026 APPROVED HCAMACHO
ELECTRIC - EARLY POWER 04/21/2026 APPROVED RMARTIN
ELECTRIC 2ND ROUGH 04/02/2026 APPROVED RMARTIN
Note: 1/21/2026 - PREVIOUS INSPECTION NOTES 1. All wiring in panels must be properly phased. (check all units) ***Partial approved,call back in once repairs are made***
FIREWALL DRYWALL NAILING 02/20/2026 APPROVED HCAMACHO
Note: 12/1/2025 - PREVIOUS INSPECTION NOTES
HORIZONTAL ASSEMB DRYWALL 02/20/2026 APPROVED HCAMACHO
U - SEWER TIE IN 02/18/2026 APPROVED HCAMACHO
BLD - SEWER TIE IN 02/18/2026 APPROVED HCAMACHO
LATH/BRICK/WATER BARRIER 02/05/2026 APPROVED HCAMACHO
Note: 12/11/2025 - PREVIOUS INSPECTION NOTES Flashing in the Breeze ways 10/20/2025 - PREVIOUS INSPECTION NOTES Exterior Wall Sheathing. 10/17/2025 - PREVIOUS INSPECTION NOTES Several areas were not finished taping.- Corners of the breeze ways, and several areas on the balconies. *Call back for all the exterior wall sheathing*
HORIZONTAL ASSEMB FRAMING 02/04/2026 APPROVED HCAMACHO
INSULATION 02/04/2026 APPROVED HCAMACHO
HORIZONTAL ASSEMB PENETRATIONS 01/30/2026 APPROVED HCAMACHO
Note: 1/23/2026 - PREVIOUS INSPECTION NOTES Looke at the plumbing and Electrical penetrations. They were working on the HVAC.
FIREWALL PENETRATIONS 01/30/2026 APPROVED HCAMACHO
Note: 1/23/2026 - PREVIOUS INSPECTION NOTES Looke at the plumbing and Electrical penetrations. They were working on the HVAC.
HVAC ROUGH 01/30/2026 APPROVED HCAMACHO
Note: 1/27/2026 - PREVIOUS INSPECTION NOTES Fresh air joints
HVAC ROUGH 01/27/2026 PARTIALLY APPROVED HCAMACHO
Note: Fresh air joints
FIREWALL PENETRATIONS 01/23/2026 PARTIALLY APPROVED HCAMACHO
Note: Looke at the plumbing and Electrical penetrations. They were working on the HVAC.
LINTEL 01/23/2026 CANCELLED BY INSPECTOR HCAMACHO
Note: Not required the building is all Wood Frame Construction.
HORIZONTAL ASSEMB PENETRATIONS 01/23/2026 PARTIALLY APPROVED HCAMACHO
Note: Looke at the plumbing and Electrical penetrations. They were working on the HVAC.
WINDOW NAILING 01/21/2026 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 3460 Fire suppression room only
FRAMING 01/21/2026 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 3460 Fire suppression room only
FIREWALL FRAMING 01/21/2026 APPROVED HCAMACHO
Note: Inspector Notes from Inspection 3460 Fire suppression room only
ELECTRIC 2ND ROUGH 01/21/2026 PARTIALLY APPROVED MKRASKI
Note: 1. All wiring in panels must be properly phased. (check all units) ***Partial approved,call back in once repairs are made***
EXTERIOR WALL SHEATHING / SHEARWALL 01/20/2026 APPROVED - AS NOTED HCAMACHO
Note: Fire suppression room only
ROOF SHEATHING / BRACE / TIE DOWN 01/20/2026 APPROVED - AS NOTED HCAMACHO
Note: Fire suppression room only
PLUMBING 2ND ROUGH 01/12/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 1/12/2026 1:26:13 PM *** Inspector Notes from Inspection 3070 8/13/2025 - PREVIOUS INSPECTION NOTES ALL 3'' ST. 90'S NEED TO BE CHANGED . REFER TO P-706.3 TABLE WENT BACK @ 2: 41
MONOLITHIC SLAB 12/23/2025 APPROVED HCAMACHO
LATH/BRICK/WATER BARRIER 12/11/2025 PARTIALLY APPROVED HCAMACHO
Note: Flashing in the Breeze ways 10/20/2025 - PREVIOUS INSPECTION NOTES Exterior Wall Sheathing. 10/17/2025 - PREVIOUS INSPECTION NOTES Several areas were not finished taping.- Corners of the breeze ways, and several areas on the balconies. *Call back for all the exterior wall sheathing*
WINDOW NAILING 12/11/2025 PARTIALLY APPROVED HCAMACHO
Note: Missing ADA doors to balconies. 10/22/2025 - PREVIOUS INSPECTION NOTES Windows Only
FIREWALL DRYWALL NAILING 12/01/2025 PARTIALLY APPROVED KSANDOE
ROOF SHEATHING / BRACE / TIE DOWN 11/19/2025 APPROVED HCAMACHO
Note: 10/10/2025 - PREVIOUS INSPECTION NOTES Roof sheathing
EXTERIOR WALL SHEATHING / SHEARWALL 11/19/2025 APPROVED HCAMACHO
Note: 10/10/2025 - PREVIOUS INSPECTION NOTES Wall Sheathing
WINDOW NAILING 10/22/2025 PARTIALLY APPROVED HCAMACHO
Note: Windows Only
LATH/BRICK/WATER BARRIER 10/20/2025 PARTIALLY APPROVED HCAMACHO
Note: Exterior Wall Sheathing. 10/17/2025 - PREVIOUS INSPECTION NOTES Several areas were not finished taping.- Corners of the breeze ways, and several areas on the balconies. *Call back for all the exterior wall sheathing*
LATH/BRICK/WATER BARRIER 10/17/2025 PARTIALLY APPROVED HCAMACHO
Note: Several areas were not finished taping.- Corners of the breeze ways, and several areas on the balconies. *Call back for all the exterior wall sheathing*
ROOF VALLEY & METAL 10/17/2025 APPROVED HCAMACHO
ROOF SHEATHING / BRACE / TIE DOWN 10/10/2025 PARTIALLY APPROVED HCAMACHO
Note: Roof sheathing
EXTERIOR WALL SHEATHING / SHEARWALL 10/10/2025 PARTIALLY APPROVED HCAMACHO
Note: Wall Sheathing
FOUNDATION SURVEY - OFFICE USE ONLY 10/09/2025 APPROVED DLEAP
ELECTRIC OTHER 08/20/2025 APPROVED - AS NOTED RMARTIN
Note: This is for the ufer ground Island power
MONOLITHIC SLAB 08/20/2025 APPROVED KSANDOE
PLUMBING 1ST ROUGH 08/14/2025 APPROVED - AS NOTED MGIBSON
Note: 8/13/2025 - PREVIOUS INSPECTION NOTES ALL 3'' ST. 90'S NEED TO BE CHANGED . REFER TO P-706.3 TABLE WENT BACK @ 2: 41
DEMOLITION 08/13/2025 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH 08/13/2025 PARTIALLY APPROVED MGIBSON
Note: ALL 3'' ST. 90'S NEED TO BE CHANGED . REFER TO P-706.3 TABLE
ELECTRIC 1ST ROUGH 08/13/2025 APPROVED - AS NOTED RMARTIN
Note: Island power
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/03/2025 APPROVED JMUNSON

Review History

Department Status Date In Date Out
BLD COMPLETE 01/19/2026 01/20/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/29/2025 11/10/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/15/2025 10/20/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 10/08/2025 10/08/2025
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Foundation survey = foundation survey please label the document and file name the same
PLENG COMPLETE 10/08/2025 10/09/2025
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
DSD COMPLETE 02/24/2025 02/25/2025
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
FI1 COMPLETE 02/24/2025 03/10/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 02/24/2025 03/03/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 02/24/2025 03/06/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ARCHR COMPLETE 02/24/2025 03/10/2025
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
BLD COMPLETE 02/24/2025 03/06/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Plan Sheet LS1 6. Revise Occupant Protection section of chart to include required fire-resistive rating for the floor-ceiling assemblies based on VA construction type. Table lists “ceilings” only. The assembly type is floor – not ceiling. FBC 420.3, 711, 602, Table 601. Does your design include complete fire-resistive construction details for floor assemblies? 7. Revise Occupant Protection section of chart to include required fire-resistive rating for the roof-ceiling assemblies based on VA construction type. Table lists “ceilings” only. Roofs fire-resistive rating must be shown for roofs. FBC 602, Table 601. Does your design include complete fire-resistive construction details for the roof assemblies? Your letter references responses to the points above made to Plan Sheet A5, but not A5 was uploaded. Please upload page A5.
BADMIN INFORMATION 02/21/2025 02/21/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please correct your file names Excerpt from the Document Submittal Requirements posted on the permit portal page. 1. Files should be attached to the correct document type. 2. Files are to be submitted individually and named as identified in the examples below. (Exceptions: energy calculations, aluminum design plans, calculations, items where single pages cannot be altered.) 3. Plan sheets should be easily identifiable for the plans examiner to identify the type design discipline on the page. 4. Revisions and corrections should follow the same criteria and should use the same name as originally identified. DO NOT add anything to the beginning of the file name, you add to the file name following our required naming convention. (Examples of what NOT to do: Smith Residence – final survey, or 123 Main Street – landscape plan) • Boundary Survey = Boundary survey • Color and material = color and material sheet • Construction lien law = lien law • Electrical Calculations = electrical calcs • Elevation certificate= elevation cert • Energy calculations = energy calcs • Final Survey = final survey
ARCHR HOLD 12/11/2024 12/27/2024
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Provide Exterior Color schedule for all facades. Rever to LDC Section 13.02
BLD HOLD 12/11/2024 01/12/2025
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. General 1. Provide International Code Council (ICC) Evaluation Services Report (ESR) for engineered I-joists and rim-joist. All Architectural Plan Sheets 1. Provide architectural business firm qualifier number in title block. FS 481.221, FAC 61G1-16.004 Cover Sheet 1. Several plan sheets are not identified in the plan sheet index. Some appear to be mis-identified. For example Plan Sheet A-4 is identified as “Corridor Layout Building End Elevation” but most details relate to stair sections in plan view and cross section. There is a Building Elevation End View on A-4. Please at least identify the remaining plan sheets and clarify where needed. 2. Revise Third Party Special Inspector Note (fire penetrations) indicating the following: 1.) The inspector hired to perform quality assurance will be a Florida licensed Standard Building Inspector; 2.) A copy of the Inspectors license will be submitted to the Palm Coast Building Department prior to beginning inspection work, 3.) All through and membrane penetration fire-stop systems shall be submitted to the design professional in responsible charge for review and approval and shall be marked / stamped “approved” and when approved, copies submitted to the Palm Coast Building Department for review and approval. 4.) All through and membrane penetration fire-stop systems shall not be installed until approved by the Palm Coast Building Department. 3. Provide list of deferred submittals including guards, pre-manufactured stairs, roof trusses, attic scuttles, guards, stairs and other items not specifically mentioned herein. FBC 107. 3.4.1. Add notes indicating the following: 1.) All deferred submittals shall be designed, signed and sealed by a Florida licensed professional engineer 2.) All deferred submittals shall be submitted to the design professional in responsible charge for review and approval and shall be marked / stamped “approved” and when approved, copies submitted to the Palm Coast Building Department for review and approval. 3.) All deferred submittal items shall not be installed until approved by the Palm Coast Building Department. 4. Provide complete plan sheet index for all structural, plumbing and mechanical disciplines. How is the AHJ to know if it has received all plan sheets prepared by the various design professionals? As an alternative, each design professional may provide their own plan sheet index for their part of the design. AHJ. Plan Sheet LS1 1. Revise Occupant Load based on gross floor area of R-2 occupancy. See definition of “Gross Floor Area”, FBCB 202. Reference FBCB applicable sections and in particular FBCB 1004.1, Table 1004.5. Check remainder of means of egress details for compliance with the FBCB based on the increase in occupant load. 2. Provide total building design occupant load (total of all occupants). FBCB 1004.1 3. Provide cumulative occupant load at each means of egress convergence. FBCB 1004.2.3, 1005.6. 4. Change Building Height Section of table to Building Number of Stories. FBCB 504.4. 5. Add section for building height in feet. Show actual height in feet and allowable building height in feet. FBCB 504.3, Table 504.3. 6. Revise Occupant Protection section of chart to include required fire-resistive rating for the floor-ceiling assemblies based on VA construction type. Table lists “ceilings” only. The assembly type is floor – not ceiling. FBC 420.3, 711, 602, Table 601. Does your design include complete fire-resistive construction details for floor assemblies? 7. Revise Occupant Protection section of chart to include required fire-resistive rating for the roof-ceiling assemblies based on VA construction type. Table lists “ceilings” only. Roofs fire-resistive rating must be shown for roofs. FBC 602, Table 601. Does your design include complete fire-resistive construction details for the roof assemblies? 8. Revise Occupant Protection section to confirm dwelling unit separation walls are designed as smoke partitions in accordance with FBCB 708. FBCB 420.2 Plan Sheet A-4 1. Stair sections shall show required tread nosing curvature detail. FBCB 1011.5.5. 2. Stair section shows tread dimension of 11 inches but is not identified by verbiage like the risers. FBCB 1011.5.2. 3. Show maximum angle of stair risers not to exceed 30 degrees. FBCB 1011.5.5. 4. Show minimum headroom clearance of 80 inches. FBCB 1101.3 Plan Sheet DA2 1. I am having trouble reconciling the information shown on Plan Sheet DA2 and A-4. Details contain conflicting stair geometry design and information. Please reconcile or explain. 2. Add note indicating all handrails shall be returned to walls. Only the upper terminus of handrails are shown returned to walls. FBCB 1014.6. 3. Add note indicating handrails shall be provided on both sides of stairs. FBCB 1011.1. 4. Provide handrail profile and type. FBCB 1014.3 through 1014.3.2 All Structural Plan Sheets 1. Provide compliant digital seal on all structural plan sheets. FS Chapter 471, FAC 61G15-23.004. Digital seal appears to have been broken on the transfer of plan sheets to the City. Plan Sheet S1.0 1. Structural Design Criteria SDC-2 – provide concentrated loads for exits and stairs. FBCB 1607.4, Table 1607.1 Item No. 31, 1607.19. 2. Structural Design Criteria SDC-2 – provide live loads and concentrated loads for handrails, guards, grab bars and seats. FBCB 1607.9, 1607.9.1, 1607.9.1.1, 1607.9.2, Table 1607.1 Item No. 16. 3. Revise Foundation / Earthwork Note F-1 by referencing geotechnical investigation report prepared for this project. Report is by ValleyShore Engineering, Project No. 231057, dated September 12, 2023. Structural engineer has the right to use a lower soil bearing pressure of 1,500 psf where the report indicates 2,000 psf but the geotechnical investigation report must be referenced. FBCB 1803. 4. Revise Foundation / Earthwork Note F-3 to comply with minimum slope requirements perpendicular to all sides of the foundations. FBCB 1804.4. Note, this same requirement appears on the City approved Civil Engineering plans. Notes must agree with each other and conform to minimum FBCB requirements.
DSD COMPLETE 12/11/2024 12/30/2024
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
ELEC HOLD 12/11/2024 12/23/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Range and dryer need to be GFCI protected. NEC 2020 210.52
FI1 HOLD 12/11/2024 12/18/2024
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All plan review comments in this and other plan reviews shall be responded to in letter format signed and sealed by the registered design professionals responsible for addressing the comments. In addition, all plan sheets where revisions are made based on review comments shall be clouded indicating the presence of a plan revision. Only those plan sheets containing revisions shall be uploaded to the permit portal. Previous plan sheets replaced with new plan sheets will be “rejected” by the Building Division so as not to be printed or issued with the approved set of plans. DO NOT SUBMIT A FULL PLAN SET. 1. Plans submitted online must be digitally signed and sealed for review. http://docs.palmcoastgov.com/departments/building/online/digital-signatures.pdf 2. Please include the following code versions the plan sheets in the code analysis and anywhere they appear on the plans… NFPA 10, (2018) edition, Standard for Portable Fire Extinguishers NFPA 13R, (2019) edition, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies NFPA 72, (2019) edition, National Fire Alarm and Signaling Code 3. Plans submitted online must be digitally signed and sealed for review. http://docs.palmcoastgov.com/departments/building/online/digital-signatures.pdf 4. Please provide detail for Fire Fighter Safety Building Marking System per Florida Administrative Code 69A-3.012 and Florida Statutes 633.027 And place the following note on the cover sheet: Please call Fire Marshal, Randy Holmes at: 386-986-2303 for proper placement and verification of proper design and notification for the Fire Fighters Safety Building Marking System prior to placement. 5. Please place the following note on the plans. Water supply for fire protection must be made available and hydrants must be installed, completed, tested, and in service prior to storage of materials and or commencing construction on any structure per NFPA 1 16.5.3.1.1 and NFPA 1, 16.5.3.1.3 6. Please show the required extinguishers in each dwelling unit and in all exception locations per FBC 8th edition (2023) 906.1 (1) through (6) 7. Please establish a written fire safety plan for safeguards during construction per 8th edition (2023) FFPC 1, 16.4.1.1, 16.4.1.2.(1) through (8), and NFPA 241 (2013). and FBCB Chapter 33. The plan, at a minimum, shall include details for fire extinguishers per FBCB Section 3309, means of egress per FBCB Section 3310, standpipes per Section 3311, and water supply for fire protection per FBCB Section 3313. The plan shall also address, at a minimum, housekeeping, on-site security, pre-fire planning, access for fire-fighting, stairs, standpipes and fire protection during construction. The plan is subject to review and approval by the Palm Coast Fire Marshal. 8. Please provide plans for the security fence during construction per FFPC 8th edition (2023) 1, 16.4.2.5.4 and the AHJ [241:7.2.5.4] Please use the following information to obtain a properly keyed Knox Padlock… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 9. Please provide engineering design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems. 10. Alarm device locations on alarm floor plans need to have 1 - line drawings and they need to match the fire alarm riser diagram per FBC 107.3 (or indicate deferred submittals). 11. Need to show all devices on the code plan per FBC 107.3 (or indicate deferred submittals). 12. Need to show riser diagram, floor plan, Design criteria, and layout for fire sprinklers per FBC 107.3 (or indicate deferred submittals). 13. Please provide Fire Alarm Riser Diagram and be certain the riser matches the 1 - line fire alarm floor plan drawings for device locations and types per FBC 107.3 (or indicate deferred submittals). 14. Please show the required Identification for stairways per FFPC 7th Edition (2020) 101: 7.2.2.5.4.1 (A) through (P) 15. Please show the required door locking arrangements per FFPC 7th Edition (2020) 101: section 30.2.2. 16. On the LS1 sheet you are showing NFPA 2018. Please change to the proper year of the FFPC 2023 8th edition 17. Please show the Travel distance from most remote locations, Travel Distance to an Exit on the LSP sheet LS1 Per FFPC 8th edition 101, section 14.2 and AHJ 18. Provide means to freeze protect the fire sprinkler riser per nfpa 13r section 6.7.2 19. Please provide location for the knox box for rapid entry access of fire department and if canopies will be installed please place a note on the cover sheet indicating canopies and or awnings will have a minimum clearance of 13ft. 6in along the access pathway per NFPA 1, 18.2.2.2, FFPC 1 - 18.2.3.4.1.2 and AHJ. and place the following information on the plans… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes 20. Please provide the location of the required Knox Box for the building per FFPC 8th edition (2023) 1, 16.4.4.2.1 [241:7.5.2.1] and place the following information on the plans… Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes Additional comments are likely after resubmittal.
GAS CANCEL 12/11/2024 12/23/2024
MECH HOLD 12/11/2024 12/26/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-MECHANICAL AND FLORIDA BUILDING CODE -ENERGY CONSERVATION. PLEASE NOTE, COMMENTS ARE BASED EITHER UPON MISSING PLAN SHEETS, INCOMPLETE INFORMATION ON SUBMITTED PLAN SHEETS AND / OR REQUESTED PLAN CORRECTIONS TO COMPLY WITH APPLICABLE CODES BASED ON INFORMATION PROVIDED ON SUBMITTED PLAN SHEETS. REVISIONS ADDRESSING EACH OF THE COMMENTS BELOW ARE REQUIRED AT TIME OF APPLICATION FOR BUILDING PERMIT. FAILURE TO ADDRESS ALL PLAN REVIEW COMMENTS PROVIDED DURING THIS CODE ASSESSMENT REVIEW WILL DELAY APPROVAL OF SUBMITTED PLANS AND ISSUANCE OF THE BUILDING PERMIT. PLEASE BE ADVISED, THIS CODE ASSESSMENT REVIEW IS PROVIDED AS A COURTESY BY THE PALM COAST BUILDING DIVISION AND IS INTENDED TO SOLVE PLAN REVIEW ISSUES PRIOR TO APPLICATION FOR BUILDING PERMIT. HOWEVER, THIS REVIEW SHOULD NOT BE CONSIDERED TO BE ALL INCLUSIVE. THE PALM COAST BUILDING DIVISION RESERVES THE RIGHT TO REQUIRE ADDITIONAL PLAN CORRECTIONS AND REVISIONS BASED ON THE PLAN SUBMITTAL MADE AT TIME OF APPLICATION FOR BUILDING PERMIT. 1. Plan page M1 Revise code year in mechanical notes. FBC 2023 2. Provide note on plan for dryer vents not to exceed 35 feet and provisions if over 35 feet 504.9.4.1-504.9.4.2 FBC Mechanical 3. Energy Calculations needs to have a design location of Daytona Beach (Not Melbourne) FBC Energy Conservation and AHJ
PLUM COMPLETE 12/11/2024 01/12/2025
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
UD1 COMPLETE 12/11/2024 12/12/2024
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/27/2026
FC IMPACT FEE EMS ¤768.00 08/12/2025
IMPACT FEE FIRE ¤10,428.24 08/12/2025
FC IMPACT FEE LAW ENFORCEMENT ¤2,664.00 08/12/2025
FC IMPACT FEE LIBRARY ¤3,336.00 08/12/2025
IMPACT FEE PARKS ¤43,872.24 08/12/2025
IMPACT FEE SCHOOL ¤32,640.00 08/12/2025
IMPACT FEE TRANSPORTATION ¤48,432.00 08/12/2025
SURCHARGE FS 533.721 ¤360.73 08/12/2025
SURCHARGE - FS 468.631 ¤541.10 08/12/2025
SITE PLAN 30 ¤30.00 08/12/2025
ADJUSTMENT 10% (¤4,008.13) 08/12/2025
ADMINISTRATIVE - COMMERCIAL ¤75.00 08/12/2025
INSPECTION COMMERCIAL ¤32,375.00 08/12/2025
INSPECTION - FIRE COMMERCIAL ¤1,156.25 08/12/2025
PLAN REVIEW - COMMERCIAL ¤6,475.00 08/12/2025
Fees Total Due: ¤0.00 Total Paid: ¤179,177.93